CoChat

Firing properties of single vasoconstrictor neurones in human subjects with high levels of muscle sympathetic activity

Open access
Macefield, Vaughan G., Wallin, B. Gunnar · 1999 · The Journal of Physiology
Cited by 114

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

1. Single-unit recordings were made from 19 postganglionic muscle vasoconstrictor axons via tungsten microelectrodes in the peroneal nerve in seven healthy subjects with many multi-unit sympathetic discharges at rest ('high group', 75 +/- 5 multi-unit bursts per 100 heart beats, mean +/- s.e.m.). The results were compared with previous data from 14 units in subjects with 21 +/- 2 multi-unit bursts per 100 heart beats ('low group'). 2. In the 'high group' the units fired spontaneously in 35 +/- 4 % of all cardiac intervals. One unit only ever fired once per cardiac interval, 14 units (74 %) generated maximally two to three spikes, and four units (21 %) up to four to five spikes. Of those cardiac intervals in which a unit fired, a single spike occurred in 78 %, two spikes in 18 %, three spikes in 4 % and four spikes in less than 1 % of cardiac intervals. Measured as the inverse of all interspike intervals, the mean rate was 0.33 +/- 0.04 Hz and the mean intraburst frequency 22.2 +/- 1.6 Hz. Most results were similar to those in the 'low group', but in the 'low group' heart rate was higher (64.5 vs. 50.4 beats min-1) and mean firing frequency was higher (0.49 +/- 0.06 Hz). 3. During increases of multi-unit burst activity evoked by sustained inspiratory-capacity apnoea the firing probability of nine units in the 'high group' increased from 33 +/- 6 to 56 +/- 3 % of the cardiac intervals. Simultaneously, the incidence of single spikes decreased and the incidence of multiple spikes per cardiac interval increased, resulting in an increase of mean firing frequency from 0. 23 +/- 0.04 Hz at rest to 1.04 +/- 0.14 Hz during the apnoea. 4. We conclude that single muscle vasoconstrictor neurones usually fire only a solitary spike during sympathetic bursts both in subjects with a high and in subjects with a low number of bursts at rest. Presumably, differences in the numbers of bursts are due mainly to differences in firing probability and recruitment of sympathetic fibres. During acute increases of multi-unit activity, both increases in discharge frequency and recruitment of additional neurones contribute to the increased intensity of an individual sympathetic burst.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-7793.1999.293aa.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 114

Metadata

Authors
Macefield, V. G., & Wallin, B. G.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1999-04
Volume
516
Issue
1
Pages
293-301
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2118694904
Cited by
114
References
5
FWCI
2.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Firing properties of single vasoconstrictor neurones in human subjects with high levels of muscle sympathetic activity. https://app.cochat.ai/papers/10.1111/j.1469-7793.1999.293aa.x
The paper
Macefield, V. G., & Wallin, B. G. (1999). Firing properties of single vasoconstrictor neurones in human subjects with high levels of muscle sympathetic activity. The Journal of Physiology. https://doi.org/10.1111/j.1469-7793.1999.293aa.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.