A critical evaluation of cryoprecipitate for replacement of fibrinogen
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
Summary: Maintaining the plasma fibrinogen concentration is important to limit excessive perioperative blood loss. This article considers the evidence for this statement, and questions the justification for using cryoprecipitate rather than virus‐inactivated fibrinogen concentrate to support plasma fibrinogen levels. Haemophilia was historically treated with cryoprecipitate, but specific coagulation factor concentrates are now preferred. In contrast, primary fractions of allogeneic donor blood, including cryoprecipitate, are still commonly used to treat perioperative bleeding. When compared with cryoprecipitate and fresh‐frozen plasma (FFP), freeze‐dried fibrinogen concentrate offers standardized fibrinogen content, faster reconstitution and improved efficacy. Pasteurization and purification processes employed in the preparation of fibrinogen concentrate reduce the risk of pathogen transmission and immune‐mediated complications, in comparison with cryoprecipitate and FFP. When all costs associated with administration are taken into consideration, the cost of fibrinogen concentrate is not substantially different to that of cryoprecipitate. In conclusion, wider availability and use of fibrinogen concentrate may improve the management of perioperative bleeding. Further benefits may accrue from more rapid and accurate techniques for monitoring fibrinogen levels. Clinical studies are needed to evaluate methods of measuring fibrinogen and assessing fibrin polymerization, and to define critical haemostatic plasma fibrinogen concentrations in different perioperative situations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thromboelastography-Guided Transfusion Algorithm Reduces Transfusions in Complex Cardiac Surgery
Shore-Lesserson, L., Manspeizer, H. E., DePerio, M., Francis, S., Vela-Cantos, F., & Ergin, M. A. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199902000-00016 · Cited by 845 · cited 1×
“Certainly, evidence is growing that haemostasis management guided by thromboelastographic techniques is associated with a lower requirement for allogeneic transfusions (Shore-Lesserson et al, 1999; Royston & von Kier, 2001; Kozek-Langenecker, 2007; Spalding et al, 2007).”
BackgroundGuidelines for the use of fresh‐frozen plasma, cryoprecipitate and cryosupernatant
British Committee for Standards in Haematology, B. T. T. F. (. D., O'Shaughnessy, D. F., Atterbury, C., Bolton Maggs, P., Murphy, M., Thomas, D., Yates, S., & Williamson, L. M. (2004) · British Journal of Haematology · doi:10.1111/j.1365-2141.2004.04972.x · Cited by 840
The decrease of fibrinogen is an early predictor of the severity of postpartum hemorrhage
CHARBIT, B., MANDELBROT, L., SAMAIN, E., BARON, G., HADDAOUI, B., KEITA, H., SIBONY, O., MAHIEU‐CAPUTO, D., HURTAUD‐ROUX, M. F., HUISSE, M. G., et al. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02297.x · Cited by 762 · cited 3×
“Thus, the threshold level for treatment may be substantially higher than the ‘historical’ 1 g/l, particularly in patients suffering from postpartum bleeding [4 g/l; (Charbit et al, 2007)] or excessive blood loss during cardiac surgery [3Æ8 g/l; (Karlsson et al, 2008)].”
BackgroundHemostatic Factors and Replacement of Major Blood Loss with Plasma-Poor Red Cell Concentrates
Hiippala, S. T., Myllyla, G. J., & Vahtera, E. M. (1995) · Anesthesia & Analgesia · doi:10.1097/00000539-199508000-00026 · Cited by 703 · cited 1×
“However, in the modern era of intravenous fluids and red cell concentrates, fibrinogen deficiency was the first defect observed (Hiippala et al, 1995).”
BackgroundPool, J. G., & Shannon, A. E. (1965) · New England Journal of Medicine · doi:10.1056/nejm196512302732701 · Cited by 423 · cited 1×
“This was followed by the development of cryoprecipitate (Pool et al, 1964; Pool & Shannon, 1965), which allowed an effective dose of factor VIII in a tolerable volume and led to a dramatic increase in life expectancy (Josephson & Abshire, 2006).”
MethodStinger, H. K., Spinella, P. C., Perkins, J. G., Grathwohl, K. W., Salinas, J., Martini, W. Z., Hess, J. R., Dubick, M. A., Simon, C. D., Beekley, A. C., et al. (2008) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e318160a57b · Cited by 414 · cited 1×
“Cryoprecipitate contains a higher concentration of fibrinogen than FFP, typically around 15 g/l (Stinger et al, 2008).”
BackgroundGuidelines on the management of massive blood loss
British Committee for Standards in Haematology, Stainsby, D., MacLennan, S., Thomas, D., Isaac, J., & Hamilton, P. J. (2006) · British Journal of Haematology · doi:10.1111/j.1365-2141.2006.06355.x · Cited by 393 · cited 1×
“Although fibrinogen levels of around 1 g/l are widely cited as a threshold for triggering supplementation, dating back to the late 1980s (Ciavarella et al, 1987), the optimal value for this is not clear (O’Shaughnessy et al, 2004; Stainsby et al, 2006).”
BackgroundChowdhury, P., Saayman, A. G., Paulus, U., Findlay, G. P., & Collins, P. W. (2004) · British Journal of Haematology · doi:10.1111/j.1365-2141.2004.04868.x · Cited by 381 · cited 1×
“There is a clear consensus that treatment with FFP is inappropriate in cases of severe fibrinogen deficiency as it contains insufficient concentrations of fibrinogen (Chowdhury et al, 2004; Danes et al, 2008).”
BackgroundThe hazards of blood transfusion in historical perspective
Alter, H. J., & Klein, H. G. (2008) · Blood · doi:10.1182/blood-2008-07-077370 · Cited by 374 · cited 5×
“Assays to screen blood for contamination with HIV were introduced in 1985, significantly reducing the risk of transfusion-transmitted HIV (Alter & Klein, 2008).”
BackgroundInfluentialChapman, C. E., Stainsby, D., Jones, H., Love, E., Massey, E., Win, N., Navarrete, C., Lucas, G., Soni, N., Morgan, C., et al. (2009) · Transfusion · doi:10.1111/j.1537-2995.2008.01948.x · Cited by 349
Cited by
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Görlinger, K., Dirkmann, D., Hanke, A. A., Kamler, M., Kottenberg, E., Thielmann, M., Jakob, H., & Peters, J. (2011) · Anesthesiology · doi:10.1097/aln.0b013e31823497dd · Cited by 426
Fibrinogen as a therapeutic target for bleeding: a review of critical levels and replacement therapy
Levy, J. H., Welsby, I., & Goodnough, L. T. (2014) · Transfusion · doi:10.1111/trf.12431 · Cited by 331
Cortet, M., Deneux-Tharaux, C., Dupont, C., Colin, C., Rudigoz, R.-C., Bouvier-Colle, M.-H., & Huissoud, C. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes096 · Cited by 305
Fibrinogen and Hemostasis: A Primary Hemostatic Target for the Management of Acquired Bleeding
Levy, J. H., Szlam, F., Tanaka, K. A., & Sniecienski, R. M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31822e1853 · Cited by 290
Rahe-Meyer, N., Solomon, C., Hanke, A., Schmidt, D. S., Knoerzer, D., Hochleitner, G., Sørensen, B., Hagl, C., & Pichlmaier, M. (2013) · Anesthesiology · doi:10.1097/aln.0b013e3182715d4d · Cited by 274
Self-citationKozek-Langenecker, S., Sørensen, B., Hess, J. R., & Spahn, D. R. (2011) · Critical Care · doi:10.1186/cc10488 · Cited by 234
“However, despite growing evidence based on both preclinical and clinical studies to support its efficacy and safety [17-20], fibrinogen concentrate is not yet a standard component of many transfusion protocols.”
BackgroundSelf-citationEarly and individualized goal-directed therapy for trauma-induced coagulopathy
Schöchl, H., Maegele, M., Solomon, C., Görlinger, K., & Voelckel, W. (2012) · Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine · doi:10.1186/1757-7241-20-15 · Cited by 218
“Cryoprecipitate, another source of fibrinogen, is still available in the US and the UK, but it has been withdrawn from some European countries in response to significant safety concerns [72].”
BackgroundMallaiah, S., Barclay, P., Harrod, I., Chevannes, C., & Bhalla, A. (2015) · Anaesthesia · doi:10.1111/anae.12859 · Cited by 213
Haemostatic monitoring during postpartum haemorrhage and implications for management
Solomon, C., Collis, R. E., & Collins, P. W. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes361 · Cited by 213
Nascimento, B., Goodnough, L. T., & Levy, J. H. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aeu158 · Cited by 208
Morrison, J. J., Ross, J. D., Dubose, J. J., Jansen, J. O., Midwinter, M. J., & Rasmussen, T. E. (2013) · JAMA Surgery · doi:10.1001/jamasurg.2013.764 · Cited by 204
“A unit of cryoprecipitate administered in this study was pooled from 10 donors with a fibrinogen concentration of around 15 g/L.(23) This is in contrast to fresh frozen plasma, which has a concentration of around 2.”
MethodManagement of Hemorrhage in Cardiothoracic Surgery
Görlinger, K., Shore-Lesserson, L., Dirkmann, D., Hanke, A. A., Rahe-Meyer, N., & Tanaka, K. A. (2013) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2013.05.014 · Cited by 165
Ahmed, S., Harrity, C., Johnson, S., Varadkar, S., McMorrow, S., Fanning, R., Flynn, C. M., O' Riordan, J. M., & Byrne, B. M. (2012) · Transfusion Medicine · doi:10.1111/j.1365-3148.2012.01178.x · Cited by 118
Metadata
- Authors
- Sørensen, B., & Bevan, D.
- Venue
- British Journal of Haematology
- Publisher
- Wiley
- Published
- 2010-05-20
- Volume
- 149
- Issue
- 6
- Pages
- 834-843
- ISSN
- 0007-1048 (ISSN-L)
- 1365-2141
- OpenAlex
- W2123086946
- Cited by
- 171
- References
- 55
- FWCI
- 11.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.