Evaluation of a portable ambulatory prototype for automated overnight closed-loop insulin delivery in young people with type 1 diabetes: Home prototype for overnight closed-loop therapy
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate an ambulatory, portable prototype, overnight automated closed-loop (CL) system and to explore optimal time of CL initiation. METHODS: We performed a randomized crossover study and compared automated overnight glucose control started at the time of an evening-meal or at bedtime. Eight young people with type 1 diabetes (T1D) on insulin pump therapy [M = 4; age = 14.3 (1.7) yr; HbA1c = 8.2 (1.3)%; mean (SD)] were studied on two occasions at clinical research facility. A standardized self-selected evening meal [70 (11)g CHO] and snack [22 (4)g CHO] accompanied by prandial insulin boluses were given at 18:00 and 21:00 hours, respectively. In random order, automated CL was started at 18:00 or 21:00 hours and ran until 8:00 hours the next day. Basal insulin delivery was automatically adjusted by a model predictive control algorithm based on real-time continuous glucose monitor readings. RESULTS: Overnight plasma glucose levels (between 21:00 and 08:00 hours) were within the target range (71-145 mg/dL) for 82 (59, 98)% of time when CL started at 18:00 hours and 64 (48, 70)% when CL started at 21:00 hours [median (IQR), p = 0.036]. Time spent above 180 mg/dL [8 (0, 17) vs. 13 (3, 26)%, p = 0.310] or below 70 mg/dL [0 (0,7) vs. 0 (0, 8)%, p = 1.000] did not differ between the two occasions. Mean overnight glucose [121 (14) vs. 137 (13) mg/dL, p = 0.731) was also similar. Overnight insulin infusion rates were comparable [0.8 (0.5, 1.3) vs. 0.8 (0.6, 1.4) U/h, p = 0.263]. No interruptions to CL delivery were observed. CONCLUSION: Automated CL delivery can be applied reliably and safely to control glucose levels overnight in young people with T1D. Tighter glucose levels may be achieved with an earlier time of CL initiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Self-citationHovorka, R., Kumareswaran, K., Harris, J., Allen, J. M., Elleri, D., Xing, D., Kollman, C., Nodale, M., Murphy, H. R., Dunger, D. B., et al. (2011) · BMJ · doi:10.1136/bmj.d1855 · Cited by 244 · cited 2×
“Participants consumed a self-selected evening meal of 70 (11) g carbohydrates at 18:00 hours and a bedtime snack of 22 (4) g carbohydrates at 21:00 hours.”
MethodSelf-citationFrequency and reasons for outcome reporting bias in clinical trials: interviews with trialists
Smyth, R. M. D., Kirkham, J. J., Jacoby, A., Altman, D. G., Gamble, C., & Williamson, P. R. (2011) · BMJ · doi:10.1136/bmj.c7153 · Cited by 220
Kovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200
Cited by
Closed-Loop Artificial Pancreas Systems: Engineering the Algorithms
Doyle, F. J., Huyett, L. M., Lee, J. B., Zisser, H. C., & Dassau, E. (2014) · Diabetes Care · doi:10.2337/dc13-2108 · Cited by 394
A review of personalized blood glucose prediction strategies for T1DM patients
Oviedo, S., Vehí, J., Calm, R., & Armengol, J. (2017) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2833 · Cited by 279
Hovorka, R., Elleri, D., Thabit, H., Allen, J. M., Leelarathna, L., El-Khairi, R., Kumareswaran, K., Caldwell, K., Calhoun, P., Kollman, C., et al. (2014) · Diabetes Care · doi:10.2337/dc13-2644 · Cited by 214
“Closed-Loop System The Florence closed-loop system (24) comprises a model predictive control algorithm residing on a small laptop, which is linked by cable to the sensor receiver and controls the study pump via wireless communication.”
BackgroundSelf-citationThe artificial pancreas: current status and future prospects in the management of diabetes
Peyser, T., Dassau, E., Breton, M., & Skyler, J. S. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12431 · Cited by 169
Harvey, R. A., Dassau, E., Zisser, H., Seborg, D. E., & Doyle, F. J. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814523881 · Cited by 68
“5 (9-22) Hypoglycemia treatments, g CHO 56 (16-112) 24 (0-112) 0 (0-80)”
Metadata
- Authors
- Elleri, D., Allen, J. M., Biagioni, M., Kumareswaran, K., Leelarathna, L., Caldwell, K., Nodale, M., Wilinska, M. E., Acerini, C. L., Dunger, D. B., & Hovorka, R.
- Venue
- Pediatric Diabetes
- Publisher
- Hindawi Limited
- Published
- 2012-07-23
- Volume
- 13
- Issue
- 6
- Pages
- 449-453
- ISSN
- 1399-543X (ISSN-L)
- OpenAlex
- W1546278275
- Cited by
- 53
- References
- 4
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.