Pulmonary Vein Vestibule Ablation for the Control of Atrial Fibrillation in Patients with Impaired Left Ventricular Function
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Introduction: Congestive heart failure (CHF) and atrial fibrillation (AF) are frequently linked, and when associated produce additive deleterious effects. In this prospective study, the effects of catheter ablation for AF in patients with impaired left ventricular (LV) function are presented. Methods: Baseline data and clinical outcome have been prospectively collected in 105 consecutive patients who underwent pulmonary vein ablation for the control of AF. We evaluated 40 patients affected by LV dysfunction with ejection fraction (EF) <40% and compared them to the remaining 65 patients with normal ventricular function in terms of changes in LV function, maintenance of sinus rhythm, and quality of life during follow‐up. Results: After a mean follow‐up of 14 ± 2 months, 87% of patients with impaired LV function and 92% of patients with normal ventricular function were in sinus rhythm, with or without antiarrhythmic therapy (P = NS). A significant improvement in LVEF and fractional shortening was documented in patients with CHF (33 ± 2% vs 47 ± 3%, and 19 ± 4% vs 30 ± 3%, P < 0.01 for both comparisons). Evaluation of exercise capacity and quality of life documented better improvements in patients with CHF compared to patients without CHF. Conclusions: Catheter ablation in patients with LV dysfunction is feasible, not associated with higher procedural complications, and provides a significant improvement in LV performance, symptoms, and quality of life during follow‐up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McHorney, C. A., Ware, J. E., Rachel Lu, J. F., & Sherbourne, C. D. (1994) · Medical Care · doi:10.1097/00005650-199401000-00004 · Cited by 4,458
Pappone, C., Rosanio, S., Augello, G., Gallus, G., Vicedomini, G., Mazzone, P., Gulletta, S., Gugliotta, F., Pappone, A., Santinelli, V., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00577-1 · Cited by 781
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Wann, L. S., Curtis, A. B., January, C. T., Ellenbogen, K. A., Lowe, J. E., Estes, N. A. M., Page, R. L., Ezekowitz, M. D., Slotwiner, D. J., Jackman, W. M., et al. (2011) · Circulation · doi:10.1161/cir.0b013e3181fa3cf4 · Cited by 1,336
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citationDi Biase, L., Mohanty, P., Mohanty, S., Santangeli, P., Trivedi, C., Lakkireddy, D., Reddy, M., Jais, P., Themistoclakis, S., Dello Russo, A., et al. (2016) · Circulation · doi:10.1161/circulationaha.115.019406 · Cited by 867
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.08.001 · Cited by 707
Self-citationAtrial Fibrillation and Heart Failure: Treatment Considerations for a Dual Epidemic
Anter, E., Jessup, M., & Callans, D. J. (2009) · Circulation · doi:10.1161/circulationaha.108.821306 · Cited by 678
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux275 · Cited by 509
Self-citationHunter, R. J., Berriman, T. J., Diab, I., Kamdar, R., Richmond, L., Baker, V., Goromonzi, F., Sawhney, V., Duncan, E., Page, S. P., et al. (2014) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000806 · Cited by 505
Jones, D. G., Haldar, S. K., Hussain, W., Sharma, R., Francis, D. P., Rahman-Haley, S. L., McDonagh, T. A., Underwood, S. R., Markides, V., & Wong, T. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.069 · Cited by 481
Wann, L. S., Curtis, A. B., Ellenbogen, K. A., Estes, N. A. M., Ezekowitz, M. D., Jackman, W. M., January, C. T., Lowe, J. E., Page, R. L., Slotwiner, D. J., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.01.032 · Cited by 395
MacDonald, M. R., Connelly, D. T., Hawkins, N. M., Steedman, T., Payne, J., Shaw, M., Denvir, M., Bhagra, S., Small, S., Martin, W., et al. (2011) · Heart · doi:10.1136/hrt.2010.207340 · Cited by 350
Complications of Catheter Ablation of Atrial Fibrillation: A Systematic Review
Gupta, A., Perera, T., Ganesan, A., Sullivan, T., Lau, D. H., Roberts-Thomson, K. C., Brooks, A. G., & Sanders, P. (2013) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000768 · Cited by 317
Wann, L. S., Curtis, A. B., January, C. T., Ellenbogen, K. A., Lowe, J. E., Estes, N. A. M., Page, R. L., Ezekowitz, M. D., Slotwiner, D. J., Jackman, W. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.10.001 · Cited by 230
Anselmino, M., Matta, M., D’Ascenzo, F., Bunch, T. J., Schilling, R. J., Hunter, R. J., Pappone, C., Neumann, T., Noelker, G., Fiala, M., et al. (2014) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001938 · Cited by 174
Dagres, N., Varounis, C., Gaspar, T., Piorkowski, C., Eitel, C., Iliodromitis, E. K., Lekakis, J. P., Flevari, P., Simeonidou, E., Rallidis, L. S., et al. (2011) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2011.07.009 · Cited by 133
Ganesan, A. N., Nandal, S., Lüker, J., Pathak, R. K., Mahajan, R., Twomey, D., Lau, D. H., & Sanders, P. (2015) · Heart Lung and Circulation · doi:10.1016/j.hlc.2014.09.012 · Cited by 73
“Study quality was limited in that the majority of studies were non-randomised, including single centre case series [7–20], with four randomised control trials [21–24].”
BackgroundMethodCalvo, N., Bisbal, F., Guiu, E., Ramos, P., Nadal, M., Tolosana, J. M., Arbelo, E., Berruezo, A., Sitges, M., Brugada, J., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.07.017 · Cited by 64
Metadata
- Authors
- TONDO, C., MANTICA, M., RUSSO, G., AVELLA, A., DE LUCA, L., PAPPALARDO, A., FAGUNDES, R. L., PICCHIO, E., LAURENZI, F., PIAZZA, V., & BISCEGLIA, I.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2006-09
- Volume
- 29
- Issue
- 9
- Pages
- 962-970
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2007214362
- Cited by
- 118
- References
- 2
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.