CoChat

The distribution of melanin in skin determined in vivo

Matts, P.J., Dykes, P.J., Marks, R. · 2007 · British Journal of Dermatology
Cited by 95

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: There continues to be a need for objective, noninvasive methods to measure melanin concentration in vivo in human skin, independent of the confounding chromophore, haemoglobin. Existing methods are limited by a lack of specificity and inability to resolve the spatial distribution of these chromophores. OBJECTIVES: To validate and calibrate the measurement of eumelanin in vivo using SIAscopic techniques, relating this with histologically and analytically determined eumelanin concentrations in nonsun-exposed skin from subjects of Fitzpatrick skin types I-VI. METHODS: Observations were made in five subjects from each of the Fitzpatrick skin types I-VI using chromophore mapping by contact and noncontact SIAscopy and other noninvasive spectrophotometric means. Measurements were performed on the inner aspect of both upper arms. Subsequently two 4 mm punch biopsies were taken from the inner upper arm, one per arm after injection of local anaesthesia. One biopsy was fixed in formalin and processed for histology; specifically, sections were stained for melanin using a silver staining technique and the amount of melanin was graded microscopically. The other biopsy was subjected to an analytical assay to yield precise quantitative measures of melanin. The correlation between the different methods of melanin measurement was determined. RESULTS: Clear, significant correlations were obtained between contact and noncontact SIAscope-derived eumelanin values and actual eumelanin tissue content (determined both histologically and analytically), across the full range of Fitzpatrick skin types. There was no correlation between SIAscope-derived eumelanin and haemoglobin values, indicating efficient separation of the two chromophores. CONCLUSIONS: New contact and noncontact chromophore SIAscopic mapping techniques provide robust, rapid noninvasive measures of the concentration and spatial distribution of eumelanin in vivo, independent of haemoglobin, which correspond to true tissue values for this chromophore.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2133.2006.07706.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 95

Metadata

Authors
Matts, P. J., Dykes, P. J., & Marks, R.
Venue
British Journal of Dermatology
Published
2007-04
Volume
156
Issue
4
Pages
620-628
ISSN
  • 0007-0963 (ISSN-L)
  • 1365-2133
OpenAlex
W2076187744
Cited by
95
References
3
FWCI
2.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.