CoChat

Evaluation of a portable ambulatory prototype for automated overnight closed-loop insulin delivery in young people with type 1 diabetes: Home prototype for overnight closed-loop therapy

Open access
Elleri, Daniela, Allen, Janet M, Biagioni, Martina, Kumareswaran, Kavita, Leelarathna, Lalantha, Caldwell, Karen, Nodale, Marianna, Wilinska, Malgorzata E, Acerini, Carlo L, Dunger, David B, Hovorka, Roman · 2012 · Pediatric Diabetes
Cited by 53

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To evaluate an ambulatory, portable prototype, overnight automated closed-loop (CL) system and to explore optimal time of CL initiation. METHODS: We performed a randomized crossover study and compared automated overnight glucose control started at the time of an evening-meal or at bedtime. Eight young people with type 1 diabetes (T1D) on insulin pump therapy [M = 4; age = 14.3 (1.7) yr; HbA1c = 8.2 (1.3)%; mean (SD)] were studied on two occasions at clinical research facility. A standardized self-selected evening meal [70 (11)g CHO] and snack [22 (4)g CHO] accompanied by prandial insulin boluses were given at 18:00 and 21:00 hours, respectively. In random order, automated CL was started at 18:00 or 21:00 hours and ran until 8:00 hours the next day. Basal insulin delivery was automatically adjusted by a model predictive control algorithm based on real-time continuous glucose monitor readings. RESULTS: Overnight plasma glucose levels (between 21:00 and 08:00 hours) were within the target range (71-145 mg/dL) for 82 (59, 98)% of time when CL started at 18:00 hours and 64 (48, 70)% when CL started at 21:00 hours [median (IQR), p = 0.036]. Time spent above 180 mg/dL [8 (0, 17) vs. 13 (3, 26)%, p = 0.310] or below 70 mg/dL [0 (0,7) vs. 0 (0, 8)%, p = 1.000] did not differ between the two occasions. Mean overnight glucose [121 (14) vs. 137 (13) mg/dL, p = 0.731) was also similar. Overnight insulin infusion rates were comparable [0.8 (0.5, 1.3) vs. 0.8 (0.6, 1.4) U/h, p = 0.263]. No interruptions to CL delivery were observed. CONCLUSION: Automated CL delivery can be applied reliably and safely to control glucose levels overnight in young people with T1D. Tighter glucose levels may be achieved with an earlier time of CL initiation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1399-5448.2012.00903.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Elleri, D., Allen, J. M., Biagioni, M., Kumareswaran, K., Leelarathna, L., Caldwell, K., Nodale, M., Wilinska, M. E., Acerini, C. L., Dunger, D. B., & Hovorka, R.
Venue
Pediatric Diabetes
Published
2012-07-23
Volume
13
Issue
6
Pages
449-453
ISSN
1399-543X (ISSN-L)
OpenAlex
W1546278275
Cited by
53
References
4
FWCI
7.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.