Five‐Years Experience with Intravascular Lead Extraction
The DOI matches its Crossref record.
Abstract
From December 1988 to April 1994, the extraction of 2,195 intravascular pacing leads from 1.299 patients was attempted at 193 centers. Indications were: infection (54%, including 10% septicemia), pacemaker reoperation with removal of nonfunctional or incompatible leads (40%), and other causes (6%). Extraction was attempted via the implant vein using locking stylets and dilator sheaths, via the femoral vein using snares, retrieval baskets, and sheaths, or via both approaches. Leads had been implanted for 0.2 months to 24 years (mean 56 months). At the conclusion of the intravascular procedure, 86.8% of the leads were completely removed, 7.5% were partially removed, and 5.7% were not removed. For physicians performing their first case, 12% of leads were not removed; for physicians who had performed more than 10 cases, only 2% of leads were not removed. Of the 189 leads where extraction attempts had previously failed, 75.1% were completely removed, 14.8% were partially removed, and 10.1% were not removed. Scar tissue increased in severity with implant duration, was a complicating factor, and was the main cause of failure to remove leads. Use of the femoral approach increased with implant duration (5% of leads implanted 12 months or less, 11% of leads 13 months to 3 years, 20% of leads 4–7 years, and 31 % of leads 8–24 years), primarily because of increasingly abundant scarring and prior lead damage. Fatal and near fatal complications occurred in 2.5%. including 8 (0.6%) deaths (3 hemopericardium/tamponade, 1 hemothorax, 3 pulmonary embolus, 1 stroke). With experienced operators, appropriate precautions, and appropriate patient selection, modern techniques allow the successful extraction of up to nearly 98% of intravascular leads with a relatively low incidence of complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wilkoff, B. L., Love, C. J., Byrd, C. L., Bongiorni, M. G., Carrillo, R. G., Crossley, G. H., Epstein, L. M., Friedman, R. A., Kennergren, C. E. H., Mitkowski, P., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.05.020 · Cited by 1,024
Self-citationWilkoff, B. L., Byrd, C. L., Love, C. J., Hayes, D. L., Sellers, T. D., Schaerf, R., Parsonnet, V., Epstein, L. M., Sorrentino, R. A., & Reiser, C. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00074-1 · Cited by 438
Self-citationNORTH AMERICAN SOCIETY OF PACING AND ELECTROPHYSIOLOGY LEAD EXTRACTION CONFERENCE FACULTY, LOVE, C. J., WILKOFF, B. L., BYRD, C. L., BELOTT, P. H., BRINKER, J. A., FEARNOT, N. E., FRIEDMAN, R. A., FURMAN, S., GOODE, L. B., et al. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb00845.x · Cited by 353
Self-citationClinical Study of the Laser Sheath for Lead Extraction: The Total Experience in the United States
BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., & REISER, C. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.t01-1-00804.x · Cited by 308
Self-citationIntravascular Extraction of Problematic or Infected Permanent Pacemaker Leads: 1994–1996
BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., TURK, K. T., REEVES, R., YOUNG, R., CREVEY, B., KUTALEK, S. P., FREEDMAN, R., et al. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00628.x · Cited by 279
Self-citationHauser, R. G., Katsiyiannis, W. T., Gornick, C. C., Almquist, A. K., & Kallinen, L. M. (2010) · Europace · doi:10.1093/europace/eup375 · Cited by 264
“These device-assisted procedures employ technologies that free leads from encapsulating fibrous tissue which binds them to major veins and cardiac structures and other implanted leads.(1) – 6 Although infection has been the most common indication for device-assisted lead extraction, lead malfunction, the removal of ab…”
BackgroundMethodSoft Bioelectronics Based on Nanomaterials
Cho, K. W., Sunwoo, S.-H., Hong, Y. J., Koo, J. H., Kim, J. H., Baik, S., Hyeon, T., & Kim, D.-H. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00531 · Cited by 244
Jones, S. O., Eckart, R. E., Albert, C. M., & Epstein, L. M. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.01.009 · Cited by 216
Authors (EHRA Task Force Members), Deharo, J. C., Bongiorni, M. G., Rozkovec, A., Bracke, F., Defaye, P., Fernandez-Lozano, I., Golzio, P. G., Hansky, B., Kennergren, C., et al. (2012) · Europace · doi:10.1093/europace/eur338 · Cited by 210
Self-citationA single-centre experience of over one thousand lead extractions
Kennergren, C., Bjurman, C., Wiklund, R., & Gabel, J. (2009) · Europace · doi:10.1093/europace/eup054 · Cited by 205
Local symptoms at the site of pacemaker implantation indicate latent systemic infection
Klug, D., Wallet, F., Lacroix, D., Marquié, C., Kouakam, C., Kacet, S., & Courcol, R. (2004) · Heart · doi:10.1136/hrt.2003.010595 · Cited by 195
Extraction of Transvenous Pacing and ICD Leads
SMITH, M. C., & LOVE, C. J. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01079.x · Cited by 167
Self-citationGuidelines for Managing Pacemaker and Implantable Defibrillator Advisories
Kramer, D. B., & Maisel, W. H. (2011) · Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy · doi:10.1016/b978-1-4377-1616-0.00034-5 · Cited by 8
Metadata
- Authors
- SMITH, H. J., FEARNOT, N. E., BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., & DATABASE, F. T. U. S. L. E.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1994-11
- Volume
- 17
- Issue
- 11
- Pages
- 2016-2020
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2161052336
- Cited by
- 278
- References
- 0
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.