CoChat

A quantitative review and meta‐analysis of performance of non‐standard laryngoscopes and rigid fibreoptic intubation aids

Mihai, R., Blair, E., Kay, H., Cook, T. M. · 2008 · Anaesthesia
Cited by 179

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Abstract

Summary: This quantitative review summarises studies of rigid fibreoptic laryngoscopy systems. In 6622 ‘normal’ patients only the Bonfils and CTrach had homogenous data and first time intubation success rates above 90%. In 1110 patients predicted or known to be difficult to intubate only the Bonfils, CTrach and Glidescope had homogenous data and first‐time success rates above 90%. In comparative studies with the Macintosh‐3 blade, no device had homogenous data in more than one study. Many devices had higher summed performances, but due to data heterogeneity, interpretation is very difficult, if worthwhile at all. The currently available data do not provide strong evidence that these devices should supersede standard direct laryngoscopy for routine or difficult intubation. Further research needs to be of high quality, studying relevant patients to create such evidence. Multicentre collaborations are likely to be needed studying known difficult patients or creating databases reporting the success/failure rate of these devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2044.2008.05489.x

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

Metadata

Authors
Mihai, R., Blair, E., Kay, H., & Cook, T. M.
Venue
Anaesthesia
Publisher
Wiley
Published
2008-06-10
Volume
63
Issue
7
Pages
745-760
ISSN
  • 0003-2409 (ISSN-L)
  • 1365-2044
OpenAlex
W1535762044
Cited by
179
References
37
FWCI
24.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.