Feasibility of Long‐Term Electrocardiographic Monitoring with an Implanted Device for Syncope Diagnosis
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Patients with infrequent recurrent syncope undiagnosed after extensive noninvasive and invasive testing pose a diagnostic and therapeutic dilemma. The purpose of this pilot study was to assess the feasibility of using an implanted, long‐term monitor as an aid to diagnosis in these patients. This was done using commercially available pacemakers with monitoring functions. Sixteen patients (eight males and eight femaiesj, aged 59.7 ± 17 years who had unexplained syncope despite a 12‐lead electrocardiogram, repeated Holter monitoring, exercise testing, echocardiography, an eJectro‐physioJogical study, and a tiJf test (n = 6), were entered into the study. Patients had experienced a mean of 3.3 ± 1 episodes of syncope in the 12 months prior to the study. All provided a history suggestive of Stokes‐Adams attacks and were referred for consideration of pacemaker implantation. Two patients had ischemic heart disease and one patient had a long QT interval. Patients had an Intermedics Nova II or Medtronic Quintech DPG pulse generator capable of recording sensed and paced events implanted with a single right ventricular lead. Syncope or presyncope occurred in ten patients (62%) 4.9 ± 4.2 months after pacemaker implantation. Bradycardia was detected in six patients and four patients had no arrhythmia. In addition to bradycardia, one patient also had tachycardia detected. Pacing therapy resulted in symptom relief in all six patients with syncope or presyncope due to bradycardia. Complications of pacemaker implantation (lead insulation failure) occurred in two patients. One of these patients subsequently had an infection of the generator pocket with associated systemic sepsis. Although the devices used in this study have serious limitations, the results suggest that continuous long‐term electrocardiographic monitoring can be useful in patients with recurrent syncope and a negative diagnostic work‐up. A smaller device with self‐contained electrodes designed for this purpose would be required for wider applicability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Prospective Evaluation and Follow-up of Patients with Syncope
Kapoor, W. N., Karpf, M., Wieand, S., Peterson, J. R., & Levey, G. S. (1983) · New England Journal of Medicine · doi:10.1056/nejm198307283090401 · Cited by 779
Evaluation and outcome of emergency room patients with transient loss of consciousness
Day, S. C., Cook, E. F., Funkenstein, H., & Goldman, L. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90913-5 · Cited by 587
Gulamhusein, S., Naccarelli, G. V., Ko, P. T., Prystowsky, E. N., Zipes, D. P., Barnett, H. J. M., Heger, J. J., & Klein, G. J. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90413-2 · Cited by 177
Self-citationFujimura, O., Yee, R., Klein, G. J., Sharma, A. D., & Boahene, K. A. (1989) · New England Journal of Medicine · doi:10.1056/nejm198912213212503 · Cited by 158
Self-citationDiagnostic and prognostic implicatioins of recurrences in patients with syncope
Kapoor, W. N., Peterson, J., Wieand, H. S., & Karpf, M. (1987) · The American Journal of Medicine · doi:10.1016/0002-9343(87)90901-6 · Cited by 126
Brown, A. P., Dawkins, K. D., & Davies, J. G. (1987) · Heart · doi:10.1136/hrt.58.3.251 · Cited by 96
Cited by
ACC/AHA guidelines for ambulatory electrocardiography
Crawford, M. H., Bernstein, S. J., Deedwania, P. C., DiMarco, J. P., Ferrick, K. J., Garson, A., Green, L. A., Greene, H. L., Silka, M. J., Stone, P. H., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00354-x · Cited by 309
The etiology of syncope in patients with negative tilt table and electrophysiological testing
Krahn, A. D., Klein, G. J., Norris, C., & Yee, R. (1995) · Circulation · doi:10.1161/01.cir.92.7.1819 · Cited by 215
Self-citationMenozzi, C., Brignole, M., Lolli, G., Bottoni, N., Oddone, D., Gianfranchi, L., & Gaggioli, G. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90985-l · Cited by 93
Implications of mechanism of bradycardia on response to pacing in patients with unexplained syncope
Sud, S., Klein, G. J., Skanes, A. C., Gula, L. J., Yee, R., & Krahn, A. D. (2007) · EP Europace · doi:10.1093/europace/eum020 · Cited by 66
Self-citationIncidence and predictors of syncope in paced patients with sick sinus syndrome
SGARBOSSA, E. B., PINSKI, S. L., JAEGER, F. J., TROHMAN, R. G., & MALONEY, J. D. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb03021.x · Cited by 55
Metadata
- Authors
- MURDOCK, C. J., KLEIN, G. J., YEE, R., LEITCH, J. W., TEO, W. S., & NORRIS, C.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1990-11
- Volume
- 13
- Issue
- 11
- Pages
- 1374-1378
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2061008133
- Cited by
- 28
- References
- 6
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Feasibility of Long‐Term Electrocardiographic Monitoring with an Implanted Device for Syncope Diagnosis. https://app.cochat.ai/papers/10.1111/j.1540-8159.1990.tb04011.x
- The paper
- MURDOCK, C. J., KLEIN, G. J., YEE, R., LEITCH, J. W., TEO, W. S., & NORRIS, C. (1990). Feasibility of Long‐Term Electrocardiographic Monitoring with an Implanted Device for Syncope Diagnosis. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1990.tb04011.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.