CoChat

Respiration can be monitored by photoplethysmography with high sensitivity and specificity regardless of anaesthesia and ventilatory mode

Nilsson, L., Johansson, A., Kalman, S. · 2005 · Acta Anaesthesiologica Scandinavica
Cited by 78

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Photoplethysmography (PPG) is a non‐invasive optical technique used, for instance, in pulse oximetry. Beside the pulse synchronous component, PPG has a respiratory synchronous variation (PPGr). Efforts have been made to utilize this component for indirect monitoring of respiratory rate and volume. Assessment of the clinical usefulness as well as of the physiological background of PPGr is required. We evaluated if anaesthesia and positive‐pressure ventilation would affect PPGr. Methods: We recorded reflection mode PPGr, at the forearm, and the respiratory synchronous changes in central venous pressure (CVP), peripheral venous pressure (PVP) and arterial blood pressure (ABP) in 12 patients. Recordings for each patient were made on three occasions: awake with spontaneous breathing; anaesthetized with spontaneous breathing; and anaesthetized with positive‐pressure ventilation. We analyzed the sensitivity, specificity, coherence and time relationship between the signals. Results: PPGr sensitivity for breath detection was [mean (SD)] >86(21)% and specificity >96(12)%. Respiratory detection in the macrocirculation (CVP, PVP and ABP) showed a sensitivity >83(29)% and specificity >93(12)%. The coherence between signals was high (0.75–0.99). The three measurement situations did not significantly influence sensitivity, specificity or time shifts between the PPGr, PVP, ABP, and the reference CVP signal despite changes in physiological data between measurements. Conclusion: A respiratory synchronous variation in PPG and all invasive pressure signals was detected. The reflection mode PPGr signal seemed to be a constant phenomenon related to respiration regardless of whether or not the subject was awake, anaesthetized or ventilated, which increases its clinical usefulness in respiratory monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1399-6576.2005.00721.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 78

Metadata

Authors
Nilsson, L., Johansson, A., & Kalman, S.
Venue
Acta Anaesthesiologica Scandinavica
Publisher
Wiley
Published
2005-04-21
Volume
49
Issue
8
Pages
1157-1162
ISSN
  • 0001-5172 (ISSN-L)
  • 1399-6576
OpenAlex
W2146832422
Cited by
78
References
2
FWCI
3.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.