Graphical representation and multicomponent analysis of single‐frequency fluorescence lifetime imaging microscopy data
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Summary: Graphical representation of fluorescence lifetime imaging microscopy data demonstrates that a mixture of two components with single exponential decays can be resolved by single frequency measurements. We derive a method based on linear fitting that allows the calculation of the fluorescence lifetimes of the two components. We show that introduction of proper error‐weighting results in a non‐linear method that is mathematically identical to a global analysis algorithm that was recently derived. The graphical approach was applied to cellular data obtained from a lifetime‐based phosphorylation assay for the epidermal growth factor receptor and yielded results similar to those obtained by a global analysis algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Fluorescence lifetime imaging microscopy: spatial resolution of biochemical processes in the cell
Bastiaens, P. (1999) · Trends in Cell Biology · doi:10.1016/s0962-8924(98)01410-x · Cited by 716 · cited 1×
“…domain (Lakowicz & Berndt, 1991; Gadella et al ., 1993) has proven to be a valuable tool to resolve spatially the fluorescence lifetimes of one or more probes, for instance to monitor fluorescence resonance energy transfer (FRET) in intact cells (Bastiaens & Squire, 1999; Wouters et al ., 2001).”
Imaging biochemistry inside cells
Wouters, F. S., Verveer, P. J., & Bastiaens, P. I. H. (2001) · Trends in Cell Biology · doi:10.1016/s0962-8924(01)01982-1 · Cited by 395
Self-citationGadella, T. W. J., Jovin, T. M., & Clegg, R. M. (1993) · Biophysical Chemistry · doi:10.1016/0301-4622(93)85012-7 · Cited by 375
Quantitative Imaging of Lateral ErbB1 Receptor Signal Propagation in the Plasma Membrane
Verveer, P. J., Wouters, F. S., Reynolds, A. R., & Bastiaens, P. I. H. (2000) · Science · doi:10.1126/science.290.5496.1567 · Cited by 351 · cited 3×
“These cells were stimulated with epidermal growth factor and then fixed and incubated with a Cy3-labelled antibody against phosphotyrosine (PY72-Cy3, for more information about the assay and applications, see Verveer et al ., 2000b).”
MethodResultSelf-citationLifetime-selective fluorescence imaging using an rf phase-sensitive camera
Lakowicz, J. R., & Berndt, K. W. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142413 · Cited by 257 · cited 1×
“Fluorescence lifetime imaging microscopy (FLIM) in the frequency domain (Lakowicz & Berndt, 1991; Gadella et al ., 1993) has proven to be a valuable tool to resolve spatially the fluorescence lifetimes of one or more probes, for instance to monitor fluorescence resonance energy transfer (FRET) in…”
MethodPepperkok, R., Squire, A., Geley, S., & Bastiaens, P. I. H. (1999) · Current Biology · doi:10.1016/s0960-9822(99)80117-1 · Cited by 249 · cited 2×
“EGFP is known generally to exhibit more than a single exponential in its decay (Pepperkok et al., 1999; Uskova et al., 2000).”
BackgroundGlobal Analysis of Fluorescence Lifetime Imaging Microscopy Data
Verveer, P. J., Squire, A., & Bastiaens, P. I. H. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76759-2 · Cited by 221 · cited 3×
“These cells were stimulated with epidermal growth factor and then fixed and incubated with a Cy3-labelled antibody against phosphotyrosine (PY72-Cy3, for more information about the assay and applications, see Verveer et al ., 2000b).”
MethodResultSelf-citationFluorescence lifetime imaging of receptor tyrosine kinase activity in cells
Wouters, F. S., & Bastiaens, P. I. H. (1999) · Current Biology · doi:10.1016/s0960-9822(99)80484-9 · Cited by 188
Hanley, Q. S., Subramaniam, V., Arndt‐Jovin, D. J., & Jovin, T. M. (2001) · Cytometry · doi:10.1002/1097-0320(20010401)43:4<248::aid-cyto1057>3.0.co;2-y · Cited by 121
Self-citation
Cited by
The Phasor Approach to Fluorescence Lifetime Imaging Analysis
Digman, M. A., Caiolfa, V. R., Zamai, M., & Gratton, E. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120154 · Cited by 1,145
PTRF-Cavin, a Conserved Cytoplasmic Protein Required for Caveola Formation and Function
Hill, M. M., Bastiani, M., Luetterforst, R., Kirkham, M., Kirkham, A., Nixon, S. J., Walser, P., Abankwa, D., Oorschot, V. M. J., Martin, S., et al. (2008) · Cell · doi:10.1016/j.cell.2007.11.042 · Cited by 737
Gehlen, M. H. (2020) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2019.100338 · Cited by 734
Stringari, C., Cinquin, A., Cinquin, O., Digman, M. A., Donovan, P. J., & Gratton, E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1108161108 · Cited by 427
Plasma membrane nanoswitches generate high-fidelity Ras signal transduction
Tian, T., Harding, A., Inder, K., Plowman, S., Parton, R. G., & Hancock, J. F. (2007) · Nature Cell Biology · doi:10.1038/ncb1615 · Cited by 407
Polar Plot Representation for Frequency-Domain Analysis of Fluorescence Lifetimes
Redford, G. I., & Clegg, R. M. (2005) · Journal of Fluorescence · doi:10.1007/s10895-005-2990-8 · Cited by 315
Fluorescence lifetime imaging (FLIM): Basic concepts and some recent developments
Suhling, K., Hirvonen, L. M., Levitt, J. A., Chung, P.-H., Tregidgo, C., Le Marois, A., Rusakov, D. A., Zheng, K., Ameer-Beg, S., Poland, S., et al. (2015) · Medical Photonics · doi:10.1016/j.medpho.2014.12.001 · Cited by 313
Clayton, A. H. A., Walker, F., Orchard, S. G., Henderson, C., Fuchs, D., Rothacker, J., Nice, E. C., & Burgess, A. W. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m504770200 · Cited by 256
Self-citationSun, Y., Day, R. N., & Periasamy, A. (2011) · Nature Protocols · doi:10.1038/nprot.2011.364 · Cited by 240
Rapid Global Fitting of Large Fluorescence Lifetime Imaging Microscopy Datasets
Warren, S. C., Margineanu, A., Alibhai, D., Kelly, D. J., Talbot, C., Alexandrov, Y., Munro, I., Katan, M., Dunsby, C., & French, P. M. W. (2013) · PLoS ONE · doi:10.1371/journal.pone.0070687 · Cited by 234
“using the increasingly popular ‘phasor’ approach [7,8] that provides an immediate indication of the complexity of fluorescence decay profiles and can yield lifetime values for mono- or biexponential decays by linear fitting to distributions of points on the phasor plots – which can be done by inspection for ‘well beha…”
MethodFRET microscopy: from principle to routine technology in cell biology
PIETRASZEWSKA-BOGIEL, A., & GADELLA, T. W. J. (2011) · Journal of Microscopy · doi:10.1111/j.1365-2818.2010.03437.x · Cited by 177
“Although multispecies fitting procedures in FLIM such as global analysis (Verveer & Bastiaens, 2002) or phasor/polar plot analysis (Clayton et al., 2004) can be complicated, they enable the identification of fractions of molecules involved in FRET, which is impossible for methods like filter FRET, spectral FRET, pbFRE…”
MethodFluorescence lifetime imaging microscopy in life sciences
Borst, J. W., & Visser, A. J. W. G. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/10/102002 · Cited by 168
A novel fluorescence lifetime imaging system that optimizes photon efficiency
Colyer, R. A., Lee, C., & Gratton, E. (2008) · Microscopy Research and Technique · doi:10.1002/jemt.20540 · Cited by 166
“The phasor approach to data analysis was previously proposed by us and by others (Clayton et al., 2004; Jameson et al., 1984; Redford and Clegg, 2005).”
BackgroundMethodDiscovery of High-Affinity Noncovalent Allosteric KRAS Inhibitors That Disrupt Effector Binding
McCarthy, M. J., Pagba, C. V., Prakash, P., Naji, A. K., van der Hoeven, D., Liang, H., Gupta, A. K., Zhou, Y., Cho, K.-J., Hancock, J. F., et al. (2019) · ACS Omega · doi:10.1021/acsomega.8b03308 · Cited by 90
Fluorescence Lifetime Imaging Microscopy for Quantitative Biological Imaging
Chen, L.-C., Lloyd, W. R., Chang, C.-W., Sud, D., & Mycek, M.-A. (2013) · Methods in Cell Biology · doi:10.1016/b978-0-12-407761-4.00020-8 · Cited by 55
Metadata
- Authors
- Clayton, A. H. A., Hanley, Q. S., & Verveer, P. J.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2003-12-16
- Volume
- 213
- Issue
- 1
- Pages
- 1-5
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2083087411
- Cited by
- 231
- References
- 12
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.