CoChat

Factors affecting soft tissue level around anterior maxillary single‐tooth implants

Nisapakultorn, Kanokwan, Suphanantachat, Supreda, Silkosessak, Onanong, Rattanamongkolgul, Suthee · 2010 · Clinical Oral Implants Research
Cited by 189

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Background: Peri‐implant soft tissue recession is a major esthetic concern for the anterior implants. The aim of this study was to determine the factors that affected the facial marginal mucosal level and papilla level around single‐tooth implants in the anterior maxilla. Methods: Forty single‐tooth implants in the anterior maxilla were studied. Variables possibly associated with the soft tissue level were obtained from clinical measurements, study models, peri‐apical radiographs, and computerized tomograms. Fisher's exact test, analysis of variance, and binary logistic regression analysis were used to determine the influence of each factor on the facial marginal mucosal level and papilla level. Results: The majority of the implants (75%) replaced the upper central incisors. The facial mucosal margin of the implant was 0.5±0.9 mm more apical than that of the contralateral tooth. Half or more of papilla fill was observed in 89% of the samples. More apical level of the facial mucosal margin at the implant sites was significantly influenced by many factors including a thin peri‐implant biotype, a proclined implant fixture angle, more apical level of the facial bone crest, increased distance from the contact point to the bone crest, contact point to the platform, and contact point to implant bone. A thin biotype was the most significant factor in determining the facial marginal mucosal level. Increased distance from the contact point to the bone crest was the only factor significantly associated with less papilla fill. Conclusions: The papilla level around single‐tooth implants in the anterior maxilla was mainly influenced by the interproximal bone crest level of the adjacent tooth. Facial marginal mucosal level, on the other hand, was affected by multiple factors including the peri‐implant biotype, the facial bone crest level, the implant fixture angle, the interproximal bone crest level, the depth of implant platform, and the level of first bone to implant contact. To cite this article: Nisapakultorn K, Suphanantachat S, Silkosessak O, Rattanamongkolgul S. Factors affecting soft tissue level around anterior maxillary single‐tooth implants. Clin. Oral Impl. Res. 21, 2010; 662–670. doi: 10.1111/j.1600‐0501.2009.01887.x

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2009.01887.x

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 189

Metadata

Authors
Nisapakultorn, K., Suphanantachat, S., Silkosessak, O., & Rattanamongkolgul, S.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2010-05-11
Volume
21
Issue
6
Pages
662-670
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W1596882396
Cited by
189
References
11
FWCI
11.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.