Potential Cost Savings by Telemedicine‐Assisted Long‐Term Care of Implantable Cardioverter Defibrillator Recipients
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Home monitoring (HM) of cardioverter defibrillators (ICD) with its automated wireless remote data access, may decrease the rate of patient visits. This study examined the potential cost savings for the long‐term care of ICD assisted by HM. A French database including 502 patients from 6 university hospitals was used. Costs of conventional follow‐up (FU) of ICD were calculated without, and compared with the expected cost of FU with HM. Calculations included number of visits, including physician's fees, electrocardiograms, and specific ICD surveillance, and transportation costs. The mean distance between home and institutions performing follow‐ups was 69 ± 57 km. For each visit, a mean overall cost of $215 was calculated, including $121 for transportation and $94 for medical services. HM may obviate up to 2 visits per year. Over the 5 years of expected life of the device, the decrease in costs for FU visits was estimated at $2,149. With an additional cost of $1,200 for the HM system, saving began after a mean FU of 33.5 months. The time to onset of cost saving by HM ranged between 17.4 months for patients living >150 km from the medical facility to 52.2 months for those living <50 km away. It is concluded that the HM may considerably reduce the overall costs of ICD FU by saving on transportation cost, particularly when the distance between home and medical facility is >100 km.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489
de Lusignan, S., Wells, S., Johnson, P., Meredith, K., & Leatham, E. (2001) · European Journal of Heart Failure · doi:10.1016/s1388-9842(01)00190-8 · Cited by 195
Cited by
Slotwiner, D., Varma, N., Akar, J. G., Annas, G., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 532
Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.013 · Cited by 364
Landolina, M., Perego, G. B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Borghi, G., Zanaboni, P., Valsecchi, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.088971 · Cited by 344
Telerehabilitation for Stroke Survivors: Systematic Review and Meta-Analysis
Tchero, H., Tabue Teguo, M., Lannuzel, A., & Rusch, E. (2018) · Journal of Medical Internet Research · doi:10.2196/10867 · Cited by 277
Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Europace · doi:10.1093/europace/eun122 · Cited by 231
Raatikainen, M. J. P., Uusimaa, P., van Ginneken, M. M. E., Janssen, J. P. G., & Linnaluoto, M. (2008) · Europace · doi:10.1093/europace/eun203 · Cited by 189
“Fauchier et al.(13) calculated recently that remote monitoring reduced the overall cost of ICD follow-up when the distance between home and the device clinic was .”
Klersy, C., De Silvestri, A., Gabutti, G., Raisaro, A., Curti, M., Regoli, F., & Auricchio, A. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfq232 · Cited by 150
“Also a sizeable reduction in the number of follow-up visits for device monitoring, and associated travelling costs for HF patients treated with implantable cardioverterdefibrillator and/or cardiac resynchronization therapy devices, has already been reported.(10,11) In these two observational studies, the authors repor…”
BackgroundMARZEGALLI, M., LUNATI, M., LANDOLINA, M., PEREGO, G. B., RICCI, R. P., GUENZATI, G., SCHIRRU, M., BELVITO, C., BRAMBILLA, R., MASELLA, C., et al. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01175.x · Cited by 134
Telemedicine and cardiac implants: what is the benefit?
Varma, N., & Ricci, R. P. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs388 · Cited by 102
“Thus, remote monitoring permitted a saving of E524 per patient per year (41% of standard follow-up cost) in Finland(67) but $2149 per patient over 5 years in France.(68) Even”
BackgroundInfluentialDubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47
(2008) · Cited by 28
A Systematic Review of Economic Evaluations of Pacemaker Telemonitoring Systems
López-Villegas, A., Catalán-Matamoros, D., Martín-Saborido, C., Villegas-Tripiana, I., & Robles-Musso, E. (2016) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2015.06.020 · Cited by 19
Costa, P. D., Reis, A. H., & Rodrigues, P. P. (2013) · Telemedicine and e-Health · doi:10.1089/tmj.2012.0064 · Cited by 16
“Also, Fauchier et al. 24 observed cost reductions for the patient and reduced displacements with a break-even point at 26 months.”
Monitoring capabilities of cardiac rhythm management devices
Andrikopoulos, G., Tzeis, S., Theodorakis, G., & Vardas, P. (2010) · Europace · doi:10.1093/europace/eup317 · Cited by 5
Metadata
- Authors
- FAUCHIER, L., SADOUL, N., KOUAKAM, C., BRIAND, F., CHAUVIN, M., BABUTY, D., & CLEMENTY, J.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2005-01
- Volume
- 28
- Issue
- s1
- Pages
- S255-9
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2049994699
- Cited by
- 124
- References
- 2
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.