CoChat

Constraining the variation of fundamental constants at z ∼ 1.3 using 21-cm absorbers: Constraining fundamental constants at z ∼ 1.3

Open access
Rahmani, H., Srianand, R., Gupta, N., Petitjean, P., Noterdaeme, P., Vásquez, D. Albornoz · 2012 · Monthly Notices of the Royal Astronomical Society
Cited by 49

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

We present high-resolution optical spectra obtained with the Ultraviolet and Visual Echelle Spectrograph at the Very Large Telescope and 21-cm absorption spectra obtained with the Giant Metrewave Radio Telescope and the Green Bank Telescope of five quasars along the line of sight of which 21-cm absorption systems at 1.17 < z < 1.56 have been detected previously. We also present milliarcsecond-scale radio images of these quasars obtained with the Very Large Baseline Array. We use the data on four of these systems to constrain the time variation of x ≡ gpα2/μ, where gp is the proton gyromagnetic factor, α is the fine structure constant and μ is the proton-to-electron mass ratio. We carefully evaluate the systematic uncertainties in redshift measurements using cross-correlation analysis and repeated Voigt profile fitting. In both cases, we also confirm our results by analysing optical spectra obtained with the Keck telescope. We find the weighted and the simple means of Δx/x to be, respectively, −(0.1 ± 1.3) × 10−6 and (0.0 ± 1.5) × 10−6 at the mean redshift of 〈z〉 = 1.36 corresponding to a look-back time of ∼9 Gyr. This is the most stringent constraint ever obtained on Δx/x. If we only use the two systems towards quasars unresolved at milliarcsecond scales, we get the simple mean of Δx/x = +(0.2 ± 1.6) × 10−6. Assuming the constancy of other constants, we get Δα/α = (0.0 ± 0.8) × 10−6, which is a factor of 2 better than the best constraints obtained so far using the many-multiplet method. On the other hand, assuming that α and gp have not varied we derive Δμ/μ = (0.0 ± 1.5) × 10−6 which is again the best limit ever obtained on the variation of μ over this redshift range. Using independent constraints on Δα/α at z < 1.8 and Δμ/μ at z ∼ 0.7 available in the literature, we get Δgp/gp ≤ 3.5 × 10−6(1σ).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2966.2012.21503.x

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 49

Metadata

Authors
Rahmani, H., Srianand, R., Gupta, N., Petitjean, P., Noterdaeme, P., & Vásquez, D. A.
Venue
Monthly Notices of the Royal Astronomical Society
Published
2012-08-02
Volume
425
Issue
1
Pages
556-576
ISSN
0035-8711 (ISSN-L)
OpenAlex
W2950410675
Cited by
49
References
11
FWCI
3.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Constraining the variation of fundamental constants at z ∼ 1.3 using 21-cm absorbers: Constraining fundamental constants at z ∼ 1.3. https://app.cochat.ai/papers/10.1111/j.1365-2966.2012.21503.x
The paper
Rahmani, H., Srianand, R., Gupta, N., Petitjean, P., Noterdaeme, P., & Vásquez, D. A. (2012). Constraining the variation of fundamental constants at z ∼ 1.3 using 21-cm absorbers: Constraining fundamental constants at z ∼ 1.3. Monthly Notices of the Royal Astronomical Society. https://doi.org/10.1111/j.1365-2966.2012.21503.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.