Dynamic monitoring of beating periodicity of stem cell‐derived cardiomyocytes as a predictive tool for preclinical safety assessment
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND PURPOSE Cardiac toxicity is a major concern in drug development and it is imperative that clinical candidates are thoroughly tested for adverse effects earlier in the drug discovery process. In this report, we investigate the utility of an impedance‐based microelectronic detection system in conjunction with mouse embryonic stem cell‐derived cardiomyocytes for assessment of compound risk in the drug discovery process. EXPERIMENTAL APPROACH Beating of cardiomyocytes was measured by a recently developed microelectronic‐based system using impedance readouts. We used mouse stem cell‐derived cardiomyocytes to obtain dose‐response profiles for over 60 compounds, including ion channel modulators, chronotropic/ionotropic agents, hERG trafficking inhibitors and drugs known to induce Torsades de Pointes arrhythmias. KEY RESULTS This system sensitively and quantitatively detected effects of modulators of cardiac function, including some compounds missed by electrophysiology. Pro‐arrhythmic compounds produced characteristic profiles reflecting arrhythmia, which can be used for identification of other pro‐arrhythmic compounds. The time series data can be used to identify compounds that induce arrhythmia by complex mechanisms such as inhibition of hERG channels trafficking. Furthermore, the time resolution allows for assessment of compounds that simultaneously affect both beating and viability of cardiomyocytes. CONCLUSIONS AND IMPLICATIONS Microelectronic monitoring of stem cell‐derived cardiomyocyte beating provides a high throughput, quantitative and predictive assay system that can be used for assessment of cardiac liability earlier in the drug discovery process. The convergence of stem cell technology with microelectronic monitoring should facilitate cardiac safety assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drug-induced prolongation of the QT interval
Roden, D. M. (2004) · New England Journal of Medicine · doi:10.1056/nejmra032426 · Cited by 1,965
Guide to receptors and channels (GRAC), 5th edition
Alexander, S., Mathie, A., & Peters, J. (2011) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2011.01649_1.x · Cited by 1,947 · cited 1×
“The field has adopted assays that are designed to assess the interaction of compounds with hERG K+ channels (channel nomenclature follows Alexander et al., 2011), which serves as a surrogate for TdP arrhythmia.”
MethodSomatic coding mutations in human induced pluripotent stem cells
Gore, A., Li, Z., Fung, H.-L., Young, J. E., Agarwal, S., Antosiewicz-Bourget, J., Canto, I., Giorgetti, A., Israel, M. A., Kiskinis, E., et al. (2011) · Nature · doi:10.1038/nature09805 · Cited by 1,273
hERG channel trafficking: Novel targets in drug-induced long QT syndrome
Dennis, A., Wang, L., Wan, X., & Ficker, E. (2007) · Biochemical Society Transactions · doi:10.1042/bst0351060 · Cited by 134
Cited by
Zhang, Y. S., Aleman, J., Shin, S. R., Kilic, T., Kim, D., Mousavi Shaegh, S. A., Massa, S., Riahi, R., Chae, S., Hu, N., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1612906114 · Cited by 833
Multi-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442
Navarrete, E. G., Liang, P., Lan, F., Sanchez-Freire, V., Simmons, C., Gong, T., Sharma, A., Burridge, P. W., Patlolla, B., Lee, A. S., et al. (2013) · Circulation · doi:10.1161/circulationaha.112.000570 · Cited by 302
Giacomelli, E., Bellin, M., Sala, L., van Meer, B. J., Tertoolen, L. G. J., Orlova, V. V., & Mummery, C. L. (2017) · Development · doi:10.1242/dev.143438 · Cited by 279
Drawnel, F. M., Boccardo, S., Prummer, M., Delobel, F., Graff, A., Weber, M., Gérard, R., Badi, L., Kam-Thong, T., Bu, L., et al. (2014) · Cell Reports · doi:10.1016/j.celrep.2014.09.055 · Cited by 247
“Furthermore, impedance-based monitoring (Abassi et al., 2012) revealed that the amplitude of CM beats was reduced in DM-treated cells (Figure 2H).”
Background
Metadata
- Authors
- Abassi, Y. A., Xi, B., Li, N., Ouyang, W., Seiler, A., Watzele, M., Kettenhofen, R., Bohlen, H., Ehlich, A., Kolossov, E., Wang, X., & Xu, X.
- Venue
- British Journal of Pharmacology
- Publisher
- Wiley
- Published
- 2012-02-10
- Volume
- 165
- Issue
- 5
- Pages
- 1424-1441
- ISSN
- 0007-1188 (ISSN-L)
- 1476-5381
- OpenAlex
- W1748447088
- Cited by
- 124
- References
- 4
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic monitoring of beating periodicity of stem cell‐derived cardiomyocytes as a predictive tool for preclinical safety assessment. https://app.cochat.ai/papers/10.1111/j.1476-5381.2011.01623.x
- The paper
- Abassi, Y. A., Xi, B., Li, N., Ouyang, W., Seiler, A., Watzele, M., Kettenhofen, R., Bohlen, H., Ehlich, A., Kolossov, E., Wang, X., & Xu, X. (2012). Dynamic monitoring of beating periodicity of stem cell‐derived cardiomyocytes as a predictive tool for preclinical safety assessment. British Journal of Pharmacology. https://doi.org/10.1111/j.1476-5381.2011.01623.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.