CoChat

Non‐invasive blood pressure monitoring during head‐up tilt using the Penaz principle

Friedman, D. B., Jensen, F. B., Matzen, S., Secher, N. H. · 1990 · Acta Anaesthesiologica Scandinavica
Cited by 81

The DOI matches its Crossref record.

Abstract

Continuous blood pressure measurement by a non‐invasive means is of clinical utility in many situations where changes in cardiovascular hemodynamics and blood volume distribution are likely to occur. We have compared blood pressure measurements using the Penaz principle (Finapres, Ohmeda) to an intra‐arterial catheter system during head‐up tilt (reverse Trendelenburg' s position) which models central hypovolemia. Twelve healthy volunteers were raised to a 60Â˚ head‐up tilt position for 60 min or until presyncope occurred. Seven subjects developed presyncopal symptoms at a mean time of 38 + 6 min with blood pressure measured by the Penaz principle falling from 140 ± 8/72 ± 4 to 82 ± 10/54 ± 6 mmHg (18.7 ± 1.1/9.6 ± 0.5 to 10.9 ± 1.3/ 7.2±0.8 kPa) (P<0.01), at which point they were returned to a horizontal position with an immediate rise in blood pressure. During the maximal drop in blood pressure, heart rate decreased from 82 ± 7 to 45 + 5 (P<0.01). Overall, the non‐invasive system had a correlation coefficient of 0.98 as compared to the intraarterial method and ECG for blood pressure and heart rate in all 12 subjects during rest, tilt, and recovery. We conclude that the Penaz principle apparatus is a useful monitor of symptomatic hypotension during central hypovolemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1399-6576.1990.tb03137.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Metadata

Authors
Friedman, D. B., Jensen, F. B., Matzen, S., & Secher, N. H.
Venue
Acta Anaesthesiologica Scandinavica
Publisher
Wiley
Published
1990-10
Volume
34
Issue
7
Pages
519-522
ISSN
  • 0001-5172 (ISSN-L)
  • 1399-6576
OpenAlex
W2026511161
Cited by
81
References
0
FWCI
5.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non‐invasive blood pressure monitoring during head‐up tilt using the Penaz principle. https://app.cochat.ai/papers/10.1111/j.1399-6576.1990.tb03137.x
The paper
Friedman, D. B., Jensen, F. B., Matzen, S., & Secher, N. H. (1990). Non‐invasive blood pressure monitoring during head‐up tilt using the Penaz principle. Acta Anaesthesiologica Scandinavica. https://doi.org/10.1111/j.1399-6576.1990.tb03137.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.