Evaluation of the Airtraq ® and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation*
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Summary: The Airtraq ® , a novel single use indirect laryngoscope, has demonstrated promise in the normal and simulated difficult airway. We compared the ease of intubation using the Airtraq with the Macintosh laryngoscope, in patients at increased risk for difficult tracheal intubation, in a randomised, controlled clinical trial. Forty consenting patients presenting for surgery requiring tracheal intubation, who were deemed to possess at least three characteristics indicating an increased risk for difficulty in tracheal intubation, were randomly assigned to undergo tracheal intubation using a Macintosh ( n = 20) or Airtraq ( n = 20) laryngoscope. All patients were intubated by one of three anaesthetists experienced in the use of both laryngoscopes. Four patients were not successfully intubated with the Macintosh laryngoscope, but were intubated successfully with the Airtraq. The Airtraq reduced the duration of intubation attempts (mean (SD); 13.4 (6.3) vs 47.7 (8.5) s), the need for additional manoeuvres, and the intubation difficulty score (0.4 (0.8) vs 7.7 (3.0)). Tracheal intubation with the Airtraq also reduced the degree of haemodynamic stimulation and minor trauma compared to the Macintosh laryngoscope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471
A clinical sign to predict difficult tracheal intubation; a prospective study
Mallampati, S. R., Gatt, S. P., Gugino, L. D., Desai, S. P., Waraksa, B., Freiberger, D., & Liu, P. L. (1985) · Canadian Anaesthetists’ Society Journal · doi:10.1007/bf03011357 · Cited by 2,450
Difficult Airway Society guidelines for management of the unanticipated difficult intubation
Henderson, J. J., Popat, M. T., Latto, I. P., & Pearce, A. C. (2004) · Anaesthesia · doi:10.1111/j.1365-2044.2004.03831.x · Cited by 1,025 · cited 1×
“In the event that neither device resulted in successful tracheal intubation, the standard Difficult Airway Society failed Intubation algorithm [ 12 ] was followed.”
MethodAdnet, F., Borron, S. W., Racine, S. X., Clemessy, J.-L., Fournier, J.-L., Plaisance, P., & Lapandry, C. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00005 · Cited by 703
CARDIOVASCULAR AND CATECHOLAMINE RESPONSES TO LARYNGOSCOPY WITH AND WITHOUT TRACHEAL INTUBATION
SHRIBMAN, A. J., SMITH, G., & ACHOLA, K. J. (1987) · British Journal of Anaesthesia · doi:10.1093/bja/59.3.295 · Cited by 619 · cited 1×
“However, laryngoscopy alone has been demonstrated to produce similar increases in plasma adrenaline and noradrenaline to that seen with laryngoscopy followed by tracheal intubation [ 16 ].”
ResultTse, J. C., Rimm, E. B., & Hussain, A. (1995) · Anesthesia & Analgesia · doi:10.1097/00000539-199508000-00008 · Cited by 234 · cited 1×
“Unfortunately, despite predictive tests such as the Mallampatti classification, mouth opening, and thyromental distance, no single factor reliably predicts these difficulties [ 13 ].”
BackgroundMaharaj, C. H., Buckley, E., Harte, B. H., & Laffey, J. G. (2007) · Anesthesiology · doi:10.1097/01.anes.0000267529.71756.f0 · Cited by 192
Self-citationLewis, M., Keramati, S., Benumof, J. L., & Berry, C. C. (1994) · Anesthesiology · doi:10.1097/00000542-199407000-00011 · Cited by 138 · cited 1×
“Interincisor distance was measured with the patient in the sitting position, and thyromental distance was measured from inside of the mentum to the thyroid cartilage with the head in full extension [ 10 ].”
MethodThe Airtraq ® as a rescue airway device following failed direct laryngoscopy: a case series
Maharaj, C. H., Costello, J. F., McDonnell, J. G., Harte, B. H., & Laffey, J. G. (2007) · Anaesthesia · doi:10.1111/j.1365-2044.2007.05036.x · Cited by 100 · cited 3×
“Data relating to four of the patients included in this study that were not successfully intubated with the Macintosh laryngoscope have previously been published as part of a series of cases of failed tracheal intubations rescued with the Airtraq laryngoscope [ 8 ].”
BackgroundResultInfluentialSelf-citationLim, Y., Lim, T. J., & Liu, E. H. C. (2004) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03018415 · Cited by 58 · cited 1×
“Similarresults tothoseseenwith the Airtraq have been demonstrated with other indirect laryngoscopes, such as the GlideScope [ 21 ] and video optical stylet [22].”
MethodA comparison of two techniques for inserting the Airtraq ™ laryngoscope in morbidly obese patients
Dhonneur, G., Ndoko, S. K., Amathieu, R., Attias, A., Housseini, L. E., Polliand, C., & Tual, L. (2007) · Anaesthesia · doi:10.1111/j.1365-2044.2007.05128.x · Cited by 53
Emergency use of the Airtraq laryngoscope in traumatic asphyxia: case report
Black, J. J. (2007) · Emergency Medicine Journal · doi:10.1136/emj.2006.040469 · Cited by 30 · cited 2×
“Recent reports have highlighted the utility of the Airtraq in a number of difficult airway settings, including post traumatic asphyxia [ 6 ], in morbid obesity [7], and following failed conventional approaches to tracheal intubation [8].”
Background
Cited by
Mushambi, M. C., Kinsella, S. M., Popat, M., Swales, H., Ramaswamy, K. K., Winton, A. L., & Quinn, A. C. (2015) · Anaesthesia · doi:10.1111/anae.13260 · Cited by 608
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Aziz, M. F., Dillman, D., Fu, R., & Brambrink, A. M. (2012) · Anesthesiology · doi:10.1097/aln.0b013e318246ea34 · Cited by 352
Malik, M. A., Subramaniam, R., Maharaj, C. H., Harte, B. H., & Laffey, J. G. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep266 · Cited by 163
Self-citation
Metadata
- Authors
- Maharaj, C. H., Costello, J. F., Harte, B. H., & Laffey, J. G.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2008-01-16
- Volume
- 63
- Issue
- 2
- Pages
- 182-188
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2165965178
- Cited by
- 186
- References
- 13
- FWCI
- 31.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.