CoChat

Photography of the anterior eye segment according to Scheimpflug's principle: options and limitations – a review

Wegener, Alfred, Laser‐Junga, Heike · 2009 · Clinical & Experimental Ophthalmology
Cited by 160

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Scheimpflug photography and densitometric image analysis are very precise techniques for light scattering measurement and biometry in the anterior segment of the eye. They provide reproducible data on the characteristics of the anterior eye segment in clinical and experimental studies and the set of data obtained allows discrimination of light scattering changes because of ageing, disease or toxic effects. The techniques can also be used to determine no‐effect levels or maximally tolerable dosages of physical and chemical noxious factors. Several Scheimpflug cameras have been marketed, but the only cameras commercially available today are the Nidek EAS 1000 and the Oculus Pentacam. This review outlines the development of the technique and its introduction into ophthalmology. Furthermore, the application of the technique in clinical and experimental ophthalmology as well as in ocular toxicology are presented and discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1442-9071.2009.02018.x

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Wegener, A., & Laser‐Junga, H.
Venue
Clinical & Experimental Ophthalmology
Publisher
Wiley
Published
2009-01
Volume
37
Issue
1
Pages
144-154
ISSN
  • 1442-6404 (ISSN-L)
  • 1442-9071
OpenAlex
W2079966964
Cited by
160
References
16
FWCI
8.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.