The Efficacy of Inducibility and Circumferential Ablation with Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation

CHANG, SHIH‐LIN, TAI, CHING‐TAI, LIN, YENN‐JIANG, WONGCHAROEN, WANWARANG, LO, LI‐WEI, TUAN, TA‐CHUAN, UDYAVAR, AMEYA R., CHANG, SHENG‐HSIUNG, TSAO, HSUAN‐MING, HSIEH, MING‐HSIUNG, HU, YU‐FENG, CHEN, YI‐JEN, CHEN, SHIH‐ANN · 2007 · Journal of Cardiovascular Electrophysiology

Abstract

Introduction: Some conflicting results of the efficacy of the inducibility test used in the catheter ablation of atrial fibrillation (AF) have been reported. The aim of this study was to investigate the inducibility and efficacy of circumferential ablation with pulmonary vein isolation (PVI) in patients with paroxysmal AF and its relationship to the atrial substrate. Methods and Results: This study consisted of 88 patients with paroxysmal AF who underwent catheter ablation. Electroanatomic mapping using a NavX system was performed and the biatrial voltage was obtained during sinus rhythm. After successful circumferential ablation with PVI, an inducibility test was performed to determine the requirement for creating left atrial (LA) ablation line. After procedure, patients with inducible AF had a higher recurrence rate than did those with noninducibility of AF (55% vs 18%, P = 0.02). The patients with inducible AF after the PVI had a lower biatrial voltage than did those with negative inducibility. The patients with inducible AF after the final procedure who had a recurrence had a lower LA voltage (1.3 ± 0.4 vs 1.8 ± 0.4 mV, P = 0.02) and longer LA total activation time (99 ± 18 vs 88 ± 13 msec, P = 0.02) than did those with noninducible AF and no recurrence. None of the patients had occurrence of LA flutter during the follow‐up. Conclusion: After a single procedure of circumferential ablation with PVI and noninducibility, 82% patients did not have recurrence of AF. The inducibility of AF was related to the recurrence of AF. The atrial substrate affected the outcome of the inducibility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2007.00823.x

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 296

Metadata

Authors
CHANG, S., TAI, C., LIN, Y., WONGCHAROEN, W., LO, L., TUAN, T., UDYAVAR, A. R., CHANG, S., TSAO, H., HSIEH, M., HU, Y., CHEN, Y., & CHEN, S.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2007-05-03
Volume
18
Issue
6
Pages
607-611
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2001751311
Cited by
296
References
24
FWCI
15.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Efficacy of Inducibility and Circumferential Ablation with Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2007.00823.x
The paper
CHANG, S., TAI, C., LIN, Y., WONGCHAROEN, W., LO, L., TUAN, T., UDYAVAR, A. R., CHANG, S., TSAO, H., HSIEH, M., HU, Y., CHEN, Y., & CHEN, S. (2007). The Efficacy of Inducibility and Circumferential Ablation with Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2007.00823.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.