The mucosal attachment at different abutments: An experimental study in dogs
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The present experiment was performed to examine if the material used in the abutment part of an implant system influenced the quality of the mucosal barrier that formed following implant installation. 5 beagle dogs were included in the study. The mandibular premolars and the 1st. 2nd and 3rd maxillary premolars were extracted. Three fixtures of the Brånemark System® were installed in each mandibular quadrant (a total of 6 fixtures per animal). Abutment connection was performed after 3 months of healing. In each dog the following types of abutments were used: 2 “control abutments” (c.p. titanium). 2 “ceramic abutments” (highly sintered Al 2 O 3), 1 “gold abutment”, and 1 “short titanium abutment”. This “short titanium abutment” was provided with an outer structure made of dental porcelain fused to gold. Following abutment connection a plaque control program was initiated and maintained for 6 months. The animals were sacrificed and perfused with a fixative. The mandibles were removed and each implant region was dissected, demineralized in EDTA and embedded in EPON®. Semithin sections representing the mesial, distal, buccal and lingual aspects of the peri‐implant tissues were produced and subjected to histological examination. The findings from the analysis demonstrated that the material used in the abutment portion of the implant influenced the location and the quality of the attachment that occurred between the periimplant mucosa and the implant. Abutments made of c.p. titanium or ceramic allowed the formation of a mucosal attachment which included one epithelial and one connective tissue portion that were about 2 mm and 1–1.5 mm high, respectively. At sites where abutments made of gold alloy or dental porcelain were used, no proper attachment formed at the abutment level, but the soft tissue margin receded and bone resorption occurred. The abutment fixture junction was hereby occasionally exposed and the mucosal barrier became established to the fixture portion of the implant. It was suggested that the observed differences were the result of varying adhesive properties of the materials studied or by variations in their resistance to corrosion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A formaldehyde - glutaraldehyde fixative of high osmolarity for use in electron microscopy
Karnovsky, M. J. (1965) · The Journal of Cell Biology · Cited by 5,882
The soft tissue barrier at implants and teeth
Berglundh, T., Lindhe, J., Ericsson, I., Marinello, C. P., Liljenberg, B., & Thornsen, P. (1991) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1991.020206.x · Cited by 901
Self-citationDimension of the periimplant mucosa: Biological width revisited
Berglundh, T., & Lindhe, J. (1996) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1996.tb00520.x · Cited by 798
Self-citationCochran, D. L., Hermann, J. S., Schenk, R. K., Higginbottom, F. L., & Buser, D. (1997) · Journal of Periodontology · doi:10.1902/jop.1997.68.2.186 · Cited by 504
Different types of inflammatory reactions in peri‐implant soft tissues
Ericsson, I., Persson, L. G., Berglundh, T., Marinello, C. P., Lindhe, J., & Klinge, B. (1995) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1995.tb00143.x · Cited by 421
Self-citationBerglundh, T., Lindhe, J., Marinell, C., Ericsson, I., & Liljenberg, B. (1992) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1992.030101.x · Cited by 411
Self-citationSoft Tissue Reactions to Non‐Submerged Unloaded Titanium Implants in Beagle Dogs
Buser, D., Weber, H. P., Donath, K., Fiorellini, J. P., Paquette, D. W., & Williams, R. C. (1992) · Journal of Periodontology · doi:10.1902/jop.1992.63.3.225 · Cited by 383
The topography of the vascular systems in the periodontal and peri‐implant tissues in the dog
Berglundh, T., Lindhe, J., Jonsson, K., & Ericsson, I. (1994) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1994.tb00302.x · Cited by 319
Self-citationLong‐standing plaque and gingivitis at implants and teeth in the dog
Ericsson, I., Berglundh, T., Marinello, C., Liljenberg, B., & Lindhe, J. (1992) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1992.030301.x · Cited by 308
Self-citationAbrahamsson, L., Berglundh, T., & Lindhe, J. (1998) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1998.090202.x · Cited by 186
Self-citation
Cited by
Infectious risks for oral implants: a review of the literature
Quirynen, M., De Soete, M., & Van Steenberghe, D. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130101.x · Cited by 665
Soft tissue wound healing around teeth and dental implants
Sculean, A., Gruber, R., & Bosshardt, D. D. (2014) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12206 · Cited by 439
Sailer, I., Philipp, A., Zembic, A., Pjetursson, B. E., Hämmerle, C. H. F., & Zwahlen, M. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01787.x · Cited by 368
Rompen, E., Domken, O., Degidi, M., Farias Pontes, A. E., & Piattelli, A. (2006) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2006.01367.x · Cited by 356
Significance of Keratinized Mucosa in Maintenance of Dental Implants With Different Surfaces
Chung, D. M., Oh, T., Shotwell, J. L., Misch, C. E., & Wang, H. (2006) · Journal of Periodontology · doi:10.1902/jop.2006.050393 · Cited by 313
The mucosal barrier at implant abutments of different materials
Welander, M., Abrahamsson, I., & Berglundh, T. (2008) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2008.01543.x · Cited by 293
Self-citationZembic, A., Sailer, I., Jung, R. E., & Hämmerle, C. H. F. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01717.x · Cited by 263
Comparison of peri‐implant and periodontal marginal soft tissues in health and disease
Ivanovski, S., & Lee, R. (2018) · Periodontology 2000 · doi:10.1111/prd.12150 · Cited by 255
Zirconia in biomedical applications
Chen, Y.-W., Moussi, J., Drury, J. L., & Wataha, J. C. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1230017 · Cited by 238
“It has been shown that zirconia and titanium alloy abutments exhibit equivalent compatibility for connective tissue integration and the formation of epithelial tissue attachment; the connective tissue attachment around the zirconia abutments form a more stable mucosal seal than the conventional gold abutments [71].”
BackgroundSchwarz, F., Ferrari, D., Herten, M., Mihatovic, I., Wieland, M., Sager, M., & Becker, J. (2007) · Journal of Periodontology · doi:10.1902/jop.2007.070157 · Cited by 211
Bio-inspired stable antimicrobial peptide coatings for dental applications
Holmberg, K. V., Abdolhosseini, M., Li, Y., Chen, X., Gorr, S.-U., & Aparicio, C. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.06.017 · Cited by 210
Abrahamsson, I., Zitzmann, N. U., Berglundh, T., Linder, E., Wennerberg, A., & Lindhe, J. (2002) · Journal of Clinical Periodontology · doi:10.1034/j.1600-051x.2002.290510.x · Cited by 194
Self-citationGlauser, R., Schüpbach, P., Gottlow, J., & Hämmerle, C. H. F. (2005) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2005.tb00074.x · Cited by 192
Guo, T., Gulati, K., Arora, H., Han, P., Fournier, B., & Ivanovski, S. (2021) · Dental Materials · doi:10.1016/j.dental.2021.02.005 · Cited by 180
Araujo, M. G., & Lindhe, J. (2018) · Journal of Periodontology · doi:10.1002/jper.16-0424 · Cited by 173
Self-citationCritical soft‐tissue dimensions with dental implants and treatment concepts
Thoma, D. S., Mühlemann, S., & Jung, R. E. (2014) · Periodontology 2000 · doi:10.1111/prd.12045 · Cited by 171
Zembic, A., Kim, S., Zwahlen, M., & Kelly, J. R. (2014) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.2014suppl.g2.2 · Cited by 166
The biological width around implant
Zheng, Z., Ao, X., Xie, P., Jiang, F., & Chen, W. (2021) · Journal of Prosthodontic Research · doi:10.2186/jpr.jpor_2019_356 · Cited by 84
Metadata
- Authors
- Abrahamsson, I., Berglundh, T., Glantz, P. ‐., & Lindhe, J.
- Venue
- Journal of Clinical Periodontology
- Publisher
- Wiley
- Published
- 1998-09
- Volume
- 25
- Issue
- 9
- Pages
- 721-727
- ISSN
- 0303-6979 (ISSN-L)
- 1600-051X
- OpenAlex
- W1770820332
- Cited by
- 384
- References
- 12
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.