Scan speed limit in atomic force microscopy
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
SUMMARY: The scan speed limit of atomic force microscopes has been calculated. It is determined by the spring constant of the cantilever k, its effective mass m, the damping constant D of the cantilever in the surrounding medium and the stiffness of the sample. Techniques to measure k, k/m and D/m are described. In liquids the damping constant and the effective mass of the cantilever increase. A consequence of this is that the transfer function always depends on the scan speed when imaging in liquids. The practical scan speed limit for atomic resolution in vacuum is 0·1 μm/s while in water it increases to about 2 μm/s due to the additional damping of cantilever movements. Sample stiffness or damping of cantilever movements by the sample increase these limits. For soft biological materials imaged in water at a desired resolution of 1 nm the scan speed should not exceed 2 μm/s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
The Feynman Lectures on Physics
Feynman, R. P., Leighton, R. B., Sands, M., & Treiman, S. B. (1964) · Physics Today · doi:10.1063/1.3051743 · Cited by 2,939
Atomic-scale friction of a tungsten tip on a graphite surface
Mate, C. M., McClelland, G. M., Erlandsson, R., & Chiang, S. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.1942 · Cited by 1,763
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
Drake, B., Prater, C. B., Weisenhorn, A. L., Gould, S. A. C., Albrecht, T. R., Quate, C. F., Cannell, D. S., Hansma, H. G., & Hansma, P. K. (1989) · Science · doi:10.1126/science.2928794 · Cited by 1,033
Self-citationMicrofabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747 · cited 3×
“Spring constant and w, were calculated with an elasticity E of 1 5 x 10" N/ m2 and a density p, of 3000 kg/m3 (McMillan & Misra, 1970; Peterson, 1982; Albrecht et al., 1990; Meyer & Amer, 1990; Sarid & Elings. 1991).”
BackgroundMethodInfluentialRugar, D., & Hansma, P. (1990) · Physics Today · doi:10.1063/1.881238 · Cited by 589
Meyer, G., & Amer, N. M. (1990) · Applied Physics Letters · doi:10.1063/1.103950 · Cited by 587
Atomic-Resolution Electrochemistry with the Atomic Force Microscope: Copper Deposition on Gold
Manne, S., Hansma, P. K., Massie, J., Elings, V. B., & Gewirth, A. A. (1991) · Science · doi:10.1126/science.251.4990.183 · Cited by 411
Tip Surface Interactions in STM and AFM
Pethica, J. B., & Oliver, W. C. (1987) · Physica Scripta · doi:10.1088/0031-8949/1987/t19a/010 · Cited by 388
Micromachined silicon sensors for scanning force microscopy
Wolter, O., Bayer, T., & Greschner, J. (1991) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.585195 · Cited by 348
Harris, C. M., & Crede, C. E. (1976) · UCLA Biblioteca de Ingenieria Civil · Cited by 332
Combined scanning force and friction microscopy of mica
Marti, O., Colchero, J., & Mlynek, J. (1990) · Nanotechnology · doi:10.1088/0957-4484/1/2/003 · Cited by 310
Atomic-scale imaging of calcite growth and dissolution in real time
Hillner, P. E., Gratz, A. J., Manne, S., & Hansma, P. K. (1992) · Geology · doi:10.1130/0091-7613(1992)020<0359:asiocg>2.3.co;2 · Cited by 301 · cited 1×
“When processes are imaged (Drake et al., 1989; Manne et al., 1991; Delawski & Parkinson, 1992; Durbin & Carlson, 1992; Haberle et al., 1992; Hillner et al., 1992) the maximum scan speed limits the time resolution.”
BackgroundAtomic scale friction between the muscovite mica cleavage plane and a tungsten tip
Erlandsson, R., Hadziioannou, G., Mate, C. M., McClelland, G. M., & Chiang, S. (1988) · The Journal of Chemical Physics · doi:10.1063/1.455608 · Cited by 263
On the stability of a tip and flat at very small separations
Pethica, J. B., & Sutton, A. P. (1988) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.575577 · Cited by 263
Special Issue: Dynamics of Molecular Systems
Drake, J. M., & Klafter, J. (1990) · Physics Today · doi:10.1063/1.881259 · Cited by 254
Charge storage in a nitride-oxide-silicon medium by scanning capacitance microscopy
Barrett, R. C., & Quate, C. F. (1991) · Journal of Applied Physics · doi:10.1063/1.349388 · Cited by 245
Interaction forces of a sharp tungsten tip with molecular films on silicon surfaces
Blackman, G. S., Mate, C. M., & Philpott, M. R. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.2270 · Cited by 182
Schwingungsprobleme der Technik
Timoshenko, S. P. (1932) · Springer eBooks · doi:10.1007/978-3-642-51350-3 · Cited by 58
Insulating Materials for Semiconductor Surfaces
McMillan, R. E., & Misra, R. P. (1970) · IEEE Transactions on Electrical Insulation · doi:10.1109/tei.1970.299088 · Cited by 14
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 4,297
Self-citationCalculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Self-citationSader, J. E. (1998) · Journal of Applied Physics · doi:10.1063/1.368002 · Cited by 1,410
Scratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy
Carpick, R. W., & Salmeron, M. (1997) · Chemical Reviews · doi:10.1021/cr960068q · Cited by 1,126
Micromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
Self-citation
Metadata
- Authors
- BUTT, H. ‐., SIEDLE, P., SEIFERT, K., FENDLER, K., SEEGER, T., BAMBERG, E., WEISENHORN, A. L., GOLDIE, K., & ENGEL, A.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 169
- Issue
- 1
- Pages
- 75-84
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2165761746
- Cited by
- 233
- References
- 20
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.