Dipole‐Source Analysis in a Realistic Head Model in Patients with Focal Epilepsy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary: Purpose: By the use of three different head models in EEG dipole analysis, we tried to model the origin of interictal and ictal epileptic activity as precisely as possible. Further, as a control, a second evaluation was made by an independent group to control for interindividual reliability of the dipole source analysis. With the realistic head model (CURRY) considering cortex, skull, and skin segmentation, the spike source was located. Methods: In five patients with mesial temporal epileptogenesis, confirmed by successful epilepsy surgery, the spike source was close to the hippocampus, with a mean distance of the dipole source from the hippocampus of 13.6 mm (range, 9–17.2 mm). In one case the ictal EEG also could be analyzed and resulted in a dipole‐source localization comparable to the interictal source. Results: In both head models using either pure cortex segmentation only or a concentric three‐shell model, the dipole source was systematically dislocated in a more superior position. Data analysis by a second group with independently chosen EEG samples and identical individual head model resulted in deviations of >5.3 mm. Data analysis using independently selected spikes and independently segmented head models resulted in deviations 16.7 mm. Conclusions: In four cases of extratemporal epileptogenesis, the origin of interictal epileptiform discharges was localized to the suspected primary epileptogenic zone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EEG dipole modeling in complex partial epilepsy
Ebersole, J. S. (1991) · Brain Topography · doi:10.1007/bf01132768 · Cited by 132
Cited by
Epileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413
Monte Carlo simulation studies of EEG and MEG localization accuracy
Liu, A. K., Dale, A. M., & Belliveau, J. W. (2002) · Human Brain Mapping · doi:10.1002/hbm.10024 · Cited by 349
Barkley, G. L., & Baumgartner, C. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200305000-00002 · Cited by 202
“These latter models, however, provide more accurate solutions and can especially improve the accuracy of the solution for the EEG inverse problem in the temporal region (Fuchs et al., 1999; Hämäläinen and Sarvas, 1989; Herrendorf et al., 2000; Waberski et al., 1998, 2000).”
BackgroundPartial and generalized epilepsy with febrile seizures plus and a novel SCN1A mutation
Abou-Khalil, B., Ge, Q., Desai, R., Ryther, R., Bazyk, A., Bailey, R., Haines, J. L., Sutcliffe, J. S., & George, A. L. (2001) · Neurology · doi:10.1212/wnl.57.12.2265 · Cited by 200
128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision
Michel, C. M., Lantz, G., Spinelli, L., de Peralta, R. G., Landis, T., & Seeck, M. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200403000-00001 · Cited by 183
“realistic head models, EEG source localization in epilepsy is now possible with very high localizing precision (Herrendorf et al., 2000; Huppertz et al., 2001; Lantz et al., 2003a; Waberski et al., 2000).”
BackgroundElectromagnetic Inverse Solutions in Anatomically Constrained Spherical Head Models
Spinelli, L., Andino, S. G., Lantz, G., Seeck, M., & Michel, C. M. (2000) · Brain Topography · doi:10.1023/a:1026607118642 · Cited by 182
“While these latter methods have already been applied to clinical data by some authors (Roth et al. 1997; Ebersole et al. 1997; Fuchs et al. 1999; Herrendorf et al. 2000) still several issues have to be solved before they become a practical clinical tool.”
MethodLantz, G., Spinelli, L., Seeck, M., de Peralta Menendez, R. G., Sottas, C. C., & Michel, C. M. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200309000-00003 · Cited by 170
“One possibility to assess source propagation is the moving dipole model, although this concept is not entirely in line with the notion of propagation as sequential activation of different discrete regions (Herrendorf et al., 2000).”
BackgroundMethodEffect of EEG electrode number on epileptic source localization in pediatric patients
Sohrabpour, A., Lu, Y., Kankirawatana, P., Blount, J., Kim, H., & He, B. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.05.038 · Cited by 149
Dynamic imaging of seizure activity in pediatric epilepsy patients
Lu, Y., Yang, L., Worrell, G. A., Brinkmann, B., Nelson, C., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.04.021 · Cited by 32
“Studies have shown that more precise source localization results can be obtained in realistic-geometric head models compared to simple spherical head models (Herrendorf et al., 2000; Wang et al., 2010).”
BackgroundNoninvasive cortical imaging of epileptiform activities from interictal spikes in pediatric patients
Lai, Y., Zhang, X., van Drongelen, W., Korhman, M., Hecox, K., Ni, Y., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.026 · Cited by 22
“In another work (Herrendorf et al., 2000), by using the RG head model, the origin of interictal epileptiform discharges was localized to the primary epileptogenic zone in cases of extratemporal epileptogenesis.”
Method
Metadata
- Authors
- Herrendorf, G., Steinhoff, B. J., Kolle, R., Baudewig, J., Waberski, T. D., Buchner, H., & Paulus, W.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2000-12
- Volume
- 41
- Issue
- 1
- Pages
- 71-80
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2042038256
- Cited by
- 54
- References
- 1
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.