Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Effective ventilation in general hospital wards is important for controlling the airborne transmission of infectious respiratory diseases. Experiments have been carried out to increase our understanding of the interaction of the breathing flows of two individuals in a full-scale experimental hospital ward with three ventilation systems, i.e. mixing, downward and displacement ventilation. Two life-size breathing thermal manikins were used to simulate a source patient and a receiving patient. The exhalation jet from a bed-lying manikin was visualized using smoke. N2O was used as tracer gas to simulate the droplet nuclei exhaled by patients; and the spatial distribution of its concentrations was measured. Our experimental results show that for both mixing and downward ventilation, the exhaled jet penetrates a short distance and is diluted quickly by ventilation air. The exhaled droplet nuclei are well mixed in the ward. Bed distance does not affect the personal exposure of the receiving patient. For displacement ventilation, the exhaled jet can penetrate a long distance. A high concentration layer of exhaled droplet nuclei because of thermal stratification locking has also been observed with displacement ventilation. This work is useful for identifying an appropriate ventilation method that can remove droplet nuclei more effectively and minimize the risk of cross-infections in a hospital ward environment. PRACTICAL IMPLICATIONS: As one of the major potential sources for infectious droplet nuclei in a hospital environment, exhalation flows of an infected patient can interact with the respiratory activities of other close individuals and with the room ventilation systems. Our latest results provide information on the penetration of exhalation jets into the ambient environment in different ventilation systems. This work is useful in identifying an appropriate and effective ventilation method for removing droplet nuclei more effectively, and thus minimizing the risk of cross-infections in hospital wards with multiple beds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Rudnick, S. N., & Milton, D. K. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00189.x · Cited by 624
Spengler, J. D., McCarthy, J. F., & Samet, J. M. (2000) · Cited by 574
Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong
Li, Y., Huang, X., Yu, I. T. S., Wong, T. W., & Qian, H. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00317.x · Cited by 414
Self-citationCough-generated Aerosols of Mycobacterium tuberculosis: A New Method to Study Infectiousness
Fennelly, K. P., Martyny, J. W., Fulton, K. E., Orme, I. M., Cave, D. M., & Heifets, L. B. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200308-1101oc · Cited by 327
Cole, E. C., & Cook, C. E. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70046-x · Cited by 317
Bjørn, E., & Nielsen, P. V. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.08126.x · Cited by 294
Self-citationAirborne Infection: Theoretical Limits of Protection Achievable by Building Ventilation
Nardell, E. A., Keegan, J., Cheney, S. A., & Etkind, S. C. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.2.302 · Cited by 261
Hospital Ventilation and Risk for Tuberculous Infection in Canadian Health Care Workers
Menzies, D., Fanning, A., Yuan, L., FitzGerald, J. M., & and the Canadian Collaborative Group in Nosocomial Transmission of TB* (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-10-200011210-00010 · Cited by 212
SARS: experience at Prince of Wales Hospital, Hong Kong
Tomlinson, B., & Cockram, C. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13218-7 · Cited by 158
Temperatures of expired air under varying climatic conditions
Höppe, P. (1981) · International Journal of Biometeorology · doi:10.1007/bf02184460 · Cited by 128
Fraser, V. J., Johnson, K. M., Primack, J., Jones, M., Medoff, G., & Dunagan, W. C. (1993) · Infection Control and Hospital Epidemiology · doi:10.1086/646654 · Cited by 74
Airborne Contagion and Air Hygiene: An Ecological Study of Droplet Infection
(1957) · Tubercle · doi:10.1016/s0041-3879(57)80076-2 · Cited by 58
Personal Exposure to Contaminant Sources in Ventilated Rooms
Brohus, H. (1997) · VBN Forskningsportal (Aalborg Universitet) · Cited by 56
An Evaluation of Hospital Special-Ventilation-Room Pressures
Rice, N., Streifel, A. J., & Vesley, D. (2001) · Infection Control and Hospital Epidemiology · doi:10.1086/501819 · Cited by 51
Inefficiency of upward displacement operating theatre ventilation
Friberg, B., Friberg, S., BURMAN, L. G., Lundholm, R., & Östensson, R. (1996) · Journal of Hospital Infection · doi:10.1016/s0195-6701(96)90012-2 · Cited by 47
Geometrical models for the high-frequency dielectric properties of brine saturated sandstones
Tyč, S., Schwartz, L. M., Sen, P. N., & Wong, P. (1988) · Journal of Applied Physics · doi:10.1063/1.341645 · Cited by 39
Sutton, P. M., Nicas, M., & Harrison, R. J. (2000) · Infection Control and Hospital Epidemiology · doi:10.1086/501693 · Cited by 33
Yassi, A., Bryce, E., Moore, D., Janssen, R., Copes, R., Bartlett, K. H., Fitzgerald, M., Gilbert, M., Bigelow, P., Danyluk, Q., et al. (2023) · doi:10.32920/23935254 · Cited by 10
Cited by
How far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curve
Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L., & Seto, W. H. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00469.x · Cited by 966
Self-citationTang, J. W., Li, Y., Eames, I., Chan, P. K. S., & Ridgway, G. L. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.05.022 · Cited by 667
Self-citationAerosol transmission of influenza A virus: a review of new studies
Tellier, R. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0302.focus · Cited by 589
Exhaled droplets due to talking and coughing
Xie, X., Li, Y., Sun, H., & Liu, L. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0388.focus · Cited by 527
Self-citationA review of the performance of different ventilation and airflow distribution systems in buildings
Cao, G., Awbi, H., Yao, R., Fan, Y., Sirén, K., Kosonen, R., & Zhang, J. (. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.12.009 · Cited by 525
Metadata
- Authors
- Qian, H., Li, Y., Nielsen, P. V., Hyldgaard, C. E., Wong, T. W., & Chwang, A. T. Y.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2006-04
- Volume
- 16
- Issue
- 2
- Pages
- 111-128
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2122697068
- Cited by
- 294
- References
- 19
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.