The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Effects of exposure to carbon dioxide and bioeffluents on perceived air quality, self-assessed acute health symptoms, and cognitive performance
Open accessAbstract
The purpose of this study was to examine the effects on humans of exposure to carbon dioxide (CO2) and bioeffluents. In three of the five exposures, the outdoor air supply rate was high enough to remove bioeffluents, resulting in a CO2 level of 500 ppm. Chemically pure CO2 was added to this reference condition to create exposure conditions with CO2 at 1000 or 3000 ppm. In two further conditions, the outdoor air supply rate was restricted so that the bioeffluent CO2 reached 1000 or 3000 ppm. The same 25 subjects were exposed for 255 min to each condition. Subjective ratings, physiological responses, and cognitive performance were measured. No statistically significant effects on perceived air quality, acute health symptoms, or cognitive performance were seen during exposures when CO2 was added. Exposures to bioeffluents with CO2 at 3000 ppm reduced perceived air quality; increased the intensity of reported headache, fatigue, sleepiness, and difficulty in thinking clearly; and reduced speed of addition, the response time in a redirection task, and the number of correct links made in the cue-utilization test. This suggests that moderate concentrations of bioeffluents, but not pure CO2, will result in deleterious effects on occupants during typical indoor exposures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binary Codes capable of currecting deletions, insertions, and reversals
Levenshtein, V. I. (1965) · Soviet physics. Doklady · Cited by 14,807
The global burden of asthma: executive summary of the GINA Dissemination Committee Report
Masoli, M., Fabian, D., Holt, S., Beasley, R., & Program, G. I. F. A. (. (2004) · Allergy · doi:10.1111/j.1398-9995.2004.00526.x · Cited by 3,529
Subjective and objective sleepiness in the active individual
Åkerstedt, T., & Gillberg, M. (1990) · International Journal of Neuroscience · doi:10.3109/00207459008994241 · Cited by 3,088
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064 · cited 3×
“…fatigue, eye, nose and respiratory tract symptoms even in buildings where CO 2 levels were below 5,000 ppm; the prevalence of symptoms continued to decrease with the CO 2 level even below 800 ppm (e.g., Myhrvold et al., 1996; Seppänen et al., 1999; Tsai et al., 2012; Norbäck et al., 2013).”
BackgroundAllen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1510037 · Cited by 977 · cited 10×
“(2012) and Allen et al. (2015), known as the Strategic Management Simulation (SMS) (Streufert et al.”
BackgroundMethodResultInfluentialSeppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876 · cited 2×
“…fatigue, eye, nose and respiratory tract symptoms even in buildings where CO 2 levels were below 5,000 ppm; the prevalence of symptoms continued to decrease with the CO 2 level even below 800 ppm (e.g., Myhrvold et al., 1996; Seppänen et al., 1999; Tsai et al., 2012; Norbäck et al., 2013).”
BackgroundDocumentation of the Threshold Limit Values and Biological Exposure Indices
Acgih (2001) · Medical Entomology and Zoology · Cited by 845
WARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Self-citationImpact of Temperature and Humidity on the Perception of Indoor Air Quality
Fang, L., Clausen, G., & Fanger, P. O. (1998) · Indoor Air · doi:10.1111/j.1600-0668.1998.t01-2-00003.x · Cited by 534
Wargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507
Self-citationThe psychological significance of the concept of "arousal" or "activation."
Duffy, E. (1957) · Psychological Review · doi:10.1037/h0048837 · Cited by 490
Wisthaler, A., & Weschler, C. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904498106 · Cited by 444
Quantitative measurement of productivity loss due to thermal discomfort
Lan, L., Wargocki, P., & Lian, Z. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2010.09.001 · Cited by 442
Self-citationFanger, P. O. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90051-5 · Cited by 371
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Lan, L., & Lian, Z. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.11.002 · Cited by 360
Self-citationAPTE, M. G., FISK, W. J., & DAISEY, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341
Association between substandard classroom ventilation rates and students’ academic achievement
Haverinen-Shaughnessy, U., Moschandreas, D. J., & Shaughnessy, R. J. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00686.x · Cited by 311
Providing better thermal and air quality conditions in school classrooms would be cost-effective
Wargocki, P., & Wyon, D. P. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.10.007 · Cited by 309
Self-citationMendell, M. J., Eliseeva, E. A., Davies, M. M., Spears, M., Lobscheid, A., Fisk, W. J., & Apte, M. G. (2013) · Indoor Air · doi:10.1111/ina.12042 · Cited by 299
Proceedings of Healthy Buildings
Brohus, H. (2006) · Cited by 249
Shaughnessy, R. J., Haverinen-Shaughnessy, U., Nevalainen, A., & Moschandreas, D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00440.x · Cited by 230
Ventilation rates in the bedrooms of 500 Danish children
Bekö, G., Lund, T., Nors, F., Toftum, J., & Clausen, G. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.04.014 · Cited by 209
State-of-the-art review of CO2 demand controlled ventilation technology and application
Emmerich, S. J., & Persily, A. K. (2001) · doi:10.6028/nist.ir.6729 · Cited by 208
Clements-Croome, D. J., Awbi, H. B., Bakó-Biró, Z., Kochhar, N., & Williams, M. (2008) · Building and Environment · doi:10.1016/j.buildenv.2006.03.018 · Cited by 203
Fang, L., Clausen, G., & Fanger, P. O. (1998) · Indoor Air · doi:10.1111/j.1600-0668.1998.00008.x · Cited by 202
Partington, J. E., & Leiter, R. G. (2020) · PsycTESTS Dataset · doi:10.1037/t66320-000 · Cited by 194
Ozone-Initiated Chemistry in an Occupied Simulated Aircraft Cabin
Weschler, C. J., Wisthaler, A., Cowlin, S., Tamás, G., Strøm-Tejsen, P., Hodgson, A. T., Destaillats, H., Herrington, J., Zhang, J. (., & Nazaroff, W. W. (2007) · Environmental Science & Technology · doi:10.1021/es0708520 · Cited by 185
Adaptation to indoor air pollution
Gunnarsen, L., & Fanger, P. O. (1992) · Environment International · doi:10.1016/0160-4120(92)90209-m · Cited by 165
Zhang, X., Wargocki, P., & Lian, Z. (2017) · Indoor Air · doi:10.1111/ina.12286 · Cited by 164
Self-citationMaddalena, R. L., Mendell, M. J., Eliseeva, K., Chan, W. R., Sullivan, D. P., Russell, M., Satish, U., & Fisk, W. J. (2014) · Indoor Air · doi:10.1111/ina.12149 · Cited by 153
Office Workers’ Sick Building Syndrome and Indoor Carbon Dioxide Concentrations
Tsai, D.-H., Lin, J.-S., & Chan, C. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.675291 · Cited by 149
Association of carbon dioxide with indoor air pollutants and exceedance of health guideline values
Ramalho, O., Wyart, G., Mandin, C., Blondeau, P., Cabanes, P., Leclerc, N., Mullot, J., Boulanger, G., & Redaelli, M. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.018 · Cited by 143
Twardella, D., Matzen, W., Lahrz, T., Burghardt, R., Spegel, H., Hendrowarsito, L., Frenzel, A. C., & Fromme, H. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00774.x · Cited by 139
Wargocki, P. L., Wyon, D. P., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00304.x · Cited by 137
Self-citationSârbu, I., & Păcurar, C. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.06.022 · Cited by 123
Ventilation requirements in buildings—I. Control of occupancy odor and tobacco smoke odor
Cain, W. S., Leaderer, B. P., Isseroff, R., Berglund, L. G., Huey, R. J., Lipsitt, E. D., & Perlman, D. (1983) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(83)90341-4 · Cited by 112
Automated mixed ANOVA modeling of sensory and consumer data
Kuznetsova, A., Christensen, R. H. B., Bavay, C., & Brockhoff, P. B. (2014) · Food Quality and Preference · doi:10.1016/j.foodqual.2014.08.004 · Cited by 110
SIMULATION‐BASED ASSESSMENT OF MANAGERIAL COMPETENCE: RELIABILITY AND VALIDITY
Streufert, S., Pogash, R. M., & Piasecki, M. T. (1988) · Personnel Psychology · doi:10.1111/j.1744-6570.1988.tb00643.x · Cited by 97
Erdmann, C. A., Steiner, K. C., & Apte, M. G. (2002) · University of North Texas Digital Library (University of North Texas) · Cited by 89
Norbäck, D., Nordström, K., & Zhao, Z. (2012) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-012-0756-6 · Cited by 71
Korver, W. O. E. (2001) · Elsevier eBooks · doi:10.1016/b978-0-8155-1449-7.50011-6 · Cited by 68
Sensory pollution sources in buildings
Wargocki, P. L. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00277.x · Cited by 63
Self-citationIndoor environment and pupils' health in primary schools
van Dijken, F., Bronswijk, J. E. M. H. V., & Sundell, J. (2006) · Building Research & Information · doi:10.1080/09613210600735851 · Cited by 57
How Indoor Environment Affects Performance
Wyon, D. P., & Wargocki, P. L. (2013) · Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) · Cited by 51
Self-citationSatish, U., Streufert, S. C., Dewan, M. J., & Voort, S. V. (2004) · Allergy · doi:10.1046/j.1398-9995.2003.00360.x · Cited by 37
Pupils health and performance due to renovation of schools
Myhrvold, A. (1997) · Medical Entomology and Zoology · Cited by 31
Cue Utilization as a Function of Drive: An Experimental Study
Eysenck, H. J., & Willett, R. A. (1962) · Perceptual and Motor Skills · doi:10.2466/pms.1962.15.1.229 · Cited by 24
Tham, K. W., & Fadeyi, M. O. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.10.014 · Cited by 14
Cited by
Tran, V. V., Park, D., & Lee, Y.-C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17082927 · Cited by 822
Direct human health risks of increased atmospheric carbon dioxide
Jacobson, T. A., Kler, J. S., Hernke, M. T., Braun, R. K., Meyer, K. C., & Funk, W. E. (2019) · Nature Sustainability · doi:10.1038/s41893-019-0323-1 · Cited by 609
Carbon dioxide generation rates for building occupants
Persily, A., & de Jonge, L. (2017) · Indoor Air · doi:10.1111/ina.12383 · Cited by 566
Azuma, K., Kagi, N., Yanagi, U., & Osawa, H. (2018) · Environment International · doi:10.1016/j.envint.2018.08.059 · Cited by 403
Kumar, P., Singh, A. B., Arora, T., Singh, S., & Singh, R. (2023) · Science of The Total Environment · doi:10.1016/j.scitotenv.2023.162163 · Cited by 380
Metadata
- Authors
- Zhang, X., Wargocki, P., Lian, Z., & Thyregod, C.
- Venue
- Indoor Air
- Publisher
- Wiley
- Published
- 2016-03-07
- Volume
- 27
- Issue
- 1
- Pages
- 47-64
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2268369868
- Cited by
- 360
- References
- 51
- FWCI
- 11.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.