CoChat

How Revealing Are Insertable Loop Recorders in Pediatrics?

FRANGINI, PATRICIA A., CECCHIN, FRANK, JORDAO, LIGIA, MARTUSCELLO, MARIA, ALEXANDER, MARK E., TRIEDMAN, JOHN K., WALSH, EDWARD P., BERUL, CHARLES I. · 2008 · Pacing and Clinical Electrophysiology
Cited by 57

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Introduction: An insertable loop recorder (ILR) in patients with infrequent syncope or palpitations may be useful to decide management strategies, including clinical observation, medical therapy, pacemaker, or implantable cardioverter defibrillator (ICD). We sought to determine the diagnostic utility of the Reveal® ILR (Medtronic, Inc., Minneapolis, MN, USA) in pediatric patients. Methods: Retrospective review of clinical data, indications, findings, and therapeutic decision in 27 consecutive patients who underwent ILR implantation from 1998–2007. Results: The median age was 14.8 years (2–25 years). Indications were syncope in 24 patients and recurrent palpitations in three. Overall, eight patients had structural heart disease (six congenital heart disease, one hypertrophic cardiomyopathy, one Kawasaki), five had previous documented ventricular arrhythmias with negative evaluation including electrophysiology study, and three patients had QT prolongation. Tilt testing was performed in 10 patients, of which five had neurocardiogenic syncope but recurrent episodes despite medical therapy. After median three months (1–20 months), 17 patients presented with symptoms and the ILR memory was analyzed in 16 (no episode stored in one due to full device memory), showing asystole or transient atrioventricular (AV) block (2), sinus bradycardia (6), or normal sinus rhythm (8). Among asymptomatic patients, 3/10 had intermittent AV block or long pauses, automatically detected and stored by the ILR. In 19 of 20 patients, ILR was diagnostic (95%) and five subsequently underwent pacemaker implantation, while seven patients remained asymptomatic without ILR events. Notably, no life‐threatening events were detected. The ILR was explanted in 22 patients after a median of 22 months, two due to pocket infection, 12 for battery depletion and eight after clear documentation of nonmalignant arrhythmia. Conclusions: The ILR in pediatrics is a useful adjunct to other diagnostic studies. Patient selection is critical as the ILR should not be utilized for malignant arrhythmias. A diagnosis is attained in the majority of symptomatic patients, predominantly bradyarrhythmias including pauses and intermittent AV block.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2008.00995.x

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 57

Metadata

Authors
FRANGINI, P. A., CECCHIN, F., JORDAO, L., MARTUSCELLO, M., ALEXANDER, M. E., TRIEDMAN, J. K., WALSH, E. P., & BERUL, C. I.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2008-02-28
Volume
31
Issue
3
Pages
338-343
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2139840424
Cited by
57
References
6
FWCI
2.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: How Revealing Are Insertable Loop Recorders in Pediatrics? https://app.cochat.ai/papers/10.1111/j.1540-8159.2008.00995.x
The paper
FRANGINI, P. A., CECCHIN, F., JORDAO, L., MARTUSCELLO, M., ALEXANDER, M. E., TRIEDMAN, J. K., WALSH, E. P., & BERUL, C. I. (2008). How Revealing Are Insertable Loop Recorders in Pediatrics? Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2008.00995.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.