Negative Temperature Coefficient Resistance (NTCR) Ceramic Thermistors: An Industrial Perspective
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Monitoring and control of temperature is of paramount importance in every part of our daily life. Temperature sensors are ubiquitous not only in domestic and industrial activities but also in laboratory and medical procedures. An assortment of temperature sensors is commercially available for such purposes. They range from metallic thermocouples to resistive temperature detectors and semiconductive ceramics, showing a negative temperature coefficient of resistance (NTCR). NTCR ceramic sensors occupy a respected market position, because they afford the best sensitivity and accuracy at the lowest price. Despite the enormous commercial success of NTCR thermistors, this area of advanced functional ceramics has not been recently reviewed. Nearly 100 years elapsed between the first report of NTCR behavior and the fabrication of NTCR devices. The manufacture of the first NTCR ceramic thermistors was problematic, as often the devices suffered from poor stability and nonreproducibility. Before NTCR ceramics could be seriously considered for mass production of thermistors, it was necessary to devote a large amount of R&D effort to study the nature of their semiconductivity and understand the influence of impurities/dopants and heat treatments on their electrical characteristics, particularly in their time dependence resistivity (aging). Simultaneously, from a technological viewpoint it was important to develop methods enabling reliable and permanent electrical contacts, and design suitable housing for ceramics, in order to preserve their electrical properties under conditions of variable oxygen partial pressure and humidity. These topics are reviewed in this article from an industrial perspective. Examples of common applications of NTCR thermistors and future challenges are also outlined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theory of the Role of Covalence in the Perovskite-Type Manganites[La, M(II)]MnO3
Goodenough, J. B. (1955) · Physical Review · doi:10.1103/physrev.100.564 · Cited by 4,498
Electronic Conduction of Magnetite (Fe3O4) and its Transition Point at Low Temperatures
Verwey, E. J. W. (1939) · Nature · doi:10.1038/144327b0 · Cited by 1,755
An interpretation of the magnetic properties of the perovskite-type mixed crystals La1−xSrxCoO3−λ
Goodenough, J. B. (1958) · Journal of Physics and Chemistry of Solids · doi:10.1016/0022-3697(58)90107-0 · Cited by 1,395
Electronic conductivity and transition point of magnetite (“Fe3O4”)
Verwey, E. J. W., & Haayman, P. W. (1941) · Physica · doi:10.1016/s0031-8914(41)80005-6 · Cited by 942
Verwey, E. J. W., & Heilmann, E. L. (1947) · The Journal of Chemical Physics · doi:10.1063/1.1746464 · Cited by 880
Verwey, E. J., Haayman, P. W., & Romeijn, F. C. (1947) · The Journal of Chemical Physics · doi:10.1063/1.1746466 · Cited by 713
Goodenough, J. B., & Loeb, A. L. (1955) · Physical Review · doi:10.1103/physrev.98.391 · Cited by 706
Lorenzelli, V. (1989) · Materials Chemistry and Physics · doi:10.1016/0254-0584(89)90128-4 · Cited by 513
Electronic properties of transition-metal oxides—I
Dunitz, J. D., & Orgel, L. E. (1957) · Journal of Physics and Chemistry of Solids · doi:10.1016/0022-3697(57)90043-4 · Cited by 467
Electronic properties of transition-metal oxides-II
Dunitz, J. D., & Orgel, L. E. (1957) · Journal of Physics and Chemistry of Solids · doi:10.1016/0022-3697(57)90035-5 · Cited by 440
Cited by
Advanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2019) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,300
Electronic Muscles and Skins: A Review of Soft Sensors and Actuators
Chen, D., & Pei, Q. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00019 · Cited by 506
Stretchable Active Matrix Temperature Sensor Array of Polyaniline Nanofibers for Electronic Skin
Hong, S. Y., Lee, Y. H., Park, H., Jin, S. W., Jeong, Y. R., Yun, J., You, I., Zi, G., & Ha, J. S. (2016) · Advanced Materials · doi:10.1002/adma.201504659 · Cited by 454
Sensitive Wearable Temperature Sensor with Seamless Monolithic Integration
Shin, J., Jeong, B., Kim, J., Nam, V. B., Yoon, Y., Jung, J., Hong, S., Lee, H., Eom, H., Yeo, J., et al. (2020) · Advanced Materials · doi:10.1002/adma.201905527 · Cited by 449
Stretchable Graphene Thermistor with Tunable Thermal Index
Yan, C., Wang, J., & Lee, P. S. (2015) · ACS Nano · doi:10.1021/nn507441c · Cited by 359
“Among the several types of temperature sensors, the ceramic-based thermistor is advantageous in terms of fabrication cost, sensitivity, and response speed.(31) Transition metal oxides in bulk or thin film form are the most commonly used materials in thermistors;(32) 34 however, the lacking of mechanical flexibility li…”
BackgroundMethodInfluentialWang, B., Thukral, A., Xie, Z., Liu, L., Zhang, X., Huang, W., Yu, X., Yu, C., Marks, T. J., & Facchetti, A. (2020) · Nature Communications · doi:10.1038/s41467-020-16268-8 · Cited by 338
Physical sensors for skin‐inspired electronics
Li, S., Zhang, Y., Wang, Y., Xia, K., Yin, Z., Wang, H., Zhang, M., Liang, X., Lu, H., Zhu, M., et al. (2020) · InfoMat · doi:10.1002/inf2.12060 · Cited by 245
Hanft, D., Exner, J., Schubert, M., Stöcker, T., Fuierer, P. A., & Moos, R. (2015) · doi:10.4416/jcst2015-00018 · Cited by 239
Advanced carbon materials for flexible and wearable sensors
Jian, M., Wang, C., Wang, Q., Wang, H., Xia, K., Yin, Z., Zhang, M., Liang, X., & Zhang, Y. (2017) · Science China Materials · doi:10.1007/s40843-017-9077-x · Cited by 223
Highly Stretchable and Transparent Thermistor Based on Self-Healing Double Network Hydrogel
Wu, J., Han, S., Yang, T., Li, Z., Wu, Z., Gui, X., Tao, K., Miao, J., Norford, L. K., Liu, C., et al. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b03524 · Cited by 210
Wu, J., Wu, Z., Wei, Y., Ding, H., Huang, W., Gui, X., Shi, W., Shen, Y., Tao, K., & Xie, X. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c04359 · Cited by 210
A carbon nanotube based NTC thermistor using additive print manufacturing processes
Turkani, V. S., Maddipatla, D., Narakathu, B. B., Bazuin, B. J., & Atashbar, M. Z. (2018) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2018.05.042 · Cited by 145
Self-powered graphene thermistor
Bendi, R., Bhavanasi, V., Parida, K., Nguyen, V. C., Sumboja, A., Tsukagoshi, K., & Lee, P. S. (2016) · Nano Energy · doi:10.1016/j.nanoen.2016.06.014 · Cited by 30
Metadata
- Authors
- Feteira, A.
- Venue
- Journal of the American Ceramic Society
- Publisher
- Wiley
- Published
- 2009-05
- Volume
- 92
- Issue
- 5
- Pages
- 967-983
- ISSN
- 0002-7820 (ISSN-L)
- 1551-2916
- OpenAlex
- W2099027000
- Cited by
- 711
- References
- 21
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.