How far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curve
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
UNLABELLED: A large number of infectious diseases are believed to be transmitted between people via large droplets and by airborne routes. An understanding of evaporation and dispersion of droplets and droplet nuclei is not only significant for developing effective engineering control methods for infectious diseases but also for exploring the basic transmission mechanisms of the infectious diseases. How far droplets can move is related to how far droplet-borne diseases can transmit. A simple physical model is developed and used here to investigate the evaporation and movement of droplets expelled during respiratory activities; in particular, the well-known Wells evaporation-falling curve of droplets is revisited considering the effect of relative humidity, air speed, and respiratory jets. Our simple model considers the movement of exhaled air, as well as the evaporation and movement of a single droplet. Exhaled air is treated as a steady-state non-isothermal (warm) jet horizontally issuing into stagnant surrounding air. A droplet is assumed to evaporate and move in this non-isothermal jet. Calculations are performed for both pure water droplets and droplets of sodium chloride (physiological saline) solution (0.9% w/v). We calculate the droplet lifetimes and how droplet size changes, as well as how far the droplets travel in different relative humidities. Our results indicate that a droplet's size predominately dictates its evaporation and movement after being expelled. The sizes of the largest droplets that would totally evaporate before falling 2 m away are determined under different conditions. The maximum horizontal distances that droplets can reach during different respiratory activities are also obtained. Our study is useful for developing effective prevention measures for controlling infectious diseases in hospitals and in the community at large. PRACTICAL IMPLICATIONS: Our study reveals that for respiratory exhalation flows, the sizes of the largest droplets that would totally evaporate before falling 2 m away are between 60 and 100 microm, and these expelled large droplets are carried more than 6 m away by exhaled air at a velocity of 50 m/s (sneezing), more than 2 m away at a velocity of 10 m/s (coughing) and less than 1 m away at a velocity of 1 m/s (breathing). These findings are useful for developing effective engineering control methods for infectious diseases, and also for exploring the basic transmission mechanisms of the infectious diseases. There is a need to examine the air distribution systems in hospital wards for controlling both airborne and droplet-borne transmitted diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiphase Flows with Droplets and Particles
Crowe, C. T., Schwarzkopf, J. D., Sommerfeld, M., & Tsuji, Y. (2011) · doi:10.1201/b11103 · Cited by 3,076
(2006) · A-to-Z Guide to Thermodynamics, Heat and Mass Transfer, and Fluids Engineering · doi:10.1615/atoz.e.evaofdrop · Cited by 2,132
Some measurements in the self-preserving jet
Wygnanski, I., & Fiedler, H. (1969) · Journal of Fluid Mechanics · doi:10.1017/s0022112069000358 · Cited by 1,314
Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus
Yu, I. T. S., Li, Y., Wong, T. W., Tam, W., Chan, A. T., Lee, J. H. W., Leung, D. Y. C., & Ho, T. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032867 · Cited by 1,256
Self-citationAwbi, H. B. (2002) · Routledge eBooks · doi:10.4324/9780203476307 · Cited by 900
Control of Communicable Diseases Manual
(1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-7-199710010-00025 · Cited by 871
Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867 · cited 2×
“, 2004; Hamburger and Roberston, 1946; Jennison, 1942; Loudon and Roberts, 1967; Papineni and Rosenthal, 1997) and excellent reviews exist (Morawska, 2005; Nicas et al., 2005).”
BackgroundThe size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 3×
“There have been a number of studies on the number and size of droplets of saliva and other secretions from respiratory activities (Duguid, 1945; Fennelly et al., 2004; Hamburger and Roberston, 1946; Jennison, 1942; Loudon and Roberts, 1967; Papineni and Rosenthal, 1997) and excellent reviews exist (Morawska, 2005; Nic…”
BackgroundEvaporation and Droplet Growth in Gaseous Media
Fuchs, N. A., Pratt, J. N., & Sabersky, R. H. (1960) · Journal of Applied Mechanics · doi:10.1115/1.3644122 · Cited by 569
Transmission of infectious diseases during commercial air travel
Mangili, A., & Gendreau, M. A. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71089-8 · Cited by 535
Indirect health effects of relative humidity in indoor environments.
Arundel, A. V., Sterling, E. M., Biggin, J. H., & Sterling, T. D. (1986) · Environmental Health Perspectives · doi:10.1289/ehp.8665351 · Cited by 525
Vertical turbulent buoyant jets : a review of experimental data
Chen, C. J., & Rodi, W. (1980) · Pergamon Press eBooks · Cited by 497
Direct simulation of particle dispersion in a decaying isotropic turbulence
Elghobashi, S., & Truesdell, G. C. (1992) · Journal of Fluid Mechanics · doi:10.1017/s0022112092002532 · Cited by 441
Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong
Li, Y., Huang, X., Yu, I. T. S., Wong, T. W., & Qian, H. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00317.x · Cited by 414
Self-citationDilution of Respiratory Solutes in Exhaled Condensates
EFFROS, R. M., HOAGLAND, K. W., BOSBOUS, M., CASTILLO, D., FOSS, B., DUNNING, M., GARE, M., LIN, W., & SUN, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2101018 · Cited by 386
Cough-generated Aerosols of Mycobacterium tuberculosis: A New Method to Study Infectiousness
Fennelly, K. P., Martyny, J. W., Fulton, K. E., Orme, I. M., Cave, D. M., & Heifets, L. B. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200308-1101oc · Cited by 327
Cole, E. C., & Cook, C. E. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70046-x · Cited by 317
Qian, H., Li, Y., Nielsen, P. V., Hyldgaard, C. E., Wong, T. W., & Chwang, A. T. Y. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00407.x · Cited by 294
Self-citationPossible SARS Coronavirus Transmission during Cardiopulmonary Resuscitation
Christian, M. D., Loutfy, M., McDonald, L. C., Martinez, K. F., Ofner, M., Wong, T., Wallington, T., Gold, W. L., Mederski, B., Green, K., et al. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030700 · Cited by 274
Airborne Contagion and Air Hygiene
Phair, J. J. (1955) · American Journal of Public Health and the Nations Health · doi:10.2105/ajph.45.11.1495-c · Cited by 257
Mendell, M. J., Fisk, W. J., Kreiss, K., Levin, H., Alexander, D., Cain, W. S., Girman, J. R., Hines, C. J., Jensen, P. A., Milton, D. K., et al. (2002) · American Journal of Public Health · doi:10.2105/ajph.92.9.1430 · Cited by 229
Spread and prevention of some common viral infections in community facilities and domestic homes
Barker, J., Stevens, D., & Bloomfield, S. F. (2001) · Journal of Applied Microbiology · doi:10.1046/j.1365-2672.2001.01364.x · Cited by 220
Barrett, J. C., & Clement, C. F. (1988) · Journal of Aerosol Science · doi:10.1016/0021-8502(88)90225-x · Cited by 161
Particle turbulent diffusion in a dust laden round jet
Yuu, S., Yasukouchi, N., Hirosawa, Y., & Jotaki, T. (1978) · AIChE Journal · doi:10.1002/aic.690240316 · Cited by 152
Airborne infection : transmission and control
Riley, R. L., & O'Grady, F. (1961) · University of Michigan Library Repository · Cited by 147
Riley, R. L. (1974) · The American Journal of Medicine · doi:10.1016/0002-9343(74)90140-5 · Cited by 133
TELEMAN, M. D., BOUDVILLE, I. C., HENG, B. H., ZHU, D., & LEO, Y. S. (2004) · Epidemiology and Infection · doi:10.1017/s0950268804002766 · Cited by 130 · cited 1×
“Embil et al. (2003), Teleman et al. (2004) and Langley (2005) deemed the short distance to be 1 or 1.5 m from the source person.”
BackgroundInfluentialTemperatures of expired air under varying climatic conditions
Höppe, P. (1981) · International Journal of Biometeorology · doi:10.1007/bf02184460 · Cited by 128
Indirect Health Effects of Relative Humidity in Indoor Environments
Arundel, A. V., Sterling, E. M., Biggin, J. H., & Sterling, T. D. (1986) · Environmental Health Perspectives · doi:10.2307/3430203 · Cited by 112
The interdependence of evaporation and settling for airborne freely falling droplets
Kukkonen, J., Vesala, T., & Kulmala, M. (1989) · Journal of Aerosol Science · doi:10.1016/0021-8502(89)90087-6 · Cited by 99
Common Colds and related Diseases
Tyrrell, D. A. J. (1966) · Public Health · doi:10.1016/s0033-3506(66)80038-0 · Cited by 76
Study of SARS Transmission Via Liquid Droplets in Air
Wang, B., Zhang, A., Sun, J. L., Liu, H., Hu, J., & Xu, L. X. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1835350 · Cited by 75
Fundamentals of industrial ventilation
Baturin, V. V. (1972) · Medical Entomology and Zoology · Cited by 73
Loudon, R. G., & ROBERTS, R. M. (1967) · Nature · doi:10.1038/213095a0 · Cited by 71
Hamburger, M., & ROBERTSON, O. H. (1948) · The American Journal of Medicine · doi:10.1016/s0002-9343(48)90392-1 · Cited by 65
Rutala, W. A., Jones, S. M., Worthington, J., Reist, P. C., & Weber, D. J. (1995) · Infection Control and Hospital Epidemiology · doi:10.1086/647136 · Cited by 55
Yassi, A., Bryce, E., Moore, D., Janssen, R., Copes, R., Bartlett, K. H., Fitzgerald, M., Gilbert, M., Bigelow, P., Danyluk, Q., et al. (2023) · doi:10.32920/23935254 · Cited by 10
Cited by
Airborne transmission of respiratory viruses
Wang, C. C., Prather, K. A., Sznitman, J., Jimenez, J. L., Lakdawala, S. S., Tufekci, Z., & Marr, L. C. (2021) · Science · doi:10.1126/science.abd9149 · Cited by 1,543
Jayaweera, M., Perera, H., Gunawardana, B., & Manatunge, J. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109819 · Cited by 1,238
It is time to address airborne transmission of coronavirus disease 2019 (COVID-19)
Morawska, L., & Milton, D. K. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa939 · Cited by 1,189
Aerosol Emission and Superemission during Human Speech Increase with Voice Loudness
Asadi, S., Wexler, A. S., Cappa, C. D., Barreda, S., Bouvier, N. M., & Ristenpart, W. D. (2019) · Scientific Reports · doi:10.1038/s41598-019-38808-z · Cited by 919
Transmissibility and transmission of respiratory viruses
Leung, N. H. L. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-021-00535-6 · Cited by 890
Metadata
- Authors
- Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L., & Seto, W. H.
- Venue
- Indoor Air
- Publisher
- Wiley
- Published
- 2007-06
- Volume
- 17
- Issue
- 3
- Pages
- 211-225
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W1979081004
- Cited by
- 966
- References
- 37
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.