CoChat

Fluctuations in accommodation: a review

Charman, W.N., Heron, G. · 1988 · Ophthalmic and Physiological Optics
Cited by 262

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

When a young observer attempts to accommodate steadily on a fixed stimulus, the norminally steady‐state response shows small instabilities or fluctuations (sometimes termed microfluctuations or oscillations). These fluctuations typically have an amplitude of a few tenths of a dioptre and a frequency spectrum extending up to a few Hertz. The properties of these fluctuations are described for various viewing conditions: pupil diameter, target vergence, target form, target contrast, and target luminance all influence the frequency spectra of the oscillations, as may anomalies of vision such as amblyopia. The possible roles that the fluctuations might play in the function of the accommodative system are discussed. It is suggested that the higher frequency components around 2 H z may arise from the mechanical and elastic characteristics of the lens, zonule and ciliary body. Components at lower frequencies (<0.5 Hz) may be of more significance in the function of the accommodative control system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1475-1313.1988.tb01031.x

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 67

  1. 10.1097/00006324-196008000-00004 · doi:10.1097/00006324-196008000-00004
  2. 10.1364/JOSA.48.000193 · doi:10.1364/josa.48.000193
  3. Arnulf A., 1951, Les microfluctuations d' accommodation de l‘ oeil et l’ acuité visuelle pour les diamétres pupillaires naturels, C.R. Hebd. seanc. Acad. Sci. Paris, 232, 349
  4. Arnulf A., 1951, Les microfluctuations de l‘oeil et leur influence sur l’ image retinienne, C.R. Hebd. seanc. Acad. Sci. Paris, 232, 438
  5. Arnulf A., 1955, Les microfluctuations de l' oeil, Ann. d' Optique Oculaire, 3, 109
  6. Arnulf A., 1960, Contribution a l'étude des microfluctuations d'accommodation de l'oeil, Rev. Opt. (Paris), 39, 195
  7. Arnulf A., 1977, El sistema optico del ojo primer escalon de la sensacion visual, El optico profesional, 191, 13
  8. Arnulf A. Santamaria J.andBescós J.(1978)Cinematographic recording of retinal images. New contributions to the study of microfluctuations of the accommodation. In Proceedings of the ICO‐11 Conference Madrid Spain pp.47–50.
  9. 10.1088/0150-536X/12/2/004 · doi:10.1088/0150-536x/12/2/004
  10. 10.1016/0042-6989(69)90103-5 · doi:10.1016/0042-6989(69)90103-5
  11. Berny F., 1970, Optical Instruments and Techniques, 375
  12. 10.1097/00006324-198308000-00006 · doi:10.1097/00006324-198308000-00006
  13. 10.1016/0042-6989(81)90233-9 · doi:10.1016/0042-6989(81)90233-9
  14. 10.1364/JOSA.50.000738 · doi:10.1364/josa.50.000738
  15. Campbell F.W., 1960, The accommodation response of the human eye, Br. J. Physiol. Opt., 16, 188
  16. 10.1364/JOSA.49.000268 · DOI
  17. Campbell F.W., 1958, Sensitivity of the eye to differences in focus, J. Physiol. (Lond.), 143, 18P
  18. 10.1364/JOSA.49.000568 · doi:10.1364/josa.49.000568
  19. 10.1113/jphysiol.1960.sp006438 · doi:10.1113/jphysiol.1960.sp006438
  20. 10.1364/JOSA.48.000669 · doi:10.1364/josa.48.000669
  21. 10.1113/jphysiol.1959.sp006164 · doi:10.1113/jphysiol.1959.sp006164
  22. Charman W.N., 1983, Progress in Retinal Research, 1
  23. Charman W.N., 1975, A simple infra‐red optometer for accommodation studies, Br. J. Physiol. Opt., 30, 1
  24. 10.1097/00006324-197802000-00004 · doi:10.1097/00006324-197802000-00004
  25. 10.1364/JOSA.46.000060 · doi:10.1364/josa.46.000060
  26. 10.1016/0042-6989(83)90172-4 · doi:10.1016/0042-6989(83)90172-4
  27. Collins G., 1937, The Electronic Refractometer, Br. J. Physiol. Opt., 1, 30
  28. Crane H.D., 1966, A Theoretical Analysis of the Visual Accommodation System in Humans
  29. Denieul P.(1978)Dynamic study of microfluctuations of accommodation with a high sensitive infrared optometer. In Optica Hoy y Manana Proceedings of the ICO‐11 Conference Madrid pp.51–54.
  30. 10.1016/0042-6989(82)90114-6 · doi:10.1016/0042-6989(82)90114-6
  31. Denieul P., 1982, Influence de la dimension des tests sur l'accommodation, L'Optométrie, 28, 12
  32. 10.1016/0042-6989(77)90019-0 · doi:10.1016/0042-6989(77)90019-0
  33. Denieul P., 1986, Accommodation et contraste, L'Optométrie, 32, 4
  34. 10.1038/scientificamerican0764-24 · doi:10.1038/scientificamerican0764-24
  35. Fincham E. F., 1937, The mechanism of accommodation, Br. J. Ophthal. Monograph, 3
  36. 10.1113/jphysiol.1969.sp008740 · DOI
  37. 10.1113/jphysiol.1971.sp009315 · DOI
  38. 10.1113/jphysiol.1977.sp011938 · doi:10.1113/jphysiol.1977.sp011938
  39. 10.1037/e503522009-001 · doi:10.1037/e503522009-001
  40. Heron G.(1972)A Study of Accommodation using an Infra‐red Optometer.MSc Thesis University of Manchester UK .
  41. 10.1111/j.1475-1313.1986.tb01145.x · doi:10.1111/j.1475-1313.1986.tb01145.x
  42. Hung G. K., 1982, Accommodative oscillation can enhance average accommodative response: a simulation study, IEEE Trans. Syst. Man. Cybern., 12, 594, 10.1109/TSMC.1982.4308870 · doi:10.1109/tsmc.1982.4308870
  43. 10.1109/TBME.1983.325069 · doi:10.1109/tbme.1983.325069
  44. 10.1364/JOSAA.3.000223 · doi:10.1364/josaa.3.000223
  45. 10.1068/p150007 · DOI
  46. 10.1080/713818772 · doi:10.1080/713818772
  47. 10.1007/BF00410107 · doi:10.1007/bf00410107
  48. 10.1097/00006324-196808000-00001 · doi:10.1097/00006324-196808000-00001
  49. 10.1111/j.1475-1313.1988.tb01032.x · doi:10.1111/j.1475-1313.1988.tb01032.x
  50. 10.1016/0042-6989(68)90065-5 · doi:10.1016/0042-6989(68)90065-5
  51. 10.1364/JOSA.58.000570 · doi:10.1364/josa.58.000570
  52. 10.1007/BF00496877 · doi:10.1007/bf00496877
  53. 10.1007/BF01569293 · doi:10.1007/bf01569293
  54. Ripps H., 1962, The effect of pupil size on accommodation, convergence and the AC/A ratio, Invest. Ophthalmol., 1, 127
  55. Santamaria J., 1984, Dynamic recording of the binocular point spread function of the eyes optical system, Optica Applicata, 14, 341
  56. 10.1111/j.1475-1313.1984.tb00346.x · doi:10.1111/j.1475-1313.1984.tb00346.x
  57. 10.1364/JOSA.64.001512 · doi:10.1364/josa.64.001512
  58. 10.1109/TBME.1965.4502370 · doi:10.1109/tbme.1965.4502370
  59. 10.1109/TSSC.1965.300064 · doi:10.1109/tssc.1965.300064
  60. 10.1111/j.1475-1313.1984.tb00361.x · doi:10.1111/j.1475-1313.1984.tb00361.x
  61. 10.1016/0042-6989(64)90044-6 · doi:10.1016/0042-6989(64)90044-6
  62. 10.1097/00006324-197908000-00003 · doi:10.1097/00006324-197908000-00003
  63. 10.1016/0042-6989(86)90056-8 · doi:10.1016/0042-6989(86)90056-8
  64. 10.1111/j.1475-1313.1986.tb00718.x · doi:10.1111/j.1475-1313.1986.tb00718.x
  65. 10.1364/JOSA.47.000714 · doi:10.1364/josa.47.000714
  66. Whiteside T. C. D., 1957, Problems of Vision at High Altitudes, 193
  67. 10.1097/00006324-197504000-00001 · doi:10.1097/00006324-197504000-00001

Cited by

See all 262

Metadata

Authors
Charman, W. N., & Heron, G.
Venue
Ophthalmic and Physiological Optics
Published
1988-04
Volume
8
Issue
2
Pages
153-164
ISSN
  • 0275-5408 (ISSN-L)
  • 1475-1313
OpenAlex
W2132819729
Cited by
262
References
9
FWCI
3.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.