Measuring the exhaled breath of a manikin and human subjects
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Due to scarcity of accurate information and available data of actual human breathing, this investigation focuses on characterizing the breathing dynamic process based on the measurement of healthy human subjects. The similarities and differences between one breathing thermal manikin and the human subjects, including geometry and breathing functions, were thoroughly studied. As expected, actual human breathing is more complicated than that of the manikin in terms of airflow fluctuations, individual differences, and exhaled flow directions. The simplification of manikin mouth structure could result in overestimated exhaled velocity and contaminant concentration. Furthermore, actual human breathing appears to be relatively stable and reproducible for an individual person in several conditions and is also accompanied by some uncertainties simultaneously. The averaged values are used to analyze the overall characteristics of actual human breathing. There are different characteristics of the exhaled breath between male and female subjects with or without wearing a nose clip. The experimental results obtained from the measurement of human subjects may be helpful for manikin specification or validation and accuracy assessment of CFD simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 1×
“Papineni and Rosenthal (1997) even found higher concentration of droplets (>1 lm) from mouth breathing than coughing in one test subject.”
BackgroundMilton, D. K., Fabian, M. P., Cowling, B. J., Grantham, M. L., & McDevitt, J. J. (2013) · PLoS Pathogens · doi:10.1371/journal.ppat.1003205 · Cited by 669
Influenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496 · cited 1×
“…al., 2009; Chao et al., 2009; Redrow et al., 2011) have thoroughly studied coughing and sneezing that are generally considered of higher infectious risk, while some influenza viruses have been found present in human breathing (Fabian et al., 2008; Milton et al., 2013; Stelzer-Braid et al., 2009).”
BackgroundBjørn, E., & Nielsen, P. V. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.08126.x · Cited by 294 · cited 5×
“The manikins are used to explore the role of human respiratory behavior in the spreading of infectious disease between occupants (Bjørn and Nielsen, 2002; Brohus and Nielsen, 1996; Nielsen et al., 2007, 2008, 2010; Olmedo et al., 2012, 2013; Qian et al., 2006, 2008).”
BackgroundMethodResultInfluentialSelf-citationExhalation of respiratory viruses by breathing, coughing, and talking
Stelzer‐Braid, S., Oliver, B. G., Blazey, A. J., Argent, E., Newsome, T. P., Rawlinson, W. D., & Tovey, E. R. (2009) · Journal of Medical Virology · doi:10.1002/jmv.21556 · Cited by 165 · cited 2×
“…al., 2009; Chao et al., 2009; Redrow et al., 2011) have thoroughly studied coughing and sneezing that are generally considered of higher infectious risk, while some influenza viruses have been found present in human breathing (Fabian et al., 2008; Milton et al., 2013; Stelzer-Braid et al., 2009).”
BackgroundEffect of breathing route on ventilation and ventilatory drive
Douglas, N. J., White, D. P., Weil, J. V., & Zwillich, C. W. (1983) · Respiration Physiology · doi:10.1016/0034-5687(83)90041-5 · Cited by 74 · cited 1×
“Douglas et al. (1983) found varying respiratory frequency (RF) between nasal and mouth breathing.”
Background
Cited by
Simulating human exposure to indoor airborne microplastics using a Breathing Thermal Manikin
Vianello, A., Jensen, R. L., Liu, L., & Vollertsen, J. (2019) · Scientific Reports · doi:10.1038/s41598-019-45054-w · Cited by 766
Self-citationShort-range airborne route dominates exposure of respiratory infection during close contact
Chen, W., Zhang, N., Wei, J., Yen, H.-L., & Li, Y. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106859 · Cited by 371
Tang, J. W., Bahnfleth, W. P., Bluyssen, P. M., Buonanno, G., Jimenez, J. L., Kurnitski, J., Li, Y., Miller, S., Sekhar, C., Morawska, L., et al. (2021) · Journal of Hospital Infection · doi:10.1016/j.jhin.2020.12.022 · Cited by 350
Self-citationSpeech can produce jet-like transport relevant to asymptomatic spreading of virus
Abkarian, M., Mendez, S., Xue, N., Yang, F., & Stone, H. A. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2012156117 · Cited by 219
“5 m/s (23) (22, 24–28) Peak Reynolds numbers 7× 102 to 3× 103 1× 103 to 7× 103”
Indoor Aerosol Science Aspects of SARS-CoV-2 Transmission
Nazaroff, W. W. (2022) · Indoor Air · doi:10.1111/ina.12970 · Cited by 70
Metadata
- Authors
- Xu, C., Nielsen, P. V., Gong, G., Liu, L., & Jensen, R. L.
- Venue
- Indoor Air
- Publisher
- Wiley
- Published
- 2014-06-21
- Volume
- 25
- Issue
- 2
- Pages
- 188-197
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2144809659
- Cited by
- 97
- References
- 7
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring the exhaled breath of a manikin and human subjects. https://app.cochat.ai/papers/10.1111/ina.12129
- The paper
- Xu, C., Nielsen, P. V., Gong, G., Liu, L., & Jensen, R. L. (2015). Measuring the exhaled breath of a manikin and human subjects. Indoor Air. https://doi.org/10.1111/ina.12129
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.