CoChat

Five‐Years Experience with Intravascular Lead Extraction

SMITH, HEIDI J., FEARNOT, NEAL E., BYRD, CHARLES L., WILKOFF, BRUCE L., LOVE, CHARLES J., SELLERS, T. DUNCAN, for the U.S. LEAD EXTRACTION DATABASE · 1994 · Pacing and Clinical Electrophysiology
Cited by 278

The DOI matches its Crossref record.

Abstract

From December 1988 to April 1994, the extraction of 2,195 intravascular pacing leads from 1.299 patients was attempted at 193 centers. Indications were: infection (54%, including 10% septicemia), pacemaker reoperation with removal of nonfunctional or incompatible leads (40%), and other causes (6%). Extraction was attempted via the implant vein using locking stylets and dilator sheaths, via the femoral vein using snares, retrieval baskets, and sheaths, or via both approaches. Leads had been implanted for 0.2 months to 24 years (mean 56 months). At the conclusion of the intravascular procedure, 86.8% of the leads were completely removed, 7.5% were partially removed, and 5.7% were not removed. For physicians performing their first case, 12% of leads were not removed; for physicians who had performed more than 10 cases, only 2% of leads were not removed. Of the 189 leads where extraction attempts had previously failed, 75.1% were completely removed, 14.8% were partially removed, and 10.1% were not removed. Scar tissue increased in severity with implant duration, was a complicating factor, and was the main cause of failure to remove leads. Use of the femoral approach increased with implant duration (5% of leads implanted 12 months or less, 11% of leads 13 months to 3 years, 20% of leads 4–7 years, and 31 % of leads 8–24 years), primarily because of increasingly abundant scarring and prior lead damage. Fatal and near fatal complications occurred in 2.5%. including 8 (0.6%) deaths (3 hemopericardium/tamponade, 1 hemothorax, 3 pulmonary embolus, 1 stroke). With experienced operators, appropriate precautions, and appropriate patient selection, modern techniques allow the successful extraction of up to nearly 98% of intravascular leads with a relatively low incidence of complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1994.tb03792.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
SMITH, H. J., FEARNOT, N. E., BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., & DATABASE, F. T. U. S. L. E.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1994-11
Volume
17
Issue
11
Pages
2016-2020
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2161052336
Cited by
278
References
0
FWCI
5.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.