CoChat

Basal Rate Subcutaneous Insulin Infusion: Absorption Kinetics and Relation to Local Blood Flow

Hildebrandt, P., Birch, K. · 1988 · Diabetic Medicine
Cited by 20

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Twenty diabetic patients received a constant subcutaneous infusion of 125 l‐labelled short‐acting insulin (1.12 U/h) into the anterior abdominal wall. Measurement of the size of the insulin depot at the infusion site was performed by measuring the radioactivity and by using a calibration bolus to transform count rate to units of insulin in the depot. By the 133 Xenon technique, local subcutaneous blood flow rate was measured on the contrala‐teral side of the anterior abdominal wall. From the start of the infusion the SC depot built up slowly, but did not reach steady‐state by 6 h. After 24 h of infusion, the size of the depot ranged between 2.7 and 10.9 U (5.2 ± 0.5 U, mean ± SE). The size of this steady‐state depot was inversely correlated with SC blood flow. After stopping the infusion, insulin disappeared according to first order kinetics without any lag period. The insulin disappearance rate from the depot was positively correlated with the blood flow in a curvilinear fashion. The results suggest that the relationship between blood flow and the size of the insulin depot is best explained by a predominantly blood flow limited removal of insulin at low rates of blood flow, with increasing limitation by diffusion at higher rates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1464-5491.1988.tb01023.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 35

  1. Binder C., 1969, Absorption of injected insulin, Acta Pharmacol Toxicol, 27, 1, 10.1111/j.1600-0773.1969.tb03069.x · DOI · Paper page
  2. 10.1007/BF01235885 · DOI
  3. 10.1111/j.1651-2227.1980.tb15323.x · DOI · Paper page
  4. 10.1055/s-2007-1018694 · DOI · Paper page
  5. 10.1080/00365518509155280 · DOI · Paper page
  6. 10.2337/diab.29.3.206 · DOI · Paper page
  7. Schiffrin A., 1982, Comparison between continuous subcutaneous insulin infusion and multiple subcutaneous injections: one year prospective study, Diabetes, 31, 255, 10.2337/diab.31.3.255 · DOI · Paper page
  8. 10.2337/diabetes.32.4.331 · DOI
  9. 10.1007/BF00252409 · DOI
  10. 10.2337/diacare.8.3.287 · doi:10.2337/diacare.8.3.287
  11. 10.1007/BF00251817 · DOI
  12. 10.1016/0026-0495(81)90177-3 · DOI
  13. 10.1007/BF00253183 · DOI
  14. Sejrsen P., 1971, Measurement of cutaneous blood flow by freely diffusible radioactive isotopes., Dan Med Bull, 1
  15. 10.3109/00365517209081052 · doi:10.3109/00365517209081052
  16. 10.1007/BF01222209 · DOI
  17. 10.1007/BF00251287 · DOI
  18. Paaske W., 1980, Recruitment of skeletal muscle capillaries using the Permeability‐Surface Area Product (PS) as an index of perfused microvascular exchange area, Acta Physiol Scand, 108, 45A
  19. Bülow J., 1976, Variation in human subcutaneous adipose tissue blood flow (ATBF), Acta Physiol Scand, 96, 30A
  20. Lassen NA, 1979, Tracer Kinetic Methods in Medical Physiology
  21. 10.2337/diacare.6.5.459 · DOI · Paper page
  22. 10.2337/diab.32.5.466 · DOI
  23. Chisholm DJ, 1984, Low subcutaneous degradation and slow absorption of insulin in insulin‐dependent diabetic patients during continuous subcutaneous insulin infusion at basal rate, Diabetologia, 27, 238, 10.1007/BF00273813 · DOI
  24. Hildebrandt P., 1985, Orthostatic changes in subcutaneous blood flow and insulin absorption, Diabetes Research, 2, 187
  25. 10.1111/j.1475-097X.1985.tb00757.x · DOI
  26. 10.1111/j.1475-097X.1982.tb00037.x · DOI
  27. 10.3109/00365517309084321 · doi:10.3109/00365517309084321
  28. 10.1007/BF00423039 · doi:10.1007/bf00423039
  29. 10.1007/BF00585246 · DOI
  30. 10.1056/NEJM197801122980205 · DOI · Paper page
  31. 10.2337/diacare.5.2.77 · DOI · Paper page
  32. Linde B., 1985, The importance of local blood flow for the massage‐induced enhancement of insulin absorption from the subcutaneous injection site., Diabetes Res Clin Pract, S340
  33. 10.2337/diacare.7.4.338 · DOI
  34. 10.1007/BF00251815 · DOI
  35. 10.1016/S0140-6736(80)92654-9 · DOI

Cited by

See all 20

Metadata

Authors
Hildebrandt, P., & Birch, K.
Venue
Diabetic Medicine
Publisher
Wiley
Published
1988-07-08
Volume
5
Issue
5
Pages
434-440
ISSN
  • 0742-3071
  • 1464-5491
Cited by
20
References
3
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Basal Rate Subcutaneous Insulin Infusion: Absorption Kinetics and Relation to Local Blood Flow. https://app.cochat.ai/papers/10.1111/j.1464-5491.1988.tb01023.x
The paper
Hildebrandt, P., & Birch, K. (1988). Basal Rate Subcutaneous Insulin Infusion: Absorption Kinetics and Relation to Local Blood Flow. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.1988.tb01023.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.