Complications of Catheter Ablation for Atrial Fibrillation: Incidence and Predictors

SPRAGG, DAVID D., DALAL, DARSHAN, CHEEMA, AAMIR, SCHERR, DANIEL, CHILUKURI, KARUNA, CHENG, ALAN, HENRIKSON, CHARLES A., MARINE, JOSEPH E., BERGER, RONALD D., DONG, JUN, CALKINS, HUGH · 2008 · Journal of Cardiovascular Electrophysiology

Abstract

Introduction: Pulmonary vein (PV) isolation by catheter ablation is an increasingly used strategy to treat atrial fibrillation (AF). Complication rates from AF ablation reported in different case series vary widely. We conducted a retrospective analysis of 641 consecutive ablation procedures to assess complication rates, temporal trends, and clinical predictors of adverse outcomes. Methods: All patients (n = 517) undergoing catheter ablation for AF at Johns Hopkins Hospital between February, 2001 and June, 2007 were prospectively enrolled in a database. Data from 641 consecutive procedures were analyzed and complications considered if they occurred within 30 days of ablation. Major complications were defined as those that required intervention, resulted in long‐term disability, or prolonged hospitalization. Results: Thirty‐two major complications occurred in 641 procedures (5%). Among the patients with major complications, seven had cerebrovascular accident (CVA), eight had tamponade, one had PV occlusion with hemoptysis, and 11 had vascular injury requiring surgical repair and/or transfusion. No periprocedural deaths occurred, and no instances of esophageal injury were seen. Complication rates were higher during the first 100 cases (9.0%) than during the subsequent 541 (4.3%). Major adverse clinical events were associated with age > 70 years (P = 0.007; odds ratio 3.7, 95% confidence interval 1.4–9.6) and female gender (P = 0.014; odds ratio 3.0, 95% confidence interval 1.3–7.2). No other clinical or procedural predictors of complication were identified. Conclusions: Complication rates from AF ablation remain significant, despite improved techniques and increased awareness of procedural risks. Both advanced age and female gender predict major adverse events, suggesting careful consideration of the risk/benefit profile in these patients prior to ablation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2008.01181.x

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 287

Metadata

Authors
SPRAGG, D. D., DALAL, D., CHEEMA, A., SCHERR, D., CHILUKURI, K., CHENG, A., HENRIKSON, C. A., MARINE, J. E., BERGER, R. D., DONG, J., & CALKINS, H.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2008-06
Volume
19
Issue
6
Pages
627-631
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2004884130
Cited by
287
References
18
FWCI
17.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Complications of Catheter Ablation for Atrial Fibrillation: Incidence and Predictors. https://app.cochat.ai/papers/10.1111/j.1540-8167.2008.01181.x
The paper
SPRAGG, D. D., DALAL, D., CHEEMA, A., SCHERR, D., CHILUKURI, K., CHENG, A., HENRIKSON, C. A., MARINE, J. E., BERGER, R. D., DONG, J., & CALKINS, H. (2008). Complications of Catheter Ablation for Atrial Fibrillation: Incidence and Predictors. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2008.01181.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.