Pulse Wave Velocity as a Measure of Blood Pressure Change
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The use of arterial pulse wave velocity (PWV) as a continuous measure of blood pressure changes is outlined. Theoretical considerations indicate that changes in PWV reflect changes in blood pressure, and an experiment was carried out to assess this relationship. PWV along an arm artery was monitored in 26 subjects at a time when the arterial distending pressure of the limb was altered over a wide range by means of externally applied positive and negative pressures. The results show that changes in PWV reliably follow changes in blood pressure. This method can be considered suitable for studies requiring changes rather than absolute values of blood pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The velocity of pulse wave in man
Bramwell, J. C., & Hill, A. V. (1922) · Proceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character · doi:10.1098/rspb.1922.0022 · Cited by 806
Alterations with Age in the Viscoelastic Properties of Human Arterial Walls
Learoyd, B. M., & Taylor, M. G. (1966) · Circulation Research · doi:10.1161/01.res.18.3.278 · Cited by 681
The static elastic properties of the arterial wall
Bergel, D. H. (1961) · The Journal of Physiology · doi:10.1113/jphysiol.1961.sp006686 · Cited by 661
Brod, J., Fencl, V., Hejl, Z., & Jirka, J. (1959) · PubMed · Cited by 420
(1972) · Elsevier eBooks · doi:10.1016/b978-0-12-089901-2.x5001-7 · Cited by 403
Cardiovascular psychophysiology: Current issues in response mechanisms, biofeedback and methodology
(1975) · Behavior Therapy · doi:10.1016/s0005-7894(75)80033-5 · Cited by 374
The Elastic Properties of the Arterial Wall
Roy, C. S. (1881) · The Journal of Physiology · doi:10.1113/jphysiol.1881.sp000088 · Cited by 343
Influence of vascular smooth muscle on contractile mechanics and elasticity of arteries
Dobrin, P., & Rovick, A. (1969) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1969.217.6.1644 · Cited by 321
Measurement of Viscoelastic Properties of Arteries in the Living Dog
GOW, B. S., & TAYLOR, M. G. (1968) · Circulation Research · doi:10.1161/01.res.23.1.111 · Cited by 209
Static Anisotropic Elastic Properties of the Aorta in Living Dogs
Patel, D. J., Janicki, J. S., & Carew, T. E. (1969) · Circulation Research · doi:10.1161/01.res.25.6.765 · Cited by 178
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“…respect to time between the diastolic minimum and maximum first derivative with respect to time [134]; 3) a fraction of the pulse pressure [49], [135]; and (d) the intersection of the horizontal line through the minimum and the tangent line fitted through points near the maximum first derivative…”
BackgroundChen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
Smart Vest: Wearable multi-parameter remote physiological monitoring system
Pandian, P. S., Mohanavelu, K., Safeer, K. P., Kotresh, T. M., Shakunthala, D. T., Gopal, P., & Padaki, V. C. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.014 · Cited by 423
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418
“The association between pulse transit time and BP was studied extensively in the field of psychophysiology (9, 11, 19, 33, 37) in the 1970s and 1980s, and more recently by Ochiai et al.”
BackgroundGottman, J. M., Jacobson, N. S., Rushe, R. H., & Shortt, J. W. (1995) · Journal of Family Psychology · doi:10.1037/0893-3200.9.3.227 · Cited by 363
Detecting Vital Signs with Wearable Wireless Sensors
Yilmaz, T., Foster, R., & Hao, Y. (2010) · Sensors · doi:10.3390/s101210837 · Cited by 344
Pulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293
Pre‐ejection Period: Measuring Beta‐adrenergic Influences Upon the Heart
Newlin, D. B., & Levenson, R. W. (1979) · Psychophysiology · doi:10.1111/j.1469-8986.1979.tb01519.x · Cited by 275
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179
Pulse Wave Velocity and Blood Pressure Change: Calibration and Applications
Steptoe, A., Smulyan, H., & Gribbin, B. (1976) · Psychophysiology · doi:10.1111/j.1469-8986.1976.tb00866.x · Cited by 171
Self-citationRelation between heart rate and pulse transit time during paced respiration
Drinnan, M. J., Allen, J., & Murray, A. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/3/301 · Cited by 167
Blood pressure publication guidelines
Shapiro, D., Jamner, L. D., Lane, J. D., Light, K. C., Myrtek, M., Sawada, Y., & Steptoe, A. (1996) · Psychophysiology · doi:10.1111/j.1469-8986.1996.tb02103.x · Cited by 163
Self-citationPhotoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
“An alternative approach is to assess BP from the speed of pulse wave propagation [242], which increases with BP.”
The effect of local mild cold exposure on pulse transit time
Zhang, X.-Y., & Zhang, Y.-T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/008 · Cited by 40
Wippermann, C. F., Schranz, D., & Huth, R. G. (1995) · Journal of Clinical Monitoring · doi:10.1007/bf01616991 · Cited by 36
“Greater changes in blood pressure with very closely related changes in pulse wave velocity were recorded by altering the distending pressure of the limb by means of externally applied positive and negative pressures [6, 10 ].”
Method
Metadata
- Authors
- Gribbin, B., Steptoe, A., & Sleight, P.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1976-01
- Volume
- 13
- Issue
- 1
- Pages
- 86-90
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W1994171917
- Cited by
- 225
- References
- 19
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.