Colorimetric protein assay techniques
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
There has been an increase in the number of colorimetric assay techniques for the determination of protein concentration over the past 20 years. This has resulted in a perceived increase in sensitivity and accuracy with the advent of new techniques. The present review considers these advances with emphasis on the potential use of such technologies in the assay of biopharmaceuticals. The techniques reviewed include Coomassie Blue G‐250 dye binding (the Bradford assay), the Lowry assay, the bicinchoninic acid assay and the biuret assay. It is shown that each assay has advantages and disadvantages relative to sensitivity, ease of performance, acceptance in the literature, accuracy and reproducibility/coefficient of variation/laboratory‐to‐laboratory variation. A comparison of the use of several assays with the same sample population is presented. It is suggested that the most critical issue in the use of a chromogenic protein assay for the characterization of a biopharmaceutical is the selection of a standard for the calibration of the assay; it is crucial that the standard be representative of the sample. If it is not possible to match the standard with the sample from the perspective of protein composition, then it is preferable to use an assay that is not sensitive to the composition of the protein such as a micro‐Kjeldahl technique, quantitative amino acid analysis or the biuret assay. In a complex mixture it might be inappropriate to focus on a general method of protein determination and much more informative to use specific methods relating to the protein(s) of particular interest, using either specific assays or antibody‐based methods. The key point is that whatever method is adopted as the ‘gold standard’ for a given protein, this method needs to be used routinely for calibration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331
Bradford, M. M. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90527-3 · Cited by 255,302
Measurement of protein using bicinchoninic acid
Smith, P. K., Krohn, R. I., Hermanson, G. T., Mallia, A. K., Gartner, F. H., Provenzano, M. D., Fujimoto, E. K., Goeke, N. M., Olson, B. J., & Klenk, D. C. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90442-7 · Cited by 18,482
DETERMINATION OF SERUM PROTEINS BY MEANS OF THE BIURET REACTION
Gornall, A. G., Bardawill, C. J., & David, M. M. (1949) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)57021-6 · Cited by 16,158
A simplification of the protein assay method of Lowry et al. which is more generally applicable
Peterson, G. L. (1977) · Analytical Biochemistry · doi:10.1016/0003-2697(77)90043-4 · Cited by 8,524
Hartree, E. F. (1972) · Analytical Biochemistry · doi:10.1016/0003-2697(72)90094-2 · Cited by 5,516
[73] Spectrophotometric and turbidimetric methods for measuring proteins
Layne, E. (1957) · Methods in Enzymology · doi:10.1016/s0076-6879(57)03413-8 · Cited by 3,294
A rapid, sensitive, and versatile assay for protein using Coomassie brilliant blue G250
Sedmak, J. J., & Grossberg, S. E. (1977) · Analytical Biochemistry · doi:10.1016/0003-2697(77)90428-6 · Cited by 3,030
ON TYROSINE AND TRYPTOPHANE DETERMINATIONS IN PROTEINS
Folin, O., & Ciocalteu, V. (1927) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)84277-6 · Cited by 2,946
Hydrogen Ion Buffers for Biological Research*
Good, N. E., Winget, G. D., Winter, W., Connolly, T. N., Izawa, S., & Singh, R. M. M. (1966) · Biochemistry · doi:10.1021/bi00866a011 · Cited by 2,762
Research works printed but not linked: 72
- Young E.G., 1963, Comprehensive Biochemistry, vol. 7, 1
- Henry P.J., 1964, Clinical Chemistry, Principles and Practice, 175
- 10.1016/0003-2697(63)90156-8 · doi:10.1016/0003-2697(63)90156-8
- 10.1177/000456329102800604 · doi:10.1177/000456329102800604
- Stevens L., 1992, Enzyme Assays: A Practical Approach, 317
- Price N.C., 1996, Enzyme LabFax, 34
- Rosenfeld L., 1982, Origins of Clnical Chemistry
- Engel H., 1995, Eur. J. Clin. Chem. Clin. Biochem., 33, 239
- 10.1006/abio.1993.1273 · doi:10.1006/abio.1993.1273
- 10.1006/abio.1996.0453 · doi:10.1006/abio.1996.0453
- 10.1006/abio.1994.1310 · doi:10.1006/abio.1994.1310
- Goren M.P., 1986, Clin. Chem., 32, 386, 10.1093/clinchem/32.2.386 · doi:10.1093/clinchem/32.2.386
- 10.1016/0003-2697(79)90736-X · doi:10.1016/0003-2697(79)90736-x
- Barnes D.B., 1985, Clin. Chem., 31, 2018, 10.1093/clinchem/31.12.2018 · doi:10.1093/clinchem/31.12.2018
- 10.1111/j.1423-0410.1992.tb05096.x · doi:10.1111/j.1423-0410.1992.tb05096.x
- 10.1093/clinchem/30.3.443 · doi:10.1093/clinchem/30.3.443
- 10.1006/biol.1995.0048 · doi:10.1006/biol.1995.0048
- 10.1002/food.19910350716 · doi:10.1002/food.19910350716
- 10.1016/S0009-9120(97)00038-6 · doi:10.1016/s0009-9120(97)00038-6
- Dilena B.A., 1983, Clin. Chem., 29, 553, 10.1093/clinchem/29.3.553 · doi:10.1093/clinchem/29.3.553
- 10.3109/00313029009063786 · doi:10.3109/00313029009063786
- 10.1016/0003-2697(86)90339-8 · doi:10.1016/0003-2697(86)90339-8
- 10.1016/S0021-9258(18)85898-7 · doi:10.1016/s0021-9258(18)85898-7
- 10.1006/abio.1994.1276 · doi:10.1006/abio.1994.1276
- 10.1016/S1081-1206(10)63019-0 · doi:10.1016/s1081-1206(10)63019-0
- 10.1007/s001050050514 · doi:10.1007/s001050050514
- 10.1016/S1081-1206(10)63271-1 · doi:10.1016/s1081-1206(10)63271-1
- 10.1076/ceyr.16.4.279.10693 · doi:10.1076/ceyr.16.4.279.10693
- Feldt‐Rasmussen U., 1996, Annales Biol. Clin., 54, 343
- Wysocki A.B., 1996, J. Wound Ostomy Contin. Nursing, 23, 283
- 10.1620/tjem.178.137 · doi:10.1620/tjem.178.137
- 10.1006/abio.1996.0024 · doi:10.1006/abio.1996.0024
- 10.1111/j.1399-3011.1986.tb01818.x · doi:10.1111/j.1399-3011.1986.tb01818.x
- Johnson J.A., 1978, Clin. Chem., 24, 1931, 10.1093/clinchem/24.11.1931 · doi:10.1093/clinchem/24.11.1931
- 10.1016/0003-2697(84)90059-9 · doi:10.1016/0003-2697(84)90059-9
- Wilsott D.K., 1987, Clin. Chem., 33, 2100, 10.1093/clinchem/33.11.2100 · doi:10.1093/clinchem/33.11.2100
- 10.1076/ceyr.16.6.614.5077 · doi:10.1076/ceyr.16.6.614.5077
- 10.1016/S0041-0101(96)00174-2 · doi:10.1016/s0041-0101(96)00174-2
- 10.1006/abio.1996.0203 · doi:10.1006/abio.1996.0203
- 10.1016/0003-2697(73)90210-8 · doi:10.1016/0003-2697(73)90210-8
- 10.1016/0003-2697(91)90210-K · DOI
- 10.1006/abio.1993.1300 · doi:10.1006/abio.1993.1300
- Kader A., 1997, Clin. Chem., 43, 2201, 10.1093/clinchem/43.11.2201 · doi:10.1093/clinchem/43.11.2201
- 10.1016/0003-2697(90)90520-J · doi:10.1016/0003-2697(90)90520-j
- 10.1016/0003-2697(89)90238-8 · doi:10.1016/0003-2697(89)90238-8
- 10.1016/0003-2697(90)90574-S · doi:10.1016/0003-2697(90)90574-s
- 10.1006/abio.1993.1077 · doi:10.1006/abio.1993.1077
- 10.1006/abio.1993.1134 · doi:10.1006/abio.1993.1134
- 10.1007/BF02922025 · doi:10.1007/bf02922025
- 10.1016/0003-2697(90)90032-5 · doi:10.1016/0003-2697(90)90032-5
- 10.1163/156856295X00788 · doi:10.1163/156856295x00788
- 10.3109/00365519309092582 · doi:10.3109/00365519309092582
- 10.1006/abio.1994.1226 · doi:10.1006/abio.1994.1226
- 10.1076/ceyr.16.5.503.7049 · doi:10.1076/ceyr.16.5.503.7049
- 10.1016/S0278-2391(97)90583-8 · doi:10.1016/s0278-2391(97)90583-8
- 10.1021/np960024c · doi:10.1021/np960024c
- 10.1530/jrf.0.1070229 · doi:10.1530/jrf.0.1070229
- Buija J., 1996, Eur. Arch. Oto-Rhino-Laryngol., 253, 252
- Gerbaut L., 1986, Clin. Chem., 32, 353, 10.1093/clinchem/32.2.353 · doi:10.1093/clinchem/32.2.353
- 10.1515/bchm3.1985.366.2.979 · doi:10.1515/bchm3.1985.366.2.979
- Vik H., 1989, Ann. Allergy, 62, 87
- 10.1006/abio.1995.1074 · doi:10.1006/abio.1995.1074
- 10.1006/abio.1993.1006 · doi:10.1006/abio.1993.1006
- 10.1016/0022-1759(86)90174-2 · doi:10.1016/0022-1759(86)90174-2
- 10.1016/0091-6749(94)90372-7 · doi:10.1016/0091-6749(94)90372-7
- Bozimowski D., 1985, J. Clin. Chem. Clin. Biochem., 23, 683
- Vogel P.F., 1993, J. Parenteral Sci. Technol., 47, 276
- Akers J., 1993, J. Parenteral Sci. Technol., 47, 281
- 10.1038/nbt0394-259 · doi:10.1038/nbt0394-259
- McDaniel R.J.(1996)Sci. Comput. Automation May 26–28 · doi:10.1145/242224.242256
- Doumas B.T., 1981, Clin. Chem., 27, 1652
- 10.1021/ac970926y · doi:10.1021/ac970926y
Cited by
Polymer surface modification for the attachment of bioactive compounds
Goddard, J. M., & Hotchkiss, J. H. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.04.002 · Cited by 1,379
Protein measurements of microalgal and cyanobacterial biomass
González López, C. V., García, M. D. C. C., Fernández, F. G. A., Bustos, C. S., Chisti, Y., & Sevilla, J. M. F. (2010) · Bioresource Technology · doi:10.1016/j.biortech.2010.04.077 · Cited by 652
Milo, R. (2013) · BioEssays · doi:10.1002/bies.201300066 · Cited by 614
“Various techniques were used throughout the years to measure protein abundances ranging from colorimetric [1] and spectroscopic [2] to amino acid analysis and radioimmunoassays.”
MethodChapter 8 Quantitation of Protein
Noble, J. E., & Bailey, M. J. A. (2009) · Methods in Enzymology · doi:10.1016/s0076-6879(09)63008-1 · Cited by 492
“The exact mechanism is however still not fully understood (Sapan et al., 1999).”
BackgroundProteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
Antidepressant‐like effects of cannabidiol in mice: possible involvement of 5‐HT1Areceptors
Zanelati, T., Biojone, C., Moreira, F., Guimarães, F., & Joca, S. (2010) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2009.00521.x · Cited by 366
Sáez-Plaza, P., Michałowski, T., Navas, M. J., Asuero, A. G., & Wybraniec, S. (2013) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2012.751786 · Cited by 358
Does the nanometre scale topography of titanium influence protein adsorption and cell proliferation?
Cai, K., Bossert, J., & Jandt, K. D. (2006) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2006.02.016 · Cited by 357
Biomass for thermochemical conversion: targets and challenges
Tanger, P., Field, J. L., Jahn, C. E., DeFoort, M. W., & Leach, J. E. (2013) · Frontiers in Plant Science · doi:10.3389/fpls.2013.00218 · Cited by 283
Mroz, P., Pawlak, A., Satti, M., Lee, H., Wharton, T., Gali, H., Sarna, T., & Hamblin, M. R. (2007) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2007.05.005 · Cited by 257
Total Protein Methods and Their Potential Utility to Reduce the Risk of Food Protein Adulteration
Moore, J. C., DeVries, J. W., Lipp, M., Griffiths, J. C., & Abernethy, D. R. (2010) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/j.1541-4337.2010.00114.x · Cited by 249
Recent approaches for optical smartphone sensing in resource-limited settings: a brief review
McCracken, K. E., & Yoon, J.-Y. (2016) · Analytical Methods · doi:10.1039/c6ay01575a · Cited by 216
Kaushik, R., Saran, S., Isar, J., & Saxena, R. K. (2006) · Journal of Molecular Catalysis B: Enzymatic · doi:10.1016/j.molcatb.2006.02.019 · Cited by 200
Comprehensive Overview of Bottom-Up Proteomics Using Mass Spectrometry
Jiang, Y., Rex, D. A. B., Schuster, D., Neely, B. A., Rosano, G. L., Volkmar, N., Momenzadeh, A., Peters-Clarke, T. M., Egbert, S. B., Kreimer, S., et al. (2024) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.3c00068 · Cited by 190
Cortés-Ríos, J., Zárate, A. M., Figueroa, J. D., Medina, J., Fuentes-Lemus, E., Rodríguez-Fernández, M., Aliaga, M., & López-Alarcón, C. (2020) · Analytical Biochemistry · doi:10.1016/j.ab.2020.113904 · Cited by 177
Kondo, T., & Hirohashi, S. (2006) · Nature Protocols · doi:10.1038/nprot.2006.421 · Cited by 170
Serum proteins and their diagnostic utility in veterinary medicine: a review
Tothova, C., Nagy, O., & Kovac, G. (2016) · Veterinární medicína · doi:10.17221/19/2016-vetmed · Cited by 163
“The disadvantages of the Lowry method are the sensitivity to the amino acid composition of the protein and interference by a range of substances, including buffers, drugs, and nucleic acids (Sapan et al. 1999).”
MethodAddis, R., Campesi, I., Fois, M., Capobianco, G., Dessole, S., Fenu, G., Montella, A., Cattaneo, M. G., Vicentini, L. M., & Franconi, F. (2014) · Biology of Sex Differences · doi:10.1186/s13293-014-0018-2 · Cited by 104
Spray-dried snail mucus as raw material with potential for chronic wound treatment
Tasevska, T., Glavas Dodov, M., Shalabalija, D., Mihailova, L., Polenakovic, R., & Simonoska Crcarevska, M. (2022) · Macedonian Pharmaceutical Bulletin · doi:10.33320/maced.pharm.bull.2022.68.03.153 · Cited by 2
Metadata
- Authors
- Sapan, C. V., Lundblad, R. L., & Price, N. C.
- Venue
- Biotechnology and Applied Biochemistry
- Publisher
- Wiley
- Published
- 1999-04
- Volume
- 29
- Issue
- 2
- Pages
- 99-108
- ISSN
- 0885-4513 (ISSN-L)
- 1470-8744
- OpenAlex
- W1946747292
- Cited by
- 505
- References
- 72
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.