Non‐invasive blood pressure monitoring during head‐up tilt using the Penaz principle
The DOI matches its Crossref record.
Abstract
Continuous blood pressure measurement by a non‐invasive means is of clinical utility in many situations where changes in cardiovascular hemodynamics and blood volume distribution are likely to occur. We have compared blood pressure measurements using the Penaz principle (Finapres, Ohmeda) to an intra‐arterial catheter system during head‐up tilt (reverse Trendelenburg' s position) which models central hypovolemia. Twelve healthy volunteers were raised to a 60Â˚ head‐up tilt position for 60 min or until presyncope occurred. Seven subjects developed presyncopal symptoms at a mean time of 38 + 6 min with blood pressure measured by the Penaz principle falling from 140 ± 8/72 ± 4 to 82 ± 10/54 ± 6 mmHg (18.7 ± 1.1/9.6 ± 0.5 to 10.9 ± 1.3/ 7.2±0.8 kPa) (P<0.01), at which point they were returned to a horizontal position with an immediate rise in blood pressure. During the maximal drop in blood pressure, heart rate decreased from 82 ± 7 to 45 + 5 (P<0.01). Overall, the non‐invasive system had a correlation coefficient of 0.98 as compared to the intraarterial method and ECG for blood pressure and heart rate in all 12 subjects during rest, tilt, and recovery. We conclude that the Penaz principle apparatus is a useful monitor of symptomatic hypotension during central hypovolemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Piepoli, M., Clark, A. L., Volterrani, M., Adamopoulos, S., Sleight, P., & Coats, A. J. S. (1996) · Circulation · doi:10.1161/01.cir.93.5.940 · Cited by 545
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
HARMS, M. P. M., WESSELING, K. H., POTT, F., JENSTRUP, M., VAN GOUDOEVER, J., SECHER, N. H., & VAN LIESHOUT, J. J. (1999) · Clinical Science · doi:10.1042/cs0970291 · Cited by 345
Self-citationImpaired Cerebral Autoregulation in Patients With Malignant Hypertension
Immink, R. V., van den Born, B.-J. H., van Montfrans, G. A., Koopmans, R. P., Karemaker, J. M., & van Lieshout, J. J. (2004) · Circulation · doi:10.1161/01.cir.0000144472.08647.40 · Cited by 243
Laurent, S., Girerd, X., Mourad, J. J., Lacolley, P., Beck, L., Boutouyrie, P., Mignot, J. P., & Safar, M. (1994) · Arteriosclerosis and Thrombosis: A Journal of Vascular Biology · doi:10.1161/01.atv.14.7.1223 · Cited by 237
Nexfin Noninvasive Continuous Blood Pressure Validated Against Riva-Rocci/Korotkoff
Eeftinck Schattenkerk, D. W., van Lieshout, J. J., van den Meiracker, A. H., Wesseling, K. R., Blanc, S., Wieling, W., van Montfrans, G. A., Settels, J. J., Wesseling, K. H., & Westerhof, B. E. (2009) · American Journal of Hypertension · doi:10.1038/ajh.2008.368 · Cited by 222
Isometric arm counter-pressure maneuvers to abort impending vasovagal syncope
Brignole, M., Croci, F., Menozzi, C., Solano, A., Donateo, P., Oddone, D., Puggioni, E., & Lolli, G. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02683-9 · Cited by 208
Morillo, C. A., Leitch, J. W., Yee, R., & Klein, G. J. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90767-u · Cited by 197
Leitch, J. W., Klein, G. J., Yee, R., Leather, R. A., & Kim, Y. H. (1992) · Circulation · doi:10.1161/01.cir.85.3.1064 · Cited by 171
HARKEL, A. D. J. T., VAN LIESHOUT, J. J., & WIELING, W. (1992) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1992.tb00563.x · Cited by 151
van Lieshout, J. J., ten Harkel, A. D. J., & Wieling, W. (2000) · Clinical Autonomic Research · doi:10.1007/bf02291388 · Cited by 144
“The Finapres measurement is based on the volume clamp technique of Pefi~z and the Physiocal criteria of Wesseling [17J and accurately reflects systolic, mean, and diastolic BP changes during complex maneuvers such as standing up [18] as well as during arterial hypotension [ 19-21 ].”
MethodTen Harkel, A. D. J., Van Lieshout, J. J., & Wieling, W. (1994) · Clinical Science · doi:10.1042/cs0870553 · Cited by 128
Role of autonomic reflexes in syncope associated with paroxysmal atrial fibrillation
Brignole, M., Gianfranchi, L., Menozzi, C., Raviele, A., Oddone, D., Lolli, G., & Bottoni, N. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90426-2 · Cited by 114
Brignole, M., Gaggioli, G., Menozzi, C., Gianfranchi, L., Bartoletti, A., Bottoni, N., Lolli, G., Oddone, D., Rosso, A. D., & Pellinghelli, G. (1997) · Circulation · doi:10.1161/01.cir.96.11.3921 · Cited by 98
Metadata
- Authors
- Friedman, D. B., Jensen, F. B., Matzen, S., & Secher, N. H.
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 1990-10
- Volume
- 34
- Issue
- 7
- Pages
- 519-522
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W2026511161
- Cited by
- 81
- References
- 0
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.