CoChat

Repolarization Spatial‐Time Current Abnormalities in Patients with Coronary Heart Disease

OGATA, KUNIOMI, KANDORI, AKIHIKO, WATANABE, YASUSHI, SUZUKI, AKIHIRO, TANAKA, KIMIO, OKA, YUJI, TAKAKI, HIROSHI, KANZAKI, HIDEAKI, NAKATANI, SATOSHI, MIYATAKE, KUNIO, WATANABE, SHIGEYUKI, YAMAGUCHI, IWAO, MIYASHITA, TSUYOSHI, KAMAKURA, SHIRO · 2009 · Pacing and Clinical Electrophysiology
Cited by 16

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background:Magnetocardiography (MCG) is a new technique for visualizing a current distribution in the myocardium. In recent years, current distribution parameters (CDPs) have been developed based on the distribution. The CDPs reflect spatial‐time current abnormalities in patients with coronary heart disease (CHD). However, the criteria and scoring method of the abnormalities using CDPs are still controversial. Method:We measured MCG signals for 101 normal controls and 56 CHD patients (single‐, double‐, and triple‐vessel diseases) using a MCG system. The CDPs (maximum current vector [MCV], total current vector [TCV], current integral map, and current rotation) during ventricular repolarization were analyzed. To evaluate the CDPs that are effective in distinguishing between normal controls and CHD patients, the areas under the receiver operating characteristic curve (A z) are calculated. Furthermore, the total scores (“0” to “4”) of four CDPs with high A z values are also calculated. Results:MCV and TCV angles at the T‐wave peak had the highest A z value. Furthermore, TCV angular differences between the ST‐T segment also had high A z values. Using the four CDPs, the averaged total score for patients with triple‐vessel disease was the highest (“2.67”) compared to the other groups (normal controls: 0.53). Furthermore, based on the assumption that subjects with a total score over “1” were suspected of having CHD, sensitivity and specificity were 85.7% and 74.3%, respectively. Conclusion:We concluded that the score and criteria using MCV and TCV during repolarization in CHD patients can reflect lesion areas and time changes of electrical activation dispersion due to ischemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2009.02313.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 16

Metadata

Authors
OGATA, K., KANDORI, A., WATANABE, Y., SUZUKI, A., TANAKA, K., OKA, Y., TAKAKI, H., KANZAKI, H., NAKATANI, S., MIYATAKE, K., WATANABE, S., YAMAGUCHI, I., MIYASHITA, T., & KAMAKURA, S.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2009-03-23
Volume
32
Issue
4
Pages
516-524
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2033531108
Cited by
16
References
3
FWCI
0.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Repolarization Spatial‐Time Current Abnormalities in Patients with Coronary Heart Disease. https://app.cochat.ai/papers/10.1111/j.1540-8159.2009.02313.x
The paper
OGATA, K., KANDORI, A., WATANABE, Y., SUZUKI, A., TANAKA, K., OKA, Y., TAKAKI, H., KANZAKI, H., NAKATANI, S., MIYATAKE, K., WATANABE, S., YAMAGUCHI, I., MIYASHITA, T., & KAMAKURA, S. (2009). Repolarization Spatial‐Time Current Abnormalities in Patients with Coronary Heart Disease. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2009.02313.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.