The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Effects of thermal discomfort in an office on perceived air quality, SBS symptoms, physiological responses, and human performance: The effects of thermal discomfort on health and human performance
Abstract
UNLABELLED: The effects of thermal discomfort on health and human performance were investigated in an office, in an attempt to elucidate the physiological mechanisms involved. Twelve subjects (six men and six women) performed neurobehavioral tests and tasks typical of office work while thermally neutral (at 22°C) and while warm (at 30°C). Multiple physiological measurements and subjective assessment were made. The results show that when the subjects felt warm, they assessed the air quality to be worse, reported increased intensity of many sick building syndrome symptoms, expressed more negative mood, and were less willing to exert effort. Task performance decreased when the subjects felt warm. Their heart rate, respiratory ventilation, and end-tidal partial pressure of carbon dioxide increased significantly, and their arterial oxygen saturation decreased. Tear film quality was found to be significantly reduced at the higher temperature when they felt warm. No effects were observed on salivary biomarkers (alpha-amylase and cortisol). The present results imply that the negative effects on health and performance that occur when people feel thermally warm at raised temperatures are caused by physiological mechanisms. PRACTICAL IMPLICATIONS: This study indicates to what extent elevated temperatures and thermal discomfort because of warmth result in negative effects on health and performance and shows that these could be caused by physiological responses to warmth, not by the distraction of subjective discomfort. This implies that they will occur independently of discomfort, i.e. even if subjects have become adaptively habituated to subjective discomfort. The findings make it possible to estimate the negative economic consequences of reducing energy use in buildings in cases where this results in elevated indoor temperatures. They show clearly that thermal discomfort because of raised temperatures should be avoided in workplaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007) · Behavior Research Methods · doi:10.3758/bf03193146 · Cited by 65,971
Thermal comfort: Analysis and applications in environmental engineering
(1972) · Applied Ergonomics · doi:10.1016/s0003-6870(72)80074-7 · Cited by 4,451
ASHRAE Handbook—1981 Fundamentals
(1981) · Building Services Engineering Research and Technology · doi:10.1177/014362448100200409 · Cited by 3,403
Salivary cortisol as a biomarker in stress research
Hellhammer, D. H., Wüst, S., & Kudielka, B. M. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.10.026 · Cited by 1,925
Nater, U. M., & Rohleder, N. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2009.01.014 · Cited by 1,370
WARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Self-citationDeterminants of salivary α-amylase in humans and methodological considerations
Rohleder, N., & Nater, U. M. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.12.004 · Cited by 604
Impact of Temperature and Humidity on the Perception of Indoor Air Quality
Fang, L., Clausen, G., & Fanger, P. O. (1998) · Indoor Air · doi:10.1111/j.1600-0668.1998.t01-2-00003.x · Cited by 534
Wargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507
Self-citationFang, L., Wyon, D. P., Clausen, G., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00276.x · Cited by 380
Self-citationPrinciples of psychophysiology
(1991) · Comparative Biochemistry and Physiology Part A: Physiology · doi:10.1016/0300-9629(91)90347-f · Cited by 367
Wargocki, P., & Wyon, D. P. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10390951 · Cited by 364
Self-citationLan, L., & Lian, Z. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.11.002 · Cited by 360
Self-citationCreating the Productive Workplace: Places to Work Creatively
(2006) · Taylor & Francis eBooks · doi:10.4324/9780203696880 · Cited by 358
Roelofsen, P. (2002) · Journal of Facilities Management · doi:10.1108/14725960310807944 · Cited by 351
Noise, stress, and annoyance in a pediatric intensive care unit
Morrison, W. E., Haas, E. C., Shaffner, D. H., Garrett, E. S., & Fackler, J. C. (2003) · Critical Care Medicine · doi:10.1097/00003246-200301000-00018 · Cited by 281
Evaluation of cognitive performance in the heat by functional brain imaging and psychometric testing
Hocking, C., Silberstein, R. B., Lau, W. M., Stough, C., & Roberts, W. (2001) · Comparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology · doi:10.1016/s1095-6433(01)00278-1 · Cited by 268
The effect of air temperature on labour productivity in call centres—a case study
Niemelä, R., Hannula, M., Rautio, S., Reijula, K., & Railio, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00094-4 · Cited by 233
Assessment of productivity loss in air-conditioned buildings using PMV index
Kosonen, R., & Tan, F. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.06.021 · Cited by 228
Witterseh, T., Wyon, D. P., & Clausen, G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00305.x · Cited by 227
Self-citationWorkload Assessment and Prediction
Hart, S. G., & Wickens, C. D. (1990) · Manprint · doi:10.1007/978-94-009-0437-8_9 · Cited by 225
Fang, L., Clausen, G., & Fanger, P. O. (1998) · Indoor Air · doi:10.1111/j.1600-0668.1998.00008.x · Cited by 202
Lan, L., Lian, Z., Pan, L., & Ye, Q. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.10.004 · Cited by 196
Self-citationRoom temperature and productivity in office work
Seppänen, O., Fisk, W. J., & Lei, Q. (2006) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 187
Upper limits of air humidity for preventing warm respiratory discomfort
Toftum, J., Jørgensen, A. S., & Fanger, P. O. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00018-2 · Cited by 183
Use of neurobehavioral tests to evaluate the effects of indoor environment quality on productivity
Lan, L., & Lian, Z. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.02.001 · Cited by 183
Self-citationAdaptation to indoor air pollution
Gunnarsen, L., & Fanger, P. O. (1992) · Environment International · doi:10.1016/0160-4120(92)90209-m · Cited by 165
Room air temperature affects occupants’ physiology, perceptions and mental alertness
Tham, K. W., & Willem, H. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.04.002 · Cited by 151
The supply of glucose to the brain and cognitive functioning
Benton, D., Parker, P. Y., & Fothergill, R. T. (1996) · Journal of Biosocial Science · doi:10.1017/s0021932000022537 · Cited by 124
Indoor thermal factors and symptoms in office workers: findings from the US EPA BASE study
Mendell, M. J., & Mirer, A. G. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00592.x · Cited by 115
Tham, K. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00280.x · Cited by 115
Miyake, S., & Kumashiro, M. (1993) · The Japanese Journal of Ergonomics · doi:10.5100/jje.29.399 · Cited by 114
Temperature and learning: An experimental study.
PEPLER, R. D., & Warner, R. (1968) · ASHRAE winter conference papers · Cited by 109
Indoor Particles and Symptoms Among Office Workers: Results from a Double-Blind Cross-Over Study
Mendell, M. J., Fisk, W. J., Petersen, M. R., Hines, C. J., Dong, M., Faulkner, D. M., Deddens, J. A., Ruder, A. M., Sullivan, D. P., & Boeniger, M. F. (2002) · Epidemiology · doi:10.1097/00001648-200205000-00010 · Cited by 102
Tanabe, S., & Nishihara, N. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00281.x · Cited by 90
Fuels for memory: the role of oxygen and glucose in memory enhancement
Winder, R. E., & Borrill, J. (1998) · Psychopharmacology · doi:10.1007/s002130050577 · Cited by 72
The Mental Performance of Subjects Clothed for Comfort at Two Different Air Temperatures
Wyon, D. P., Fanger, P. O., Olesen, B. W., & PEDERSON, C. J. K. (1975) · Ergonomics · doi:10.1080/00140137508931470 · Cited by 70
Self-citationHypercapnia in obstructive sleep apnoea syndrome
Resta, O., Barbaro, M. P. F., Bonfitto, P., Talamo, S., Mastrosimone, V., Stefano, A. D., & Giliberti, T. (2000) · The Netherlands Journal of Medicine · doi:10.1016/s0300-2977(00)00024-3 · Cited by 67
Wientjes, C., Grossman, P., & Gaillard, A. (1998) · Biological Psychology · doi:10.1016/s0301-0511(98)00026-x · Cited by 63
Wientjes, C. J. E., Grossman, P., & Gaillard, A. W. K. (1998) · PubMed · Cited by 62
Toftum, J., Langkilde, G., & Fanger, P. O. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.02.001 · Cited by 53
HEERWAGEN, J. H., Heubach, J. G., Montgomery, J., et al. (1995) · PubMed · Cited by 46
Productivity and Health Effects of High Indoor Air Quality
Wargocki, P. L. (2011) · Elsevier eBooks · doi:10.1016/b978-0-444-52272-6.00270-1 · Cited by 39
Self-citationJohnson, A. K., & Anderson, E. A. (1990) · Cited by 39
Toftum, J., Wyon, D. P., Svanekjær, H., & Lantner, A. (2005) · Cited by 32
Self-citationOxygen saturation and cognitive performance
Andersson, J., Berggren, P., Grönkvist, M., Magnusson, S., & Svensson, E. (2002) · Psychopharmacology · doi:10.1007/s00213-002-1077-3 · Cited by 30
Cortisol as a biomarker of stress
Clow, A. (2004) · WestminsterResearch (University of Westminster) · Cited by 24
Willem, H., Olesen, B. W., & Wargocki, P. L. (2006) · National University of Singapore · Cited by 18
Self-citationHaneda, M., Wargocki, P. L., Dalewski, M., & Tanabe, S. (2009) · Cited by 7
Self-citation
Cited by
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
Indoor air humidity, air quality, and health – An overview
Wolkoff, P. (2018) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2018.01.015 · Cited by 662
Quantitative measurement of productivity loss due to thermal discomfort
Lan, L., Wargocki, P., & Lian, Z. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2010.09.001 · Cited by 442
Self-citationChoi, H.-H., van Merriënboer, J. J. G., & Paas, F. (2014) · Educational Psychology Review · doi:10.1007/s10648-014-9262-6 · Cited by 413
A review of indoor air treatment technologies
Luengas, A., Barona, A., Hort, C., Gallastegui, G., Platel, V., & Elias, A. (2015) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-015-9363-9 · Cited by 360
Metadata
- Authors
- Lan, L., Wargocki, P., Wyon, D. P., & Lian, Z.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2011-04-18
- Volume
- 21
- Issue
- 5
- Pages
- 376-390
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2144711546
- Cited by
- 355
- References
- 49
- FWCI
- 16.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.