CoChat

Field and Laboratory Alcohol Detection With 2 Types of Transdermal Devices

Open access
Marques, Paul R., McKnight, A. Scott · 2009 · Alcoholism: Clinical and Experimental Research
Cited by 103

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Two types of transdermal electrochemical sensors that detect alcohol at the skin surface were evaluated. One, the AMS SCRAM™ device, is locked onto the ankle and is based on a fuel cell sensor; the other, a Giner WrisTAS™ device, worn on the wrist, is based on a proton exchange membrane. SCRAM is used by several court systems in the United States to monitor alcohol offenders, WrisTAS, a research prototype, is not commercially available. Methods: The 2 devices were worn concurrently by 22 paid research subjects (15 men, 7 women), for a combined total of 96 weeks. Subjects participated in both laboratory‐dosed drinking to a target of 0.08 g/dl blood alcohol concentration (BAC), and normal drinking on their own; all subjects were trained to use and carry a portable fuel‐cell breath tester for BAC determinations. Overall 271 drinking episodes with BAC ≥ 0.02 g/dl formed the signal for detection—60 from laboratory dosing, and 211 from self‐dosed drinking, with BAC ranging from 0.02 to 0.230 g/dl (mean 0.077 g/dl). Results: False negatives were defined as a transdermal alcohol concentration response equivalent <0.02 g/dl when BAC ≥ 0.02 g/dl. The overall true‐positive hit rate detected by WrisTAS was 24%. The low detection rate was due to erratic output and not recording during nearly 67% of all episodes; reportedly a chipset, not a sensor problem. SCRAM correctly detected 57% across all BAC events, with another 22% (total 79%) detected, but as <0.02 g/dl. When subjects dosed themselves to BAC ≥ 0.08 g/dl, SCRAM correctly detected 88% of these events. SCRAM devices lost accuracy over time likely due to water accumulation in the sensor housing. Neither unit had false‐positive problems when true BAC was <0.02 g/dl. Conclusions: Each device had peculiarities that reduced performance, but both types are able to detect alcohol at the skin surface. With product improvements, transdermal sensing may become a valuable way to monitor the alcohol consumption of those who should be abstaining.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1530-0277.2008.00887.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 103

Metadata

Authors
Marques, P. R., & McKnight, A. S.
Venue
Alcoholism: Clinical and Experimental Research
Publisher
Wiley
Published
2009-03-25
Volume
33
Issue
4
Pages
703-711
ISSN
  • 0145-6008 (ISSN-L)
  • 1530-0277
OpenAlex
W2158926281
Cited by
103
References
3
FWCI
2.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Field and Laboratory Alcohol Detection With 2 Types of Transdermal Devices. https://app.cochat.ai/papers/10.1111/j.1530-0277.2008.00887.x
The paper
Marques, P. R., & McKnight, A. S. (2009). Field and Laboratory Alcohol Detection With 2 Types of Transdermal Devices. Alcoholism: Clinical and Experimental Research. https://doi.org/10.1111/j.1530-0277.2008.00887.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.