The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Pulse Transit Time as an Indicator of Arterial Blood Pressure
Abstract
The relationship between pulse‐arrival times and diastolic blood pressure was measured in 10 anesthetized dogs. The pulse‐arrival time was measured using the R‐wave of the electrocardiogram (ECG) as a time reference. Pulse‐transit time was also measured between the carotid and femoral pulses. Blood pressure was raised with epinephrine injected intravenously and lowered with vagal stimulation. In all cases, pulse arrival and transit times decreased with an increase in diastolic pressure for diastolic pressures ranging from 15 to 250 mmHg. The correlation between pulse‐arrival time and pressure was poorest when the ECG was used as a timing reference. The best correlation was found with true pulse‐transit time and diastolic pressure. When pulse‐transit time was used to compute pulse‐wave velocity, it was found to increase nearly linearly with blood pressure. From 90–100 mmHg, the pulse‐wave velocity increased typically by slightly less than six percent.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A key example is the measurement of pulse arrival time (PAT), defined by the time lapse between the maximum fiducial point in the ECG signal (R peak) and the corresponding minimal fiducial point in the PPG signal at valley as in Fig. 6H, as a direct correlate to systolic blood pressure (29 , 30).”
From Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care (2019) · cites this paper as [30]
Citations
Cites
Pulse Wave Velocity as a Measure of Blood Pressure Change
Gribbin, B., Steptoe, A., & Sleight, P. (1976) · Psychophysiology · doi:10.1111/j.1469-8986.1976.tb03344.x · Cited by 227
Pulse Wave Velocity and Blood Pressure Change: Calibration and Applications
Steptoe, A., Smulyan, H., & Gribbin, B. (1976) · Psychophysiology · doi:10.1111/j.1469-8986.1976.tb00866.x · Cited by 172
THE EFFECT OF BLOOD PRESSURE ALTERATION ON THE PULSE WAVE VELOCITY
Nye, E. R. (1964) · Heart · doi:10.1136/hrt.26.2.261 · Cited by 103
Steptoe, A. (1976) · Psychophysiology · doi:10.1111/j.1469-8986.1976.tb00875.x · Cited by 45
Bramwell, J. C. (1924) · QJM · doi:10.1093/qjmed/os-17.67.225 · Cited by 8
Research works printed but not linked: 4
- Bazett H. C, Measurement of pulse wave velocity, American Journal of Physiology, 63, 1922
- Bramwell J. G., 1923, The effect of blood pressure on the extensibility of the human artery, Heart, 10, 289
- Geddes L. A., 1969, Pulse wave velocity as a continuous indicator of indirect blood pressure, Proceedings of the 14th Annual AA Ml Meeting, 14, 89
- McSwiney B. A., 1924, The effect of variations of blood pressure on pulse wave‐velocity (in man), Journal of Physiology, 49, 217
Cited by
Sorted by citations
Items 201–293 of 293
The Design And Clinical Use Of A Reflective Brachial Photoplethysmograph
Maguire, M. F., & Ward, T. E. (2002) · Maynooth University ePrints and eTheses Archive (Maynooth University) · Cited by 6
Feasibility of a Cardiac Scale in Measuring Blood Pressure
Yazdi, D., Patel, S., Ozonat, K., Fudim, M., Smith, S., & Centen, C. (2022) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-022-10243-y · Cited by 5
Douniama, C., Sauter, C. U., & Couronné, R. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03882-2_571 · Cited by 5
Nonintrusive measurement of biological signals for ubiquitous healthcare
Park, K. S. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334000 · Cited by 5
Pulse Wave Velocity Techniques
Li, J. (2019) · Springer eBooks · doi:10.1007/978-3-030-24701-0_6 · Cited by 5
Noncontact Monitoring of Relative Changes in Blood Pressure Using Microwave Radar Sensors
Suzuki, S. V., Sun, G., Hoshiga, M., Kotani, K., & Asao, T. (2022) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2022.151006 · Cited by 5
Zikich, D., & Žikić, D. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-89208-3_277 · Cited by 5
Yen, C.-T., Chang, S., & Cai, C.-Y. (2021) · Journal of Nanomaterials · doi:10.1155/2021/6613817 · Cited by 5
Cardiovascular variability and introversion/extroversion, neuroticism and psychoticism
Burdick, J. A., Dyck, B. V., & Bargen, W. J. V. (1982) · Journal of Psychosomatic Research · doi:10.1016/0022-3999(82)90046-0 · Cited by 5
Ding, X. (2019) · Springer eBooks · doi:10.1007/978-3-030-24701-0_9 · Cited by 5
Estimation of systolic blood pressure variations from pulse arrival time using a narrow-band filter
Chen, W., Kobayashi, T., Togawa, T., Ichikawa, S., & Takeuchi, Y. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1999.802297 · Cited by 5
Continuous blood pressure prediction based on GAF-driven multimodal PPG and ECG signal fusion
Ma, S., Yang, W., (118834), C. P., Zhao, Z., & Wang, H. (2025) · Measurement · doi:10.1016/j.measurement.2025.118738 · Cited by 4
Calibration‐free blood pressure estimation based on a convolutional neural network
Cho, J.-W., Shin, H., & Choi, A. (2023) · Psychophysiology · doi:10.1111/psyp.14480 · Cited by 4
Zeng, Y., Zhu, Y., Song, X., Wang, Q., Yang, J., & Wang, W. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3557771 · Cited by 4
Continuous blood pressure prediction using pulse features and Elman neural networks
Wang, Y., Si, Y., Liu, L., & Zhang, J. (2017) · IEEE International Conference on Communication Technology (ICCT) · doi:10.1109/icct.2017.8359981 · Cited by 4
Single-Cycle Pulse Signal Recognition Based on One-Dimensional Deep Convolutional Neural Network
Chen, J., Geng, X., Yao, F., Liao, X., Zhang, Y., & Wang, Y. (2024) · Electronics · doi:10.3390/electronics13030511 · Cited by 4
Pulse Arrival Time Is Associated With Hemorrhagic Volume in a Porcine Model: A Pilot Study
Booth, G. J., Cole, J., Geiger, P., Adams, J., Barnhill, J., & Hughey, S. B. (2021) · Military Medicine · doi:10.1093/milmed/usab069 · Cited by 4
A Deep Learning-Based Continuous Blood Pressure Measurement by Dual Photoplethysmography Signals
Yen, C.-T., Chang, S., Liao, J.-X., & Huang, Y.-K. (2021) · Computers, materials & continua/Computers, materials & continua (Print) · doi:10.32604/cmc.2022.020493 · Cited by 4
Solbiati, S., Buffoli, A., Megale, V., Damato, G., Lenzi, B., Langfelder, G., & Caiani, E. G. (2021) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb52898.2021.9657564 · Cited by 4
Noninvasive Blood Pressure Prediction Based on Dual Encoder U-Net
Sun, Q. L., Chen, P., Zhang, J., Xia, Y., & Wang, B. (2023) · International Conference on Computer Research and Development · doi:10.1109/iccrd56364.2023.10080810 · Cited by 4
Smart sensing of cardiovascular physiological information from soles without direct skin contact
Kato, Y., Nambu, M., Imura, M., Kuroda, Y., & Oshiro, O. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347314 · Cited by 4
Redman, S., & Dutch, J. (1983) · Physiological Psychology · doi:10.3758/bf03326775 · Cited by 4
Quantum User Authentication with Nonentanglement-Based QKD Protocol
Yang, K., Huang, L., & Yang, W. (2007) · International Conference on Computer Sciences and Convergence Information Technology · doi:10.1109/iccit.2007.136 · Cited by 4
Lin, Y., Ko, P. C.-I., WANG, H. Y., Lu, T., Chen, Y. Y., Jan, I.-C., Jan, G. J., & Chou, N. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403970 · Cited by 4
Non-invasive Continuous Blood Pressure Monitoring Based on PWTT
Hassan, M. K. A., Mashor, . Y., Saad, A. R. M., & Mohamed, M. S. (2011) · Journal of Advanced Computer Science & Technology · Cited by 4
Capacitive-Coupled ECG Measurement and Its Applications for Ubiquitous Healthcare
Kim, K. K., Lim, Y. G., Kim, J.-S., & Park, K. S. (2007) · International Conference on Computer Sciences and Convergence Information Technology · doi:10.1109/iccit.2007.208 · Cited by 4
A Non-invasive Continuous Cardiac Output Measurement Method Utilizing ECG and SpO_2 Pulse Wave
Sugo, Y., Akiyama, T., Takeda, S., & Ishihara, H. (2005) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/ikakikaigaku.75.2_63 · Cited by 4
Snoring and sleep apnea in children
Liukkonen, K. (2011) · Työväentutkimus Vuosikirja · Cited by 4
Cardiovascular changes associated with sexual arousal and orgasm in men
Graber, B., Balogh, S. E., Fitzpatrick, D. F., & Hendricks, S. E. (1988) · Sexual Abuse · doi:10.1007/bf00851611 · Cited by 3
Shin, H. (2022) · Psychophysiology · doi:10.1111/psyp.14173 · Cited by 3
Fu, Z., Song, X., Qin, T., Chen, Y., & Ding, X. (2024) · Physiological Measurement · doi:10.1088/1361-6579/ad8299 · Cited by 3
Development and Evaluation of a Low Cost Cuffless Systolic Blood Pressure Device
Güttler, J., Chair of Building Realization and Robotics, T. U. M., Karim, M., Georgoulas, C., & Bock, T. A. (2017) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2017.p0317 · Cited by 3
Machine Learned Pulse Transit Time (MLPTT) Measurements from Photoplethysmography
Mehrgardt, P., Khushi, M., Withana, A. I., & Poon, S. K.-S. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-63836-8_5 · Cited by 3
潘, 睿. (2023) · Modeling and Simulation · doi:10.12677/mos.2023.123238 · Cited by 3
A NOVEL CONTINUOUS AND NONINVASIVE MEASUREMENT FOR BLOOD PRESSURE BASED ON PHOTOPLETHYSMOGRAPHY
Li, X., LI, X., Xu, J., Tan, H., & YUAN, M. (2016) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519417500440 · Cited by 3
A 73 μW single channel Photoplethysmography-based Blood Pressure Estimation Processor
Rehman, A., Altaf, M. A. B., & Saadeh, W. (2022) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas48785.2022.9937690 · Cited by 3
Cardiovascular Changes Associated With Sexual Arousal and Orgasm in Men
Graber, B., Balogh, S. E., Fitzpatrick, D. F., & Hendricks, S. E. (1991) · Sexual Abuse · doi:10.1177/107906329100400204 · Cited by 3
Yin, M., Miyazaki, S., Itasaka, Y., SHIBATA, Y., TANAKA, T., Abe, T., Miyoshi, A., & Ishikawa, K. (2004) · Sleep and Biological Rhythms · doi:10.1111/j.1479-8425.2004.00148.x · Cited by 3
Signal Enhancement Applied to Pulse Transit Time Measurement
He, X. (2016) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2016-11323 · Cited by 3
Arousal: Ontology, Functional Anatomy, Methodology, and Consequences
Katz, E. S. (2012) · Humana Press eBooks · doi:10.1007/978-1-60761-725-9_8 · Cited by 2
Continuous blood pressure prediction based on hierarchical adaptive algorithm
Jia, D., & Yin, W. (2020) · IEEE Information Technology, Networking, Electronic and Automation Control Conference (ITNEC) · doi:10.1109/itnec48623.2020.9084725 · Cited by 2
Blood pressure monitoring from naturally recorded speech sounds: advancements and future prospects
Arı, F., Ankışhan, H., Frederick, B. B., Hocke, L. M., & Erdoğan, S. B. (2025) · Speech Communication · doi:10.1016/j.specom.2025.103255 · Cited by 2
A Novel Method for Calibration-Based Cuff-Less Blood Pressure Estimation
Li, Z., Yan, C., Zhao, W., Hu, J. F., Jia, D., Wang, H., & You, T. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857373 · Cited by 2
A telemedicine system to detect pre-eclampsia
Williams, G., Jones, G. R., & Doughty, K. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.757814 · Cited by 2
Chen, X., Li, Y., Zhang, Y., & Deng, N. (2015) · International Symposium on Bioelectronics and Bioinformatics (ISBB) · doi:10.1109/isbb.2015.7344936 · Cited by 2
Design and Implementation of a Non-invasive and Cuff-less Arterial Blood Pressure Monitoring System
Anvari, S. M., Kayvanpour, A. H., Tadi, M. J., Koivisto, T., Yazdchi, M., & Nayebpour, S. M. H. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.325-471 · Cited by 2
The Recognition and Classification of Stress Base on Pulse Transit Time Series
Chen, C., Liu, G., & Wen, W. (2017) · International Conference on Compute and Data Analysis (ICCDA) · doi:10.1145/3093241.3093266 · Cited by 2
A New Blood Pressure Estimation Method Based on Neural Network Algorithm Model
Lu, Q., & Dai, E. (2018) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/382/5/052027 · Cited by 2
Poliński, A., Czuszyński, K., & Kocejko, T. (2018) · Conference on Human System Interactions · doi:10.1109/hsi.2018.8430971 · Cited by 2
Esmaelpoor, J., Sanat, Z. M., & Moradi, M. H. (2021) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2020-0197 · Cited by 2
Maguire, M. F., Markham, C. H., & Ward, T. E. (2001) · Maynooth University ePrints and eTheses Archive (Maynooth University) · Cited by 2
Ali, N. F., Al-Nashash, H. A., Elfadel, I. M., & Atef, M. (2025) · IEEE Access · doi:10.1109/access.2025.3639253 · Cited by 1
Zhang, Z., Qu, P., & Tang, H. X. (2026) · Sensors · doi:10.3390/s26154676 · Cited by 1
Arjomand, A., Boudesh, A., Bayatmakou, F., Krylov, G., Kent, K. B., & Mohammadi, A. (2026) · Applied Soft Computing · doi:10.1016/j.asoc.2026.116316 · Cited by 1
Non-Invasive Blood Pressure Estimation Enhanced by Capillary Refill Time Modulation of PPG Signals
Yin, Q., Chen, Y., Lin, L., Wang, D., & Sun, S. (2026) · Sensors · doi:10.3390/s26010345 · Cited by 1
Chiang, A. A.-P., Lee‐Iannotti, J. K., Torstrick, B., Berry, R. B., & Collop, N. A. (2026) · Journal of Clinical Sleep Medicine · doi:10.1007/s44470-026-00088-6 · Cited by 1
Park, G. N., Sung, W. Y., Seo, S. W., Hong, S. Y., Yang, Y. M., Lee, J. Y., Sung, N. J., & Yang, H. B. (2009) · The Korean Journal of Critical Care Medicine · doi:10.4266/kjccm.2009.24.1.11 · Cited by 1
James, M., Gregori, S., Fayek, D., & Ontario, N. (2008) · Cited by 1
Multi agent system for estimation of cardiovascular parameters
Al-Jaafreh, M. O., & Al-Jumaily, A. A. (2005) · International Conference on Computers, Communications, and Signal Processing with Special Track on Biomedical Engineering (CCSP) · doi:10.1109/ccsp.2005.4977210 · Cited by 1
Exploring pulse transit time as a potential indicator of blood pressure: a scientific inquiry
Omari, T., Benali, R., Dib, N., & Behadada, O. (2024) · STUDIES IN HEALTH SCIENCES · doi:10.54022/shsv5n4-031 · Cited by 1
Hemodynamic Aspects of Vessel Wall Imaging: 4D Flow
van Ooij, P., & Markl, M. (2019) · Springer eBooks · doi:10.1007/978-3-030-25249-6_16 · Cited by 1
Cuffless Systolic Blood Pressure Estimation Using Photoplethysmography Signal
Chatterjee, A., Mitra, M., & Pal, S. (2019) · International Conference on Computing, Power and Communication Technologies (GUCON) · Cited by 1
Sakajiri, Y., & Ueno, A. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176548 · Cited by 1
Real-time, Cuff-less and Non-invasiveBlood Pressure Monitoring
Abolhasani, A., Mousazadeh, M., & Khoei, A. (2020) · Informacije MIDEM - Journal of Microelectronics Electronic Components and Materials · doi:10.33180/infmidem2020.202 · Cited by 1
Wandel, T., Hausherr, D. P., & Berben, D. (2022) · Sensors · doi:10.3390/s22218295 · Cited by 1
Ishida, K., Kimata, N., 坂上貴光, Minematsu, Y., Oka, T., Miwa, Y., Kawaguchi, K., Sato, A., Kaneko, I., Sato, Y., et al. (2003) · Nihon Toseki Igakkai Zasshi · doi:10.4009/jsdt.36.1553 · Cited by 1
A Correlation Study on the Features of Photoplethysmographic Signals
Gu, Y., & Zhang, Y. (2006) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmd.2004.1689574
Low cost thermal measurement of pulse-transit-time
James, M., Gregori, S., & Fayek, D. (2008) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2008.4564846
A single chip solution for pulse transmit time measurement
Knezevic, S., Stojanovic, R. D., Ašanin, B., & Karadaglić, D. (2013) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2013.6701625
Arterial pulse transit time and ECG-initiated transit time: The form of the conditioned responses
Redman, S., & Dutch, J. (1984) · Physiological Psychology · doi:10.3758/bf03332192
System for thermal measurement of pulse-transit-time
James, M., Gregori, S., & Fayek, D. (2008) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2008.4541616
Roytvarf, A. A., & Shusterman, V. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912668
Chen, X.-W., Li, Y., Zhang, Y., & Deng, N. (2015) · CRC Press eBooks · doi:10.1201/b19238-74
Fall detectors for people with dementia
Leake, J. (2015) · The University of Bath Online Publications Store (The University of Bath)
Quality Level Classification of ECG Measured using Non-Constraint Approach
Kim, Y. J., Heo, J., Park, K., & Kim, S. (2016) · Journal of Biomedical Engineering Research · doi:10.9718/jber.2016.37.5.161
AEVUM: Personalized Health Monitoring System
Swaminathan, A. (2018) · RIT Scholar Works (Rochester Institute of Technology)
Motion Compensated Continuous Blood Pressure Measurements Using Recurrent Neural Networks
Ghosh, S. (2018) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r34t6fj5m
Iwagaki, S., Takahashi, Y., Imai, N., Chiaki, R., Asai, K., & Matsui, M. (2020) · Fetal Diagnosis and Therapy · doi:10.1159/000511476
Physiological Signal Variability Analysis Based on the Largest Lyapunov Exponent
LI-Liping, L.-C. (2009)
A Novel Strategy for Signal Reconstruction of Noisy Segments in Photoplethysmographic Recordings
Vraka, A., Quesada, A., Hornero, F., Martínez‐Rodrigo, A., Alcaraz, R., & Rieta, J. J. (2022) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb55594.2022.9991390
Lu, E., Li, H., Wang, S., Xiang, J., & He, L. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4856226
Continuous Blood Pressure Estimation via Gaussian Regression Model with the Bayesian Optimization
Lin, Z. (2024) · International Conference on Advanced Algorithms and Control Engineering (ICAACE) · doi:10.1109/icaace61206.2024.10549699
A Multi-Wavelength Optical Sensing Framework for Calibration-Free Wearable Blood Pressure Monitoring
Hamid, T., Flores, P., Byun, J., Chen, X., Zhang, H., Quinn, K., & Watson, A. (2025) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp49660.2025.10890529
Hashemi, M., Amra, B., Mirjani, M. H., Schöbel, C., & Penzel, T. (2025) · doi:10.32592/smmr.202501.04.02
Anderson, C. P., Layec, G., & Park, S. (2025) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00513.2025
Continuous Blood Pressure Measurement Guided by Physiological Mechanisms
He, J., & Wu, H. (2025) · IEEE International Conference on Artificial Intelligence Circuits and Systems (AICAS) · doi:10.1109/aicas64808.2025.11173166
Ali, N. F., Tariq, U., & Al-Nashash, H. A. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3673727
Non-invasive Evaluation of Cardiovascular Dynamics Using Statistical Learning Tools
Aguirre, N. A. (2023) · theses.fr (ABES) · doi:10.70675/0d0519bfzb38bz4b9fzab46z8a255d75d280
Yu, Y., & Lowe, A. (2026) · Hypertension Research · doi:10.1038/s41440-026-02651-3
Berg, K., Kantelhardt, J. W., Glos, M., Penzel, T., Wessel, N., & Bartsch, R. P. (2026) · PLoS ONE · doi:10.1371/journal.pone.0339755
EarBP: Earbuds-Based Noninvasive Blood Pressure Elevation Monitoring Using Pulse Transit Time
Morshed, M. B., Rahman, M. M., Islam, M. S., Hahn, J.-O., Zhu, L., & Desai, S. (2026) · IEEE Internet of Things Journal · doi:10.1109/jiot.2026.3716618
Shang, Y., & Zhang, N. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7227883
Metadata
- Authors
- Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A.
- Affiliations
- Purdue University West Lafayette (US)
- Corresponding author
- Geddes, L. A.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1981-01
- Volume
- 18
- Issue
- 1
- Pages
- 71-74
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2163704183
- Cited by
- 293
- References
- 5
- Citations by year
- 2026: 10 · 2025: 13 · 2024: 13 · 2023: 14 · 2022: 15 · 2021: 22 · 2020: 22 · 2019: 18 · 2018: 23 · 2017: 12 · 2016: 14 · 2015: 8 · 2014: 11 · 2013: 3 · 2012: 8
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Psychophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- pulse transit time, arterial blood pressure, diastolic blood pressure, pulse arrival time, pulse wave velocity, epinephrine, vagus nerve stimulation, dogs
- MeSH terms
- Animals, Blood Pressure, Dogs, Electrocardiography, Pulse
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review