Effect of sleep stage on interictal high‐frequency oscillations recorded from depth macroelectrodes in patients with focal epilepsy
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Summary: Purpose: To investigate the effect of sleep stage on the properties of high‐frequency oscillations (HFOs) recorded from depth macroelectrodes in patients with focal epilepsy. Methods: Ten‐minute epochs of wakefulness (W), stage 1–2 non‐REM (N1‐N2), stage 3 non‐REM (N3) and REM sleep (R) were identified from stereo‐electroencephalography (SEEG) data recorded at 2 kHz in nine patients. Rates of spikes, ripples (>80 Hz), and fast ripples (>250 Hz) were calculated, as were HFO durations, degree of spike–HFO overlap, HFO rates inside and outside of spikes, and inside and outside of the seizure‐onset zone (SOZ). Results: Ripples were observed in nine patients and fast ripples in eight. Spike rate was highest in N1‐N2 in 5 of 9 patients, and in N3 in 4 of 9 patients, whereas ripple rate was highest in N1‐N2 in 4 of 9 patients, in N3 in 4 of 9 patients, and in W in 1 of 9 patients. Fast ripple rate was highest in N1‐N2 in 4 of 8 patients, and in N3 in 4 of 8 patients. HFO properties changed significantly with sleep stage, although the absolute effects were small. The difference in HFO rates inside and outside of the SOZ was highly significant (p < 0.000001) in all stages except for R and, for fast ripples, only marginally significant (p = 0.018) in W. Conclusions: Rates of HFOs recorded from depth macroelectrodes are highest in non‐REM sleep. HFO properties were similar in stages N1‐N2 and N3, suggesting that accurate sleep staging is not necessary. The spatial specificity of HFO, particularly fast ripples, was affected by sleep stage, suggesting that recordings excluding REM sleep and wakefulness provide a more reliable indicator of the SOZ.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2007) · Cited by 6,530
Bragin, A., Engel, J., Wilson, C. L., Fried, I., & Mathern, G. W. (1999) · Epilepsia · doi:10.1111/j.1528-1157.1999.tb02065.x · Cited by 745
Staba, R. J., Wilson, C. L., Bragin, A., Fried, I., & Engel, J. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.4.1743 · Cited by 666 · cited 3×
“…to be a signature of both normal and pathologic brain processes (Draguhn et al., 2000; Engel et al., 2003), whereas fast ripples have been identified only in epileptogenic tissue in both patients and animal models of epilepsy (Bragin et al., 1999a, 1999b; Staba et al., 2002; Engel et al., 2003).”
BackgroundMethodJacobs, J., LeVan, P., Chander, R., Hall, J., Dubeau, F., & Gotman, J. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01656.x · Cited by 634 · cited 8×
“…with quiescent EMG. High delta activity on intracranial EEG has been used as an indicator of slow-wave sleep in previous studies (Urrestarazu et al., 2007; Jacobs et al., 2008), and has been shown to be a hallmark of slow-wave sleep in intracranial recordings from the cat (Destexhe et al., 1999).”
BackgroundMethodSelf-citationDestexhe, A., Contreras, D., & Steriade, M. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-11-04595.1999 · Cited by 573 · cited 2×
“, 2008), and has been shown to be a hallmark of slow-wave sleep in intracranial recordings from the cat (Destexhe et al., 1999).”
BackgroundMethodHigh-frequency oscillations and seizure generation in neocortical epilepsy
Worrell, G. A., Parish, L., Cranstoun, S. D., Jonas, R., Baltuch, G., & Litt, B. (2004) · Brain · doi:10.1093/brain/awh149 · Cited by 539 · cited 2×
“…presence of highfrequency oscillations (HFOs) in the intracranial EEG (stereo-encephalography, SEEG) of patients with epilepsy, both in the ictal (Worrell et al., 2004; Jirsch et al., 2006) and interictal (Bragin et al., 1999a, 1999b, 2002; Staba et al., 2002, 2004; Urrestarazu et al., 2006;…”
BackgroundHigh-frequency oscillations during human focal seizures
Jirsch, J. D. (2006) · Brain · doi:10.1093/brain/awl085 · Cited by 533 · cited 3×
“Similar high-frequency events have also been reported using standard macroelectrodes (Jirsch et al., 2006; Urrestarazu et al., 2006, 2007), and oscillations up to 150 Hz have been recorded using foramen ovale electrodes (Clemens et al., 2007).”
BackgroundWorrell, G. A., Gardner, A. B., Stead, S. M., Hu, S., Goerss, S., Cascino, G. J., Meyer, F. B., Marsh, R., & Litt, B. (2008) · Brain · doi:10.1093/brain/awn006 · Cited by 458 · cited 4×
“In a recent study, Worrell et al. (2008) explicitly examined the relationship between HFOs recorded with microelectrodes and macroelectrodes by using both types of recording contact in the same patients.”
BackgroundMethodResultInfluentialInterictal high-frequency oscillations (100–500 Hz) in the intracerebral EEG of epileptic patients
Urrestarazu, E., Chander, R., Dubeau, F., & Gotman, J. (2007) · Brain · doi:10.1093/brain/awm149 · Cited by 421 · cited 10×
“, 2007) is highest in non–rapid eye movement (non-REM) sleep, and this information has been used in some studies to focus the analysis specifically on slow-wave sleep, since it is a relatively easy stage of non-REM sleep to detect (Urrestarazu et al., 2007; Jacobs et al., 2008; Worrell et al., 2008).”
BackgroundMethodSelf-citationTemporal coupling of parahippocampal ripples, sleep spindles and slow oscillations in humans
Clemens, Z., Molle, M., Eross, L., Barsi, P., Halasz, P., & Born, J. (2007) · Brain · doi:10.1093/brain/awm146 · Cited by 398 · cited 7×
“Previous work in both humans and animal models has demonstrated the usefulness and selectivity of HFO, particularly above 250 Hz, as a method of defining the epileptogenic zone (Bragin et al., 1999b; Staba et al., 2002; Engel et al., 2003; Urrestarazu et al., 2007; Worrell et al., 2008).”
BackgroundMethodResultInfluentialSammaritano, M., Gigli, G. L., & Gotman, J. (1991) · Neurology · doi:10.1212/wnl.41.2_part_1.290 · Cited by 351 · cited 1×
“It has been suggested previously that REM sleep provides more clinically reliable information than other stages by demonstrating more restricted epileptic foci (Sammaritano et al., 1991).”
BackgroundSelf-citationInterictal high‐frequency oscillations (80–500Hz) in the human epileptic brain: Entorhinal cortex
Bragin, A., Wilson, C. L., Staba, R. J., Reddick, M., Fried, I., & Engel, J. (2002) · Annals of Neurology · doi:10.1002/ana.10291 · Cited by 330 · cited 3×
“Microelectrodes consist of multiple microwires of approximately 40 lm diameter inserted through the middle of polyurethane multicontact SEEG probes (Bragin et al., 2002; Staba et al., 2007).”
BackgroundInfluentialHigh‐frequency oscillations recorded in human medial temporal lobe during sleep
Staba, R. J., Wilson, C. L., Bragin, A., Jhung, D., Fried, I., & Engel, J. (2004) · Annals of Neurology · doi:10.1002/ana.20164 · Cited by 326 · cited 11×
“Progress has been made in this direction using recordings from microwires (Staba et al., 2004) but, as discussed in the Introduction, conclusions drawn from microelectrode studies cannot be directly transferred to macroelectrode recordings because of the very different size of the sampled neuronal populations (Jirsch…”
BackgroundMethodResultInfluentialAdvances in Epileptology: XVIth Epilepsy International Symposium
Wasterlain, C. G. (1988) · Neurology · doi:10.1212/wnl.38.2.339-b · Cited by 313
High‐Frequency Intracerebral EEG Activity (100–500 Hz) Following Interictal Spikes
Urrestarazu, E., Jirsch, J. D., LeVan, P., & Hall, J. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00618.x · Cited by 156 · cited 3×
“Similar high-frequency events have also been reported using standard macroelectrodes (Jirsch et al., 2006; Urrestarazu et al., 2006, 2007), and oscillations up to 150 Hz have been recorded using foramen ovale electrodes (Clemens et al., 2007).”
BackgroundSelf-citationStaba, R. J., Frighetto, L., Behnke, E., Mathern, G. W., Fields, T. A., Bragin, A., Ogren, J. A., Fried, I., Wilson, C. L., & Engel, J. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01225.x · Cited by 155 · cited 1×
“Microelectrodes consist of multiple microwires of approximately 40 lm diameter inserted through the middle of polyurethane multicontact SEEG probes (Bragin et al., 2002; Staba et al., 2007).”
BackgroundRipple (˜200-Hz) Oscillations in Temporal Structures
Draguhn, A., Traub, R. D., Bibbig, A., & Schmitz, D. (2000) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200007000-00003 · Cited by 91 · cited 1×
“Ripples are considered to be a signature of both normal and pathologic brain processes (Draguhn et al., 2000; Engel et al., 2003), whereas fast ripples have been identified only in epileptogenic tissue in both patients and animal models of epilepsy (Bragin et al., 1999a, 1999b; Staba et al., 2002;…”
BackgroundEngel, J., Wilson, C. L., & Bragin, A. (2003) · Epilepsia · doi:10.1111/j.0013-9580.2003.12002.x · Cited by 76
(1999) · doi:10.1002/(sici)1098-1063(1999)9:2<137::aid-hipo5>3.0.co;2-0
Cited by
High‐frequency electroencephalographic oscillations correlate with outcome of epilepsy surgery
Jacobs, J., Zijlmans, M., Zelmann, R., Chatillon, C., Hall, J., Olivier, A., Dubeau, F., & Gotman, J. (2010) · Annals of Neurology · doi:10.1002/ana.21847 · Cited by 673
Self-citationHigh‐frequency oscillations as a new biomarker in epilepsy
Zijlmans, M., Jiruska, P., Zelmann, R., Leijten, F. S. S., Jefferys, J. G. R., & Gotman, J. (2012) · Annals of Neurology · doi:10.1002/ana.22548 · Cited by 524
Self-citation(2013) · Elsevier eBooks · doi:10.1016/c2010-0-65035-8 · Cited by 465
High-frequency oscillations (HFOs) in clinical epilepsy
Jacobs, J., Staba, R., Asano, E., Otsubo, H., Wu, J. Y., Zijlmans, M., Mohamed, I., Kahane, P., Dubeau, F., Navarro, V., et al. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.03.001 · Cited by 443
Self-citationHigh‐frequency oscillations: The state of clinical research
Frauscher, B., Bartolomei, F., Kobayashi, K., Cimbalnik, J., van ‘t Klooster, M. A., Rampp, S., Otsubo, H., Höller, Y., Wu, J. Y., Asano, E., et al. (2017) · Epilepsia · doi:10.1111/epi.13829 · Cited by 395
Self-citation
Metadata
- Authors
- Bagshaw, A. P., Jacobs, J., LeVan, P., Dubeau, F., & Gotman, J.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2009-04
- Volume
- 50
- Issue
- 4
- Pages
- 617-628
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2088531396
- Cited by
- 229
- References
- 19
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.