Patient handover from surgery to intensive care: using Formula 1 pit‐stop and aviation models to improve safety and quality
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Summary: Background: We aimed to improve the quality and safety of handover of patients from surgery to intensive care using the analogy of a Formula 1 pit stop and expertise from aviation. Methods: A prospective intervention study measured the change in performance before and after the implementation of a new handover protocol that was developed through detailed discussions with a Formula 1 racing team and aviation training captains. Fifty (23 before and 27 after) postsurgery patient handovers were observed. Technical errors and information omissions were measured using checklists, and teamwork was scored using a Likert scale. Duration of the handover was also measured. Results: The mean number of technical errors was reduced from 5.42 (95% CI ±1.24) to 3.15 (95% CI ±0.71), the mean number of information handover omissions was reduced from 2.09 (95% CI ±1.14) to 1.07 (95% CI ±0.55), and duration of handover was reduced from 10.8 min (95% CI ±1.6) to 9.4 min (95% CI ±1.29). Nine out of twenty‐three (39%) precondition patients had more than one error in both technical and information handover prior to the new protocol, compared with three out of twnety‐seven (11.5%) with the new handover. Regression analysis showed that the number of technical errors were significantly reduced with the new handover (t = −3.63, P < 0.001), and an interaction suggested that teamwork (t = 3.04, P = 0.004) had a different effect with the new handover protocol. Conclusions: The introduction of the new handover protocol lead to improvements in all aspects of the handover. Expertise from other industries can be extrapolated to improve patient safety, and in particular, areas of medicine involving the handover of patients or information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus-based method for risk adjustment for surgery for congenital heart disease
Jenkins, K. J., Gauvreau, K., Newburger, J. W., Spray, T. L., Moller, J. H., & Iezzoni, L. I. (2002) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2002.119064 · Cited by 1,368
Morey, J. C., Simon, R., Jay, G. D., Wears, R. L., Salisbury, M., Dukes, K. A., & Berns, S. D. (2002) · Health Services Research · doi:10.1111/1475-6773.01104 · Cited by 1,001
(2000) · CRC Press eBooks · doi:10.1201/b12791 · Cited by 793
Human factors and cardiac surgery: A multicenter study
de Leval, M. R., Carthey, J., Wright, D. J., Farewell, V. T., & Reason, J. T. (2000) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(00)70006-7 · Cited by 507
Self-citationThe role of non-technical skills in anaesthesia: a review of current literature
Fletcher, G. C. L., McGeorge, P., Flin, R. H., Glavin, R. J., & Maran, N. J. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.3.418 · Cited by 423
Woolf, S. H. (2004) · The Annals of Family Medicine · doi:10.1370/afm.126 · Cited by 225
Kluger, M. T., & Bullock, M. F. M. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02865.x · Cited by 181
Identification of systems failures in successful paediatric cardiac surgery
Catchpole, K. R., Giddings, A. E. B., de Leval, M. R., Peek, G. J., Godden, P. J., Utley, M., Gallivan, S., Hirst, G., & Dale, T. (2006) · Ergonomics · doi:10.1080/00140130600568865 · Cited by 181
Self-citationPilot study to show the loss of important data in nursing handover
Pothier, D., Monteiro, P., Mooktiar, M., & Shaw, A. (2005) · British Journal of Nursing · doi:10.12968/bjon.2005.14.20.20053 · Cited by 170
The role of structured observational research in health care
Carthey, J. (2003) · BMJ Quality & Safety · doi:10.1136/qhc.12.suppl_2.ii13 · Cited by 107
How Unexpected Events Produce an Escalation of Cognitive and Coordinative Demands
Woods, D. D., & Patterson, E. S. (2000) · Stress, Workload, and Fatigue · doi:10.1201/b12791-2.3 · Cited by 104
Challenging the handover ritual
O'Connell, B. O., & Penney, W. (2001) · Collegian Journal of the Royal College of Nursing Australia · doi:10.1016/s1322-7696(08)60017-7 · Cited by 91
Hofer, T. P., & Hayward, R. A. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-5_part_1-200209030-00008 · Cited by 91
Handover of responsibility for the anaesthetised patient – opinion and practice
Horn, J., Bell, M. D. D., & Moss, E. (2004) · Anaesthesia · doi:10.1111/j.1365-2044.2004.03760.x · Cited by 66
Identifying and Reducing Errors in the Operating Theatre
Catchpole, K., & de Leval, P. M. (2004) · Journal of Blindness Innovation and Research · doi:10.1201/9780203494172.ch63 · Cited by 20
Self-citation
Cited by
Best care at lower cost: the path to continuously learning health care in America
(2014) · Choice Reviews Online · doi:10.5860/choice.51-3277 · Cited by 1,363
Safety culture in healthcare: a review of concepts, dimensions, measures and progress
Halligan, M., & Zecevic, A. (2011) · BMJ Quality & Safety · doi:10.1136/bmjqs.2010.040964 · Cited by 403
The published literature on handoffs in hospitals: deficiencies identified in an extensive review
Cohen, M. D., & Hilligoss, P. B. (2010) · BMJ Quality & Safety · doi:10.1136/qshc.2009.033480 · Cited by 392
Wahr, J. A., Prager, R. L., Abernathy, J. H., Martinez, E. A., Salas, E., Seifert, P. C., Groom, R. C., Spiess, B. D., Searles, B. E., Sundt, T. M., et al. (2013) · Circulation · doi:10.1161/cir.0b013e3182a38efa · Cited by 334
Developing a team performance framework for the intensive care unit*
Reader, T. W., Flin, R., Mearns, K., & Cuthbertson, B. H. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819f0451 · Cited by 295
Metadata
- Authors
- CATCHPOLE, K. R., DE LEVAL, M. R., MCEWAN, A., PIGOTT, N., ELLIOTT, M. J., MCQUILLAN, A., MACDONALD, C., & GOLDMAN, A. J.
- Venue
- Pediatric Anesthesia
- Publisher
- Wiley
- Published
- 2007-04-17
- Volume
- 17
- Issue
- 5
- Pages
- 470-478
- ISSN
- 1155-5645 (ISSN-L)
- 1460-9592
- OpenAlex
- W2116240446
- Cited by
- 516
- References
- 15
- FWCI
- 24.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.