Evaluation of soft tissue around single‐tooth implant crowns: the pink esthetic score
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Aim: In this study, the reproducibility of a newly developed pink esthetic score (PES) for evaluating soft tissue around single‐tooth implant crowns was assessed. The effect of observer specialization was another point of interest. Material and methods: Twenty observers (five prosthodontists, five oral surgeons, five orthodontists and five dental students) were given photographs of 30 single‐tooth implant crowns. Seven variables were evaluated vs. a natural reference tooth: mesial papilla, distal papilla, soft‐tissue level, soft‐tissue contour, alveolar process deficiency, soft‐tissue color and texture. Using a 0‐1‐2 scoring system, 0 being the lowest, 2 being the highest value, the maximum achievable PES was 14. Each observer was requested to make two assessments at an interval of 4 weeks. At the second assessment, the photographs were scored in the reverse order. Results: The mean PES of evaluations at the first assessment (n=600) was 9.46 (±3.81 SD), and 9.24 (±3.8 SD) at the second one. The difference between these two means was not significant statistically (P=0.6379). Implant‐related mean PES for single‐tooth implants varied from 2.28 to 13.8, with standard deviations between 0.46 and 3.51. Very poor and very esthetic restorations showed the smallest standard deviations. The mean total PES was 10.6 for the prosthodontists, 9.2 for the oral surgeons, 9.9 for the dental students and 7.6 for the orthodontists. Conclusions: The PES reproducibly evaluates peri‐implant soft tissue around single‐tooth implants. Thus, an objective outcome of different surgical or prosthodontic protocols can be assessed. Orthodontists were clearly more critical than the other observers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patient selection and preparation
Lekholm, U. (1985) · Medical Entomology and Zoology · Cited by 1,173
Criteria for success of osseointegrated endosseous implants
Smith, D. E., & Zarb, G. A. (1989) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(89)90081-4 · Cited by 966
Comparing the Perception of Dentists and Lay People to Altered Dental Esthetics
KOKICH, V. O., ASUMAN KIYAK, H., & SHAPIRO, P. A. (1999) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/j.1708-8240.1999.tb00414.x · Cited by 844
Regeneration of gingival papillae after single-implant treatment.
Jemt, T. (1997) · PubMed · Cited by 581
A 5-year multicenter study on implant-supported single crown restorations.
Scheller, H., Urgell, J. P., Kultje, C., Ij, K., Goldberg, P. V., Stevenson‐Moore, P., Alonso, J. M., Schaller, M., Corriá, R. M., Engquist, B., et al. (1998) · PubMed · Cited by 226
(1986) · PubMed
Cited by
A systematic review of the 5‐year survival and complication rates of implant‐supported single crowns
Jung, R. E., Pjetursson, B. E., Glauser, R., Zembic, A., Zwahlen, M., & Lang, N. P. (2008) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01453.x · Cited by 1,063
Buser, D., Sennerby, L., & De Bruyn, H. (2017) · Periodontology 2000 · doi:10.1111/prd.12185 · Cited by 792
Belser, U. C., Grütter, L., Vailati, F., Bornstein, M. M., Weber, H., & Buser, D. (2009) · Journal of Periodontology · doi:10.1902/jop.2009.080435 · Cited by 738
Success Criteria in Implant Dentistry: A Systematic Review
Papaspyridakos, P., Chen, C.-J., Singh, M., Weber, H.-P., & Gallucci, G. O. (2012) · Journal of Dental Research · doi:10.1177/0022034511431252 · Cited by 625
Buser, D., Chappuis, V., Belser, U. C., & Chen, S. (2017) · Periodontology 2000 · doi:10.1111/prd.12170 · Cited by 479
Sailer, I., Philipp, A., Zembic, A., Pjetursson, B. E., Hämmerle, C. H. F., & Zwahlen, M. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01787.x · Cited by 368
Tavelli, L., Barootchi, S., Avila‐Ortiz, G., Urban, I. A., Giannobile, W. V., & Wang, H. (2021) · Journal of Periodontology · doi:10.1002/jper.19-0716 · Cited by 336
Den Hartog, L., Huddleston Slater, J. J. R., Vissink, A., Meijer, H. J. A., & Raghoebar, G. M. (2008) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2008.01330.x · Cited by 300
Duong, H., Roccuzzo, A., Stähli, A., Salvi, G. E., Lang, N. P., & Sculean, A. (2022) · Periodontology 2000 · doi:10.1111/prd.12419 · Cited by 283
Cosyn, J., Eghbali, A., De Bruyn, H., Collys, K., Cleymaet, R., & De Rouck, T. (2011) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2011.01748.x · Cited by 240
“The Pink Esthetic Score (PES) by Fürhauser et al. (2005) was used to evaluate the aesthetic outcome of the periimplant soft tissues.”
MethodBuser, D., Halbritter, S., Hart, C., Bornstein, M. M., Grütter, L., Chappuis, V., & Belser, U. C. (2009) · Journal of Periodontology · doi:10.1902/jop.2009.080360 · Cited by 231
Immediate Implant Placement Postextraction Without Flap Elevation
Chen, S. T., Darby, I. B., Reynolds, E. C., & Clement, J. G. (2009) · Journal of Periodontology · doi:10.1902/jop.2009.080243 · Cited by 207
van Velzen, F. J. J., Ofec, R., Schulten, E. A. J. M., & ten Bruggenkate, C. M. (2015) · Clinical Oral Implants Research · doi:10.1111/clr.12499 · Cited by 197
The Effect of Keratinized Mucosa Width on Peri-implant Health: A Systematic Review
Gobbato, L., Avila-Ortiz, G., Sohrabi, K., Wang, C.-W., & Karimbux, N. (2013) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.3244 · Cited by 188
Cosyn, J., Hooghe, N., & De Bruyn, H. (2012) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2012.01888.x · Cited by 186
“In 2005, an objective rating system was introduced for the aesthetic evaluation of peri-implant tissues (Fürhauser et al. 2005) around single implants and two studies could be identified using this method (Cosyn et al.”
MethodMorton, D., Chen, S., Martin, W., Levine, R., & Buser, D. (2014) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.2013.g3 · Cited by 184
“The factors associated with midfacial recession for immediate implant placement are (1) thin facial bone plate, (2) lack of intact facial bone plate, (3) facial malposition of the implant, and (4) thin soft tissue biotype.”
BackgroundCritical soft‐tissue dimensions with dental implants and treatment concepts
Thoma, D. S., Mühlemann, S., & Jung, R. E. (2014) · Periodontology 2000 · doi:10.1111/prd.12045 · Cited by 171
Zembic, A., Kim, S., Zwahlen, M., & Kelly, J. R. (2014) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.2014suppl.g2.2 · Cited by 166
Chen, J., Cai, M., Yang, J., Aldhohrah, T., & Wang, Y. (2019) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2019.05.013 · Cited by 166
Lang, N. P., Zitzmann, N. U., & on behalf of Working Group 3 of the VIII European Workshop on Periodontology (2012) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2011.01842.x · Cited by 140
Tonetti, M. S., Sanz, M., Avila‐Ortiz, G., Berglundh, T., Cairo, F., Derks, J., Figuero, E., Graziani, F., Guerra, F., Heitz‐Mayfield, L., et al. (2023) · Journal of Clinical Periodontology · doi:10.1111/jcpe.13808 · Cited by 107
Tonetti, M. S., Sanz, M., Avila‐Ortiz, G., Berglundh, T., Cairo, F., Derks, J., Figuero, E., Graziani, F., Guerra, F., Heitz‐Mayfield, L., et al. (2023) · Clinical Oral Implants Research · doi:10.1111/clr.14074 · Cited by 89
“, Fürhauser et al., 2005) via direct or indirect assessment (Cooper et al., 2021; Cosyn et al., 2021). a custom stent directly with a calibrated periodontal probe or indirectly with digital imaging assessments (e.g., standardized photographs or surface scans; Eghbali et al., 2018; Frizzera et al.,…”
Aesthetics and Patient‐Reported Outcomes in Periodontology and Implant Dentistry: Consensus Report
Tonetti, M., Sanz, M., Cairo, F., Nart, J., Chapple, I., Aimetti, M., Aroca, S., Avila‐Ortiz, G., Blanco, J., Bujaldón, A., et al. (2025) · Journal of Clinical Periodontology · doi:10.1111/jcpe.14182 · Cited by 31
“This scientific interest has pushed clinical research to develop and validate specific tools for evaluating aesthetic outcomes of therapy, using standardised approaches (Cairo et al. 2009; Furhauser et al. 2005), and to systematically assess patient experience and satisfaction after treatments.”
Avila‐Ortiz, G., Couso‐Queiruga, E., Pirc, M., Chambrone, L., & Thoma, D. S. (2023) · Journal of Clinical Periodontology · doi:10.1111/jcpe.13597 · Cited by 23
Metadata
- Authors
- Fürhauser, R., Florescu, D., Benesch, T., Haas, R., Mailath, G., & Watzek, G.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2005-11-14
- Volume
- 16
- Issue
- 6
- Pages
- 639-644
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W1910725442
- Cited by
- 978
- References
- 6
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.