The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
The Efficacy of Inducibility and Circumferential Ablation with Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation
Abstract
Introduction: Some conflicting results of the efficacy of the inducibility test used in the catheter ablation of atrial fibrillation (AF) have been reported. The aim of this study was to investigate the inducibility and efficacy of circumferential ablation with pulmonary vein isolation (PVI) in patients with paroxysmal AF and its relationship to the atrial substrate. Methods and Results: This study consisted of 88 patients with paroxysmal AF who underwent catheter ablation. Electroanatomic mapping using a NavX system was performed and the biatrial voltage was obtained during sinus rhythm. After successful circumferential ablation with PVI, an inducibility test was performed to determine the requirement for creating left atrial (LA) ablation line. After procedure, patients with inducible AF had a higher recurrence rate than did those with noninducibility of AF (55% vs 18%, P = 0.02). The patients with inducible AF after the PVI had a lower biatrial voltage than did those with negative inducibility. The patients with inducible AF after the final procedure who had a recurrence had a lower LA voltage (1.3 ± 0.4 vs 1.8 ± 0.4 mV, P = 0.02) and longer LA total activation time (99 ± 18 vs 88 ± 13 msec, P = 0.02) than did those with noninducible AF and no recurrence. None of the patients had occurrence of LA flutter during the follow‐up. Conclusion: After a single procedure of circumferential ablation with PVI and noninducibility, 82% patients did not have recurrence of AF. The inducibility of AF was related to the recurrence of AF. The atrial substrate affected the outcome of the inducibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Benjamin, E. J. (1994) · JAMA · doi:10.1001/jama.1994.03510350050036 · Cited by 2,613
Obesity and the risk of new-onset atrial fibrillation
Wang, T. J. (2004) · JAMA · doi:10.1001/jama.292.20.2471 · Cited by 1,427
Ouyang, F., Bänsch, D., Ernst, S., Schaumann, A., Hachiya, H., Chen, M., Chun, J., Falk, P., Khanedani, A., Antz, M., et al. (2004) · Circulation · doi:10.1161/01.cir.0000144459.37455.ee · Cited by 757
HAÏSSAGUERRE, M., HOCINI, M., SANDERS, P., SACHER, F., ROTTER, M., TAKAHASHI, Y., ROSTOCK, T., HSU, L., BORDACHAR, P., REUTER, S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00308.x · Cited by 755
Catheter Ablation of Paroxysmal Atrial Fibrillation Initiated by Non–Pulmonary Vein Ectopy
Lin, W.-S., Tai, C.-T., Hsieh, M.-H., Tsai, C.-F., Lin, Y.-K., Tsao, H.-M., Huang, J.-L., Yu, W.-C., Yang, S.-P., Ding, Y.-A., et al. (2003) · Circulation · doi:10.1161/01.cir.0000074206.52056.2d · Cited by 752
Self-citationTechnique and Results of Linear Ablation at the Mitral Isthmus
Jaïs, P., Hocini, M., Hsu, L.-F., Sanders, P., Scavee, C., Weerasooriya, R., Macle, L., Raybaud, F., Garrigue, S., Shah, D. C., et al. (2004) · Circulation · doi:10.1161/01.cir.0000146917.75041.58 · Cited by 751
Sanders, P., Morton, J. B., Davidson, N. C., Spence, S. J., Vohra, J. K., Sparks, P. B., & Kalman, J. M. (2003) · Circulation · doi:10.1161/01.cir.0000090688.49283.67 · Cited by 622
Pre-existent left atrial scarring in patients undergoing pulmonary vein antrum isolation
Verma, A., Wazni, O. M., Marrouche, N. F., Martin, D. O., Kilicaslan, F., Minor, S., Schweikert, R. A., Saliba, W., Cummings, J., Burkhardt, J. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.035 · Cited by 595
Tsai, C.-F., Tai, C.-T., Hsieh, M.-H., Lin, W.-S., Yu, W.-C., Ueng, K.-C., Ding, Y.-A., Chang, M.-S., & Chen, S.-A. (2000) · Circulation · doi:10.1161/01.cir.102.1.67 · Cited by 549
Self-citationElectrophysiologic and electroanatomic changes in the human atrium associated with age
Kistler, P. M., Sanders, P., Fynn, S. P., Stevenson, I. H., Spence, S. J., Vohra, J. K., Sparks, P. B., & Kalman, J. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.044 · Cited by 476
Long‐Term Safety and Efficacy of Circumferential Ablation with Pulmonary Vein Isolation
CHEEMA, A., DONG, J., DALAL, D., VASAMREDDY, C. R., MARINE, J. E., HENRIKSON, C. A., SPRAGG, D., CHENG, A., NAZARIAN, S., SINHA, S., et al. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00569.x · Cited by 453
Mapping and ablation of left atrial flutters
Jaïs, P., Shah, D. C., Haïssaguerre, M., Hocini, M., Peng, J. T., Takahashi, A., Garrigue, S., Le Métayer, P., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.101.25.2928 · Cited by 380
Chugh, A., Oral, H., Lemola, K., Hall, B., Cheung, P., Good, E., Tamirisa, K., Han, J., Bogun, F., Pelosi, F., et al. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.01.027 · Cited by 338
Mechanisms of organized left atrial tachycardias occurring after pulmonary vein isolation
Gerstenfeld, E. P., Callans, D. J., Dixit, S., Russo, A. M., Nayak, H., Lin, D., Pulliam, W., Siddique, S., & Marchlinski, F. E. (2004) · Circulation · doi:10.1161/01.cir.0000141369.50476.d3 · Cited by 300
Oral, H., Chugh, A., Lemola, K., Cheung, P., Hall, B., Good, E., Han, J., Tamirisa, K., Bogun, F., Pelosi, F., et al. (2004) · Circulation · doi:10.1161/01.cir.0000146786.87037.26 · Cited by 243
Long-term single procedure efficacy of catheter ablation of atrial fibrillation
Cheema, A., Vasamreddy, C. R., Dalal, D., Marine, J. E., Dong, J., Henrikson, C. A., SPRAGG, D. D., Cheng, A., Nazarian, S., Sinha, S. K., et al. (2006) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-006-9005-9 · Cited by 133
Long-term evaluation of atrial fibrillation ablation guided by noninducibility
Jaı̈s, P., Hocini, M., Sanders, P., Hsu, L., Takahashi, Y., Rotter, M., Rostock, T., Sacher, F., Clémenty, J., & Haı̈ssaguerre, M. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2005.11.012 · Cited by 125
Shah, D. C., Sunthorn, H., Burri, H., Gentil-Baron, P., Pruvot, E. J., Schläpfer, J., & FROMER, M. A. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00413.x · Cited by 121
Hocini, M., Sanders, P., Jaïs, P., Hsu, L., Weerasooriya, R., Scavée, C., Takahashi, Y., Rotter, M., Raybaud, F., Macle, L., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi096 · Cited by 109
Atrial Fibrillation: A Perspective
Wyse, D. G., & Gersh, B. J. (2004) · Circulation · doi:10.1161/01.cir.0000132611.01101.dc · Cited by 98
Essebag, V., Baldessin, F., Reynolds, M. R., McClennen, S., Shah, J. S., Kwaku, K. F., ZIMETBAUM, P. J., & Josephson, M. E. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi507 · Cited by 96
Richter, B., Gwechenberger, M., Peter Filzmoser, A., Marx, M., Lercher, P., & Gössinger, H. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl307 · Cited by 75
A New Nonfluoroscopic Navigation System to Guide Pulmonary Vein Isolation
Tondo, C., Mantica, M., Russo, G., Karapatsoudi, E., Lucchina, A., NIGRO, F., WILD, M., MOLINARO, C., & Bavila, R. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00047.x · Cited by 36
Kılıçaslan, F., Verma, A., Yamaji, H., Marrouche, N. F., Wazni, O. M., Cummings, J. E., Hao, S. C., Andrews, M. W., Beheiry, S., Abdul‐Karim, A., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.11.047 · Cited by 23
Cited by
HAÏSSAGUERRE, M., HOCINI, M., SANDERS, P., SACHER, F., ROTTER, M., TAKAHASHI, Y., ROSTOCK, T., HSU, L., BORDACHAR, P., REUTER, S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00308.x · Cited by 755
HAÏSSAGUERRE, M., SANDERS, P., HOCINI, M., TAKAHASHI, Y., ROTTER, M., SACHER, F., ROSTOCK, T., HSU, L., BORDACHAR, P., REUTER, S., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00307.x · Cited by 675
Reversal of Left Ventricular Dysfunction Following Ablation of Atrial Fibrillation
GENTLESK, P. J., SAUER, W. H., GERSTENFELD, E. P., LIN, D., DIXIT, S., PA‐C, E. Z., CALLANS, D., & MARCHLINSKI, F. E. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00653.x · Cited by 276
Arya, A., Hindricks, G., Sommer, P., Huo, Y., Bollmann, A., Gaspar, T., Bode, K., Husser, D., Kottkamp, H., & Piorkowski, C. (2010) · Europace · doi:10.1093/europace/eup331 · Cited by 158
“It seems that other endpoints rather than completion of predefined lesions and/or a stepwise approach to the catheter ablation beyond the predefined lesions might be necessary in this subgroup of patients.(13,14,24,25) Further studies are needed to clarify this issue.”
BackgroundProarrhythmia of circumferential left atrial lesions for management of atrial fibrillation
DAOUD, E. G., WEISS, R., AUGOSTINI, R., HUMMEL, J. D., KALBFLEISCH, S. J., VAN DEREN, J. M., DAWSON, G., & BOWMAN, K. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00312.x · Cited by 59
Metadata
- Authors
- CHANG, S., TAI, C., LIN, Y., WONGCHAROEN, W., LO, L., TUAN, T., UDYAVAR, A. R., CHANG, S., TSAO, H., HSIEH, M., HU, Y., CHEN, Y., & CHEN, S.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2007-05-03
- Volume
- 18
- Issue
- 6
- Pages
- 607-611
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2001751311
- Cited by
- 296
- References
- 24
- FWCI
- 15.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.