Cited by 42Systemic Lupus Erythematosus ResearchBlood Coagulation and Thrombosis MechanismsClinical Laboratory Practices and Quality Control

Mixing test specific cut‐off is more sensitive at detecting lupus anticoagulants than index of circulating anticoagulant

Moore, Gary W., Culhane, Aidan P., Daw, Christopher R., Noronha, Charlotte P., Kumano, Osamu·2016·Thrombosis Research

Abstract

Introduction Recent guidelines for lupus anticoagulant (LA) detection recommend mixing test interpretation with either a mixing test-specific cut-off (MTC) or index of circulating anticoagulant (ICA). Few studies directly compare efficacy of these approaches. We retrospectively applied MTC and ICA assessment to raw data of 350 LA-positive plasmas from non-anticoagulated patients to compare detection rates of inhibition.Materials and methods Screen and confirm dRVVT and dilute APTT assays were performed on undiluted plasma and 1:1 mixtures with normal pooled plasma. Samples were considered LA-positive if one or both screening test ratios were elevated and corrected by ≥10% with the confirmatory test. Mixing tests were assessed against locally derived cut-offs for MTC (dRVVT >1.13, dAPTT >1.15) and ICA (dRVVT >11.9%, dAPTT >13.2%).Results 105 of 350 (30%) were positive in dRVVT and dAPTT, 109/350 (31.1%) were dRVVT positive only and 136/350 were dAPTT positive only (38.9%), from undiluted plasma results. Of the 214 dRVVT positive plasmas, 53 (24.8%) were negative for inhibition by MTC and 65 (30.4%) negative by ICA. Of the 241 dAPTT positive plasmas, 48 (19.2%) were negative by MTC and 97 (40.2%) negative by ICA.Conclusion Whilst integrated testing often detects LA without mixing tests they are diagnostically useful in certain circumstances. Thus, it is valuable to maximise mixing test interpretation as the dilution can lead to false-negative results. These data on a large cohort of LA-positive plasmas reveal that, with the reagents and equipment employed, MTC is superior to ICA in detecting the in vitro inhibition of LA.

Integrity signals

Registry

Crossref · 10.1016/j.thromres.2016.01.019

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

1 of the 35 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Moore, G. W., Culhane, A. P., Daw, C. R., Noronha, C. P., & Kumano, O.
Affiliations
  • St Thomas' Hospital (GB)
  • Sysmex (Japan) (JP)
Corresponding author
Moore, Gary W.
Venue
Thrombosis Research
Publisher
Elsevier BV
Published
2016-03
Volume
139
Pages
98-101
ISSN
0049-3848 (ISSN-L)
OpenAlex
W2280036456
Cited by
42
References
35
Citations by year
2026: 1 · 2025: 3 · 2024: 6 · 2023: 6 · 2022: 4 · 2021: 3 · 2020: 2 · 2019: 5 · 2018: 3 · 2017: 6 · 2016: 3
FWCI
6.05
Type
journal article
Language
en
Open access
closed
Locations
  • Thrombosis Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
Keywords
lupus anticoagulant, mixing test, in vitro inhibition, false-negative results, anticoagulant screening, diagnostic sensitivity
MeSH terms
Blood Coagulation Tests, Humans, Immunoglobulins, Partial Thromboplastin Time, Lupus Coagulation Inhibitor, Antiphospholipid Syndrome

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review