Pulse Wave Velocity and Blood Pressure Change: Calibration and Applications
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
An adaptation of the technique for measuring pulse wave velocity is described in which the interval between the R wave of the ECG and the radial pressure pulse is monitored. The resulting transit time (TT) is suitable for use as an indirect measure of blood pressure change. The reliability of the measure was assessed in 5 subjects who volunteered for arterial cannulation on 2 occasions. Simultaneous recordings of intra‐arterial pressure and TT were taken during a variety of maneouvres, including mental arithmetic, isometric exercise, and amyl nitrite inhalation. The dependence of changes in TT on arterial pressure was confirmed for all procedures except amyl nitrite inhalation. Linear correlations between TT and mean arterial pressure were high, varying between −.913 and −.98. The regression coefficients were reproducible and similar in all individuals. The reasons for the anomalous amyl nitrite response are discussed, together with the limits of application of the measure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brod, J., Fencl, V., Hejl, Z., & Jirka, J. (1959) · PubMed · Cited by 420
Harris, W. S., Schoenfeld, C. D., & Weissler, A. M. (1967) · Journal of Clinical Investigation · doi:10.1172/jci105661 · Cited by 266
Pulse Wave Velocity as a Measure of Blood Pressure Change
Gribbin, B., Steptoe, A., & Sleight, P. (1976) · Psychophysiology · doi:10.1111/j.1469-8986.1976.tb03344.x · Cited by 225
Self-citationDuration of the Phases of Left Ventricular Systole
WALLACE, A. G., MITCHELL, J. H., SKINNER, N. S., & SARNOFF, S. J. (1963) · Circulation Research · doi:10.1161/01.res.12.6.611 · Cited by 204
Changes in the inotropic state of the left ventricle during isometric exercise.
Grossman, W., McLaurin, L. P., Saltz, S., Paraskos, J. A., Dalen, J. E., & Dexter, L. (1973) · Heart · doi:10.1136/hrt.35.7.697 · Cited by 111
Regulation of Cardiac Contraction
Ross, J., & Sobel, B. E. (1972) · Annual Review of Physiology · doi:10.1146/annurev.ph.34.030172.000403 · Cited by 61
Quarry, V. M., & Spodick, D. H. (1974) · Circulation · doi:10.1161/01.cir.49.5.905 · Cited by 49
Cardiocirculatory responses to exercise: Physiologic study by noninvasive techniques
Pigott, V. M., Spodick, D. H., Rectra, E. H., et al. (1971) · American Heart Journal · doi:10.1016/0002-8703(71)90332-2 · Cited by 43
SAWAYAMA, T., OCHIAI, M., MARUMOTO, S., MATSUURA, T., & NIKI, I. (1969) · Circulation · doi:10.1161/01.cir.40.3.327 · Cited by 41
The continuous measurement of arterial pulse wave velocity
Weltman, G., Sullivan, G., & Bredon, D. (1964) · Medical & Biological Engineering & Computing · doi:10.1007/bf02484213 · Cited by 31
Cited by
Positive emotions speed recovery from the cardiovascular sequelae of negative emotions
L. Fredrickson, B., & Levenson, R. W. (1998) · Cognition and Emotion · doi:10.1080/026999398379718 · Cited by 1,592
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“In the first and larger group of studies, the distal waveform was measured by placing a nonflexible pressure sensor over the radial artery [133], [203], [204], [206], reflectance-mode”
BackgroundMethodChen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418
“The association between pulse transit time and BP was studied extensively in the field of psychophysiology (9, 11, 19, 33, 37) in the 1970s and 1980s, and more recently by Ochiai et al.”
BackgroundMethodPulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293
Metadata
- Authors
- Steptoe, A., Smulyan, H., & Gribbin, B.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1976-09
- Volume
- 13
- Issue
- 5
- Pages
- 488-493
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W1995292782
- Cited by
- 171
- References
- 15
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulse Wave Velocity and Blood Pressure Change: Calibration and Applications. https://app.cochat.ai/papers/10.1111/j.1469-8986.1976.tb00866.x
- The paper
- Steptoe, A., Smulyan, H., & Gribbin, B. (1976). Pulse Wave Velocity and Blood Pressure Change: Calibration and Applications. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1976.tb00866.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.