Asymptomatic Atrial Fibrillation in Pacemaker Recipients: Incidence, Progression, and Determinants Based on the Atrial High Rate Trial
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background: The epidemiology and clinical implications of asymptomatic atrial tachyarrhythmias (AT) including both atrial fibrillation and flutter in pacemaker recipients with and without arrhythmia history are not well understood. The Atrial High Rate Episodes (A‐HIRATE) in Pacemaker Patients Trial was designed to identify and compare the incidence of AT in patients with and without previously diagnosed AT and a standard indication for dual chamber pacing, and to provide useful diagnostic information for clinical management. Methods: Four hundred twenty‐seven patients were implanted with a pacemaker (Kappa 7‐900, Medtronic, Inc., Minneapolis, MN, USA) capable of detecting and storing multiple atrial high rate episodes (AHRE) and followed for 2 years. Group I included 331 patients without prior history of AT and Group II included 96 patients with prior AT history. Results: Pacemaker diagnostics appropriately detected 93% of reviewed AHRE. The rate of occurrence of first AHRE was significantly higher (P < 0.0001) in Group II patients, as was average AHRE burden. The rate of first AHRE occurrence was 88.6% for patients in Group II and 53.8% in Group I at 24 months post‐implant. The rate of AHRE occurrence was similar in both groups after the first month post‐implant. The majority of stored AHRE were asymptomatic; symptoms did not correspond to an actual AHRE in most patients. Conclusions: The incidence of AT in pacemaker recipients is high. Most device‐detected AHRE are asymptomatic. Prior history of AT is associated with higher arrhythmia burden. AHRE diagnostics have a high positive predictive value for identifying AT events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impact of Atrial Fibrillation on the Risk of Death: The Framingham Heart Study
Benjamin, E. J., Wolf, P. A., D’Agostino, R. B., Silbershatz, H., Kannel, W. B., & Levy, D. (1998) · Circulation · doi:10.1161/01.cir.98.10.946 · Cited by 4,575
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Page, R. L., Wilkinson, W. E., Clair, W. K., McCarthy, E. A., & Pritchett, E. L. (1994) · Circulation · doi:10.1161/01.cir.89.1.224 · Cited by 627
Kühlkamp, V., Schirdewan, A., Stangl, K., Homberg, M., Ploch, M., & Beck, O. A. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00693-8 · Cited by 256
Temporal patterns of paroxysmal atrial fibrillation following DDDR pacemaker implantation
Gillis, A. M., & Rose, M. S. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00792-x · Cited by 55
Cited by
Slotwiner, D., Varma, N., Akar, J. G., Annas, G., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 532
Minimizing Ventricular Pacing to Reduce Atrial Fibrillation in Sinus-Node Disease
Sweeney, M. O., Bank, A. J., Nsah, E., Koullick, M., Zeng, Q. C., Hettrick, D., Sheldon, T., & Lamas, G. A. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071880 · Cited by 520
Self-citationPrevention of Atrial Fibrillation by Renin-Angiotensin System Inhibition
Schneider, M. P., Hua, T. A., Böhm, M., Wachtell, K., Kjeldsen, S. E., & Schmieder, R. E. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.01.043 · Cited by 417
Themistoclakis, S., Corrado, A., Marchlinski, F. E., Jais, P., Zado, E., Rossillo, A., Di Biase, L., Schweikert, R. A., Saliba, W. I., Horton, R., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.039 · Cited by 276
Reiffel, J. A., Verma, A., Kowey, P. R., Halperin, J. L., Gersh, B. J., Wachter, R., Pouliot, E., Ziegler, P. D., & for the REVEAL AF Investigators (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.3180 · Cited by 265
Self-citation
Metadata
- Authors
- ORLOV, M. V., GHALI, J. K., ARAGHI‐NIKNAM, M., SHERFESEE, L., SAHR, D., HETTRICK, D. A., & for the Atrial High Rate Trial Investigators
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2007-03
- Volume
- 30
- Issue
- 3
- Pages
- 404-411
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2057346167
- Cited by
- 119
- References
- 5
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Asymptomatic Atrial Fibrillation in Pacemaker Recipients: Incidence, Progression, and Determinants Based on the Atrial High Rate Trial. https://app.cochat.ai/papers/10.1111/j.1540-8159.2007.00682.x
- The paper
- ORLOV, M. V., GHALI, J. K., ARAGHI‐NIKNAM, M., SHERFESEE, L., SAHR, D., HETTRICK, D. A., & for the Atrial High Rate Trial Investigators. (2007). Asymptomatic Atrial Fibrillation in Pacemaker Recipients: Incidence, Progression, and Determinants Based on the Atrial High Rate Trial. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2007.00682.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.