In vivo measurements of the triceps surae complex architecture in man: implications for muscle function
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The objectives of this study were to (1) quantify experimentally in vivo changes in pennation angle, fibre length and muscle thickness in the triceps surae complex in man in response to changes in ankle position and isometric plantarflexion moment and (2) compare changes in the above muscle architectural characteristics occurring in the transition from rest to a given isometric plantarflexion intensity with the estimations of a planimetric muscle model assuming constant thickness and straight muscle fibres. The gastrocnemius medialis (GM), gastrocnemius lateralis (GL) and soleus (SOL) muscles of six males were scanned with ultrasonography at different sites along and across the muscle belly at rest and during maximum voluntary contraction (MVC) trials at ankle angles of −15 deg (dorsiflexed direction), 0 deg (neutral position), +15 deg (plantarflexed direction) and +30 deg. Additional images were taken at 80, 60, 40 and 20 % of MVC at an ankle angle of 0 deg. In all three muscles and all scanned sites, as ankle angle increased from −15 to +30 deg, pennation increased (by 6–12 deg, 39–67 %, P < 0.01 at rest and 9–16 deg, 29–43 %, P < 0.01 during MVC) and fibre length decreased (by 15–28 mm, 32–34 %, P < 0.01 at rest and 8–10 mm, 27–30 %, P < 0.05 during MVC). Thickness in GL and SOL increased during MVC compared with rest (by 5–7 mm, 36–47 %, P < 0.01 in GL and 6–7 mm, 38–47 %, P < 0.01 in SOL) while thickness of GM did not differ (P > 0.05) between rest and MVC. At any given ankle angle the model underestimated changes in GL and SOL occurring in the transition from rest to MVC in pennation angle (by 9–12 deg, 24–38 %, P < 0.01 in GL and 9–14 deg, 25–28 %, P < 0.01 in SOL) and fibre length (by 6–15 mm, 22–39 %, P < 0.01 in GL and 6–8 mm, 23–24 %, P < 0.01 in SOL). The findings of the study indicate that the mechanical output of muscle as estimated by the model used may be unrealistic due to errors in estimating the changes in muscle architecture during contraction compared with rest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 3,673
Muscle Architecture of the Human Lower Limb
Wickiewicz, T. L., Roy, R. R., Powell, P. L., & Edgerton, V. R. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198310000-00042 · Cited by 928
Multiple Muscle Systems: Biomechanics and Movement Organization
Winters, J. M., & Woo, S. L. (2011) · Medical Entomology and Zoology · Cited by 788
Narici, M. V., Binzoni, T., Hiltbrand, E., Fasel, J., Terrier, F., & Cerretelli, P. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021685 · Cited by 555
Muscle fiber architecture in the human lower limb
Friederich, J. A., & Brand, R. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90373-b · Cited by 548
Muscle-fiber pennation angles are greater in hypertrophied than in normal muscles
Kawakami, Y., Abe, T., & Fukunaga, T. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.6.2740 · Cited by 518
Physiological cross‐sectional area of human leg muscles based on magnetic resonance imaging
Fukunaga, T., Roy, R. R., Shellock, F. G., Hodgson, J. A., Day, M. K., Lee, P. L., Kwong‐Fu, H., & Edgerton, V. R. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100623 · Cited by 514
FIBER ARCHITECTURE AND MUSCLE FUNCTION
Gans, C. (1982) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-198201000-00006 · Cited by 491
The functional significance of muscle architecture--a theoretical analysis.
Gans, C., & Bock, W. (1965) · PubMed · Cited by 464
Intramuscular fluid pressure during isometric contraction of human skeletal muscle
Sejersted, O. M., Hargens, A. R., Kardel, K. R., Blom, P., Jensen, O., & Hermansen, L. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.2.287 · Cited by 355
Training-induced changes in muscle architecture and specific tension
Kawakami, Y., Abe, T., Kuno, S.-Y., & Fukunaga, T. (1995) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00964112 · Cited by 334
Concepts and Models of Functional Architecture in Skeletal Muscle
OTTEN, E. (1988) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-198800160-00006 · Cited by 282
Narici, M. V., Landoni, L., & Minetti, A. E. (1992) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00243511 · Cited by 281
Muscle architecture and function in humans
Fukunaga, T., Kawakami, Y., Kuno, S., Funato, K., & Fukashiro, S. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00171-6 · Cited by 246
Woittiez, R. D., Huijing, P. A., Boom, H. B. K., & Rozendal, R. H. (1984) · Journal of Morphology · doi:10.1002/jmor.1051820107 · Cited by 234
Measurement of fibre pennation using ultrasound in the human quadriceps in vivo
Rutherford, O. M., & Jones, D. A. (1992) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00243510 · Cited by 224
Active length‐tension relation and the effect of muscle pinnation on fiber lengthening
Muhl, Z. F. (1982) · Journal of Morphology · doi:10.1002/jmor.1051730305 · Cited by 213
Herbert, R. D., & Gandevia, S. C. (1995) · The Journal of Physiology · doi:10.1113/jphysiol.1995.sp020683 · Cited by 180
Specific tension of elbow flexor and extensor muscles based on magnetic resonance imaging
Kawakami, Y., Nakazawa, K., Fujimoto, T., Nozaki, D., Miyashita, M., & Fukunaga, T. (1994) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00244027 · Cited by 159
Modelling mechanically stable muscle architectures
Van Leeuwen, J. L., & Spoor, C. W. (1992) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1992.0061 · Cited by 124
Volume change and pressure development in muscle during contraction
Baskin, R., & Paolini, P. J. (1967) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1967.213.4.1025 · Cited by 121
Do muscle fibre size and fibre angulation correlate in pennated human muscles?
Henriksson-Larsén, K., Wretling, M.-L., Lorentzon, R., & �berg, L. (1992) · European Journal of Applied Physiology · doi:10.1007/bf00376443 · Cited by 91
Changes in geometry of activily shortening unipennate rat gastrocnemius muscle
Zuurbier, C. J., & Huijing, P. A. (1993) · Journal of Morphology · doi:10.1002/jmor.1052180206 · Cited by 91
The Effect of Architecture On Skeletal Muscle Performance: a Simple Planimetric Model
Woittiez, R. D., & Huijing, P. A. (1983) · Netherlands Journal of Zoology · doi:10.1163/002829684x00029 · Cited by 67
Cited by
Measurement of muscle contraction with ultrasound imaging
Hodges, P. W., Pengel, L. H. M., Herbert, R. D., & Gandevia, S. C. (2003) · Muscle & Nerve · doi:10.1002/mus.10375 · Cited by 816
Aagaard, P., Andersen, J. L., Dyhre‐Poulsen, P., Leffers, A., Wagner, A., Magnusson, S. P., Halkjær‐Kristensen, J., & Simonsen, E. B. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.t01-1-00613.x · Cited by 733
Are Current Measurements of Lower Extremity Muscle Architecture Accurate?
Ward, S. R., Eng, C. M., Smallwood, L. H., & Lieber, R. L. (2009) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-008-0594-8 · Cited by 693
In vivo behaviour of human muscle tendon during walking
Fukunaga, T., Kubo, K., Kawakami, Y., Fukashiro, S., Kanehisa, H., & Maganaris, C. N. (2001) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.2000.1361 · Cited by 589
Self-citationEffect of aging on human muscle architecture
Narici, M. V., Maganaris, C. N., Reeves, N. D., & Capodaglio, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00433.2003 · Cited by 543
Self-citation
Metadata
- Authors
- Maganaris, C. N., Baltzopoulos, V., & Sargeant, A. J.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1998-10
- Volume
- 512
- Issue
- 2
- Pages
- 603-614
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2058560059
- Cited by
- 402
- References
- 24
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.