Remote, Wireless, Ambulatory Monitoring of Implantable Pacemakers, Cardioverter Defibrillators, and Cardiac Resynchronization Therapy Systems: Analysis of a Worldwide Database
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Study Objective: To describe the daily routine application of a new telemonitoring system in a large population of cardiac device recipients. Methods: Data transmitted daily and automatically by a remote, wireless Home Monitoring™ system (HM) were analyzed. The average time gained in the detection of events using HM versus standard practice and the impact of HM on physician workload were examined. The mean interval between device interrogations was used to compare the rates of follow‐up visits versus that recommended in guidelines. Results: 3,004,763 transmissions were made by 11,624 recipients of pacemakers (n = 4,631), defibrillators (ICD; n = 6,548), and combined ICD + cardiac resynchronization therapy (CRT‐D) systems (n = 445) worldwide. The duration of monitoring/patient ranged from 1 to 49 months, representing 10,057 years. The vast majority (86%) of events were disease‐related. The mean interval between last follow‐up and occurrence of events notified by HM was 26 days, representing a putative temporal gain of 154 and 64 days in patients usually followed at 6‐ and 3‐month intervals, respectively. The mean numbers of events per patient per month reported to the caregivers for the overall population was 0.6. On average, 47.6% of the patients were event‐free. The mean interval between follow‐up visits in patients with pacemakers, single‐chamber ICDs, dual chamber ICDs, and CRT‐D systems were 5.9 ± 2.1, 3.6 ± 3.3, 3.3 ± 3.5, and 1.9 ± 2.9 months, respectively. Conclusions: This broad clinical application of a new monitoring system strongly supports its capability to improve the care of cardiac device recipients, enhance their safety, and optimize the allocation of health resources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,266
Aaronson, K. D., Schwartz, J. S., Chen, T.-M., Wong, K.-L., Goin, J. E., & Mancini, D. M. (1997) · Circulation · doi:10.1161/01.cir.95.12.2660 · Cited by 1,188
Predictors of mortality and morbidity in patients with chronic heart failure
Pocock, S. J., Wang, D., Pfeffer, M. A., Yusuf, S., McMurray, J. J. V., Swedberg, K. B., Östergren, J., Michelson, E. L., Pieper, K. S., & Granger, C. B. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi555 · Cited by 973
Cleland, J. G. F., Louis, A. A., Rigby, A. S., Janssens, U., & Balk, A. H. M. M. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.01.050 · Cited by 700
Page, R. L., Wilkinson, W. E., Clair, W. K., McCarthy, E. A., & Pritchett, E. L. (1994) · Circulation · doi:10.1161/01.cir.89.1.224 · Cited by 627
Hindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H. (2005) · Circulation · doi:10.1161/circulationaha.104.518837 · Cited by 506
Riegel, B., Carlson, B., Kopp, Z., LePetri, B., Glaser, D., & Unger, A. (2002) · Archives of Internal Medicine · doi:10.1001/archinte.162.6.705 · Cited by 473
Goldberg, L. R., Piette, J. D., Walsh, M. N., Frank, T. A., Jaski, B. E., Smith, A. L., Rodriguez, R., Mancini, D. M., Hopton, L. A., Orav, E. J., et al. (2003) · American Heart Journal · doi:10.1016/s0002-8703(03)00393-4 · Cited by 366
Prevention of atrial fibrillation after cardioversion: results of the PAFAC trial
FETSCH, T. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.04.015 · Cited by 334
Management of Atrial Fibrillation
Wood, A. J. J., & Pritchett, E. L. C. (1992) · New England Journal of Medicine · doi:10.1056/nejm199205073261906 · Cited by 325
Cited by
Ambient backscatter: wireless communication out of thin air
Liu, V., Parks, A., Talla, V., Gollakota, S., Wetherall, D., & Smith, J. R. (2013) · Proceedings of the ACM SIGCOMM 2013 conference on SIGCOMM · doi:10.1145/2486001.2486015 · Cited by 1,060
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
Ambient backscatter: wireless communication out of thin air
Liu, V., Parks, A., Talla, V., Gollakota, S., Wetherall, D., & Smith, J. R. (2013) · ACM SIGCOMM Computer Communication Review · doi:10.1145/2534169.2486015 · Cited by 652
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Varma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594
Chung, M. K., Patton, K. K., Lau, C.-P., Dal Forno, A. R. J., Al-Khatib, S. M., Arora, V., Birgersdotter-Green, U. M., Cha, Y.-M., Chung, E. H., Cronin, E. M., et al. (2023) · Heart Rhythm · doi:10.1016/j.hrthm.2023.03.1538 · Cited by 548
Slotwiner, D., Varma, N., Akar, J. G., Annas, G., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 532
A Meta-Analysis of Remote Monitoring of Heart Failure Patients
Klersy, C., De Silvestri, A., Gabutti, G., Regoli, F., & Auricchio, A. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.017 · Cited by 380
A randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial)
Mabo, P., Victor, F., Bazin, P., Ahres, S., Babuty, D., Da Costa, A., Binet, D., & Daubert, J.-C. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr419 · Cited by 347
Landolina, M., Perego, G. B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Borghi, G., Zanaboni, P., Valsecchi, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.088971 · Cited by 344
Guedon-Moreau, L., Lacroix, D., Sadoul, N., Clementy, J., Kouakam, C., Hermida, J.-S., Aliot, E., Boursier, M., Bizeau, O., Kacet, S., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs425 · Cited by 312
Gorenek, B., Bax, J., Boriani, G., Chen, S.-A., Dagres, N., Glotzer, T. V., Healey, J. S., Israel, C. W., Kudaiberdieva, G., Levin, L.-Å., et al. (2017) · EP Europace · doi:10.1093/europace/eux163 · Cited by 247
Clinical Benefits of Remote Versus Transtelephonic Monitoring of Implanted Pacemakers
Crossley, G. H., Chen, J., Choucair, W., Cohen, T. J., Gohn, D. C., Johnson, W. B., Kennedy, E. E., Mongeon, L. R., Serwer, G. A., Qiao, H., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.001 · Cited by 202
Raatikainen, M. J. P., Uusimaa, P., van Ginneken, M. M. E., Janssen, J. P. G., & Linnaluoto, M. (2008) · Europace · doi:10.1093/europace/eun203 · Cited by 189
Shanmugam, N., Boerdlein, A., Proff, J., Ong, P., Valencia, O., Maier, S. K. G., Bauer, W. R., Paul, V., & Sack, S. (2012) · Europace · doi:10.1093/europace/eur293 · Cited by 182
Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators
Burri, H., & Senouf, D. (2009) · Europace · doi:10.1093/europace/eup110 · Cited by 180
“Remote monitoring may be particularly useful in patients with CRT, as they are most likely to have transmissions of medically related events.(12) A number of different randomized trials are currently underway to assess the utility of monitoring lung fluid overload in patients with heart failure (Table 3).”
BackgroundDubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Europace · doi:10.1093/europace/eur303 · Cited by 179
Ricci, R. P., Morichelli, L., & Santini, M. (2008) · Europace · doi:10.1093/europace/eum289 · Cited by 178
“0 ICD implant indication (%) Primary 10 (34) Secondary 19 (66) Structural heart disease (%) Hypertension 32 (36) 2 (7) Hyschemic 16 (18) 15 (52) Valvular 6 (7) 0 (0) Cardiomyopathy 2 (2) 9 (31) None 32 (36) 2 (7) Prior atrial fibrillation (%) 29 (33) 5 (26) Prior myocardial infarction (%) 5 (6) 9 (31) Prior myocardial…”
Ricci, R. P., Morichelli, L., & Santini, M. (2008) · Europace · doi:10.1093/europace/eun303 · Cited by 169
“Automatic alerts are sent to the clinical staff in case of trigger events.(11)”
BackgroundMethodHome Telemonitoring in Patients With Chronic Heart Failure
Schmidt, S., Schuchert, A., Krieg, T., & Oeff, M. (2010) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2010.0131 · Cited by 48
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47
Remote monitoring of implantable devices: should we continue to ignore it?
Bertini, M., Marcantoni, L., Toselli, T., & Ferrari, R. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.09.033 · Cited by 28
“Already in 2007 Lazarus demonstrated the usefulness of RM to early detect (more than 64 days before a quarterly scheduled visit) inappropriate shocks [6].”
BackgroundDrak-Hernández, Y., Toquero-Ramos, J., Fernández, J. M., Pérez-Pereira, E., Castro-Urda, V., & Fernández-Lozano, I. (2013) · Revista Española de Cardiología · doi:10.1016/j.recesp.2013.06.012 · Cited by 14
“El tiempo medio transcurrido desde el implante del HI al diagnóstico de un evento significativo es considerable y significativamente menor para los pacientes con MD (56 [0-650] dı́as) que para los pacientes con SC (260 [5-947] dı́as [p < 0,001]).”
BackgroundMonitoring capabilities of cardiac rhythm management devices
Andrikopoulos, G., Tzeis, S., Theodorakis, G., & Vardas, P. (2010) · Europace · doi:10.1093/europace/eup317 · Cited by 5
Metadata
- Authors
- LAZARUS, A.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2007-01
- Volume
- 30
- Issue
- s1
- Pages
- S2-S12
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2167547881
- Cited by
- 228
- References
- 25
- FWCI
- 12.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.