Scan speed limit in atomic force microscopy
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
SUMMARY: The scan speed limit of atomic force microscopes has been calculated. It is determined by the spring constant of the cantilever k, its effective mass m, the damping constant D of the cantilever in the surrounding medium and the stiffness of the sample. Techniques to measure k, k/m and D/m are described. In liquids the damping constant and the effective mass of the cantilever increase. A consequence of this is that the transfer function always depends on the scan speed when imaging in liquids. The practical scan speed limit for atomic resolution in vacuum is 0·1 μm/s while in water it increases to about 2 μm/s due to the additional damping of cantilever movements. Sample stiffness or damping of cantilever movements by the sample increase these limits. For soft biological materials imaged in water at a desired resolution of 1 nm the scan speed should not exceed 2 μm/s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
The Feynman Lectures on Physics
Feynman, R. P., Leighton, R. B., Sands, M., & Treiman, S. B. (1964) · Physics Today · doi:10.1063/1.3051743 · Cited by 2,939
Atomic-scale friction of a tungsten tip on a graphite surface
Mate, C. M., McClelland, G. M., Erlandsson, R., & Chiang, S. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.1942 · Cited by 1,763
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
Drake, B., Prater, C. B., Weisenhorn, A. L., Gould, S. A. C., Albrecht, T. R., Quate, C. F., Cannell, D. S., Hansma, H. G., & Hansma, P. K. (1989) · Science · doi:10.1126/science.2928794 · Cited by 1,033
Self-citationMicrofabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747 · cited 3×
“Spring constant and w, were calculated with an elasticity E of 1 5 x 10" N/ m2 and a density p, of 3000 kg/m3 (McMillan & Misra, 1970; Peterson, 1982; Albrecht et al., 1990; Meyer & Amer, 1990; Sarid & Elings. 1991).”
BackgroundMethodInfluentialRugar, D., & Hansma, P. (1990) · Physics Today · doi:10.1063/1.881238 · Cited by 589
Meyer, G., & Amer, N. M. (1990) · Applied Physics Letters · doi:10.1063/1.103950 · Cited by 587
Atomic-Resolution Electrochemistry with the Atomic Force Microscope: Copper Deposition on Gold
Manne, S., Hansma, P. K., Massie, J., Elings, V. B., & Gewirth, A. A. (1991) · Science · doi:10.1126/science.251.4990.183 · Cited by 411
Tip Surface Interactions in STM and AFM
Pethica, J. B., & Oliver, W. C. (1987) · Physica Scripta · doi:10.1088/0031-8949/1987/t19a/010 · Cited by 388
Micromachined silicon sensors for scanning force microscopy
Wolter, O., Bayer, T., & Greschner, J. (1991) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.585195 · Cited by 348
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 4,297
Self-citationCalculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Self-citationSader, J. E. (1998) · Journal of Applied Physics · doi:10.1063/1.368002 · Cited by 1,410
Scratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy
Carpick, R. W., & Salmeron, M. (1997) · Chemical Reviews · doi:10.1021/cr960068q · Cited by 1,126
Micromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
Self-citationHigh-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes
Ando, T., Uchihashi, T., & Fukuma, T. (2008) · Progress in Surface Science · doi:10.1016/j.progsurf.2008.09.001 · Cited by 558
Biomolecular Imaging with the Atomic Force Microscope
Hansma, H. G., & Hoh, J. H. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.000555 · Cited by 539
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Comparison of calibration methods for atomic-force microscopy cantilevers
Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/301 · Cited by 458
Sensing specific molecular interactions with the atomic force microscope
Florin, E.-L., Rief, M., Lehmann, H., Ludwig, M., Dornmair, C., Moy, V. T., & Gaub, H. E. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)99227-c · Cited by 455
Ziegler, C. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2694-y · Cited by 414
Biological applications of atomic force microscopy
Lal, R., & John, S. A. (1994) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1994.266.1.c1 · Cited by 402
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Chon, J. W. M., Mulvaney, P., & Sader, J. E. (2000) · Journal of Applied Physics · doi:10.1063/1.372455 · Cited by 338
Imaging purple membranes in aqueous solutions at sub-nanometer resolution by atomic force microscopy
Müller, D. J., Schabert, F. A., Büldt, G., & Engel, A. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80345-0 · Cited by 324
Self-citationAdhesive and Friction Forces between Chemically Modified Silicon and Silicon Nitride Surfaces
Tsukruk, V. V., & Bliznyuk, V. N. (1998) · Langmuir · doi:10.1021/la970367q · Cited by 318
Studies of vibrating atomic force microscope cantilevers in liquid
Schäffer, T. E., Cleveland, J. P., Ohnesorge, F., Walters, D. A., & Hansma, P. K. (1996) · Journal of Applied Physics · doi:10.1063/1.363308 · Cited by 311
Adsorption of Biological Molecules to a Solid Support for Scanning Probe Microscopy
Müller, D. J., Amrein, M., & Engel, A. (1997) · Journal of Structural Biology · doi:10.1006/jsbi.1997.3875 · Cited by 287
Self-citationSpring constant calibration of atomic force microscope cantilevers of arbitrary shape
Sader, J. E., Sanelli, J. A., Adamson, B. D., Monty, J. P., Wei, X., Crawford, S. A., Friend, J. R., Marusic, I., Mulvaney, P., & Bieske, E. J. (2012) · Review of Scientific Instruments · doi:10.1063/1.4757398 · Cited by 283
Measuring surface forces in aqueous electrolyte solution with the atomic force microscope
Butt, H.-J., Jaschke, M., & Ducker, W. (1995) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(95)01800-t · Cited by 273
Self-citationParallel beam approximation for V-shaped atomic force microscope cantilevers
Sader, J. E. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145292 · Cited by 260
Techniques for measuring surface forces
Claesson, P. M., Ederth, T., Bergeron, V., & Rutland, M. W. (1996) · Advances in Colloid and Interface Science · doi:10.1016/0001-8686(96)00302-8 · Cited by 260
Chemical and Biochemical Analysis Using Scanning Force Microscopy
Takano, H., Kenseth, J. R., Wong, S.-S., O'Brie, J. C., & Porter, M. D. (1999) · Chemical Reviews · doi:10.1021/cr9801317 · Cited by 259
Applications for atomic force microscopy of DNA
Hansma, H. G., Laney, D. E., Bezanilla, M., Sinsheimer, R. L., & Hansma, P. K. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80343-7 · Cited by 248
Atomic force microscopy and spectroscopy of native membrane proteins
Müller, D. J., & Engel, A. (2007) · Nature Protocols · doi:10.1038/nprot.2007.309 · Cited by 234
Self-citationSingle‐Cell Elastography: Probing for Disease with the Atomic Force Microscope
Costa, K. D. (2004) · Disease Markers · doi:10.1155/2004/482680 · Cited by 233
“In particular, variations in the thickness [117] and stoichiometry [118] of commercially available AFM cantilevers can result in spring-constant variability of nearly an order of magnitude between batch-produced wafers [61].”
BackgroundAlcaraz, J., Buscemi, L., Puig-de-Morales, M., Colchero, J., Baró, A., & Navajas, D. (2002) · Langmuir · doi:10.1021/la0110850 · Cited by 188
STM and AFM of bio/organic molecules and structures
Ikai, A. (1996) · Surface Science Reports · doi:10.1016/s0167-5729(97)80003-9 · Cited by 185
Force-induced conformational change of bacteriorhodopsin
Müller, D. J., Büldt, G., & Engel, A. (1995) · Journal of Molecular Biology · doi:10.1006/jmbi.1995.0292 · Cited by 184
Self-citationClifford, C. A., & Seah, M. P. (2005) · Nanotechnology · doi:10.1088/0957-4484/16/9/044 · Cited by 181
Thermomechanical noise of a free v-shaped cantilever for atomic-force microscopy
Stark, R. W., Drobek, T., & Heckl, W. M. (2001) · Ultramicroscopy · doi:10.1016/s0304-3991(00)00077-2 · Cited by 179
Micromechanical mass sensors for biomolecular detection in a physiological environment
Braun, T., Barwich, V., Ghatkesar, M. K., Bredekamp, A. H., Gerber, C., Hegner, M., & Lang, H. P. (2005) · Physical Review E · doi:10.1103/physreve.72.031907 · Cited by 168
Green, C. P., & Sader, J. E. (2002) · Journal of Applied Physics · doi:10.1063/1.1512318 · Cited by 167
Alcohol Induces Interdigitated Domains in Unilamellar Phosphatidylcholine Bilayers
Mou, J., Yang, J., Huang, C., & Shao, Z. (1994) · Biochemistry · doi:10.1021/bi00199a022 · Cited by 163
High resolution imaging of native biological sample surfaces using scanning probe microscopy
Engel, A., Schoenenberger, C.-A., & Müller, D. J. (1997) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(97)80037-1 · Cited by 161
Self-citation
Metadata
- Authors
- BUTT, H. ‐., SIEDLE, P., SEIFERT, K., FENDLER, K., SEEGER, T., BAMBERG, E., WEISENHORN, A. L., GOLDIE, K., & ENGEL, A.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 169
- Issue
- 1
- Pages
- 75-84
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2165761746
- Cited by
- 233
- References
- 20
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.