Benefits and costs of improved IEQ in U.S. offices
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
UNLABELLED: This study estimates some of the benefits and costs of implementing scenarios that improve indoor environmental quality (IEQ) in the stock of U.S. office buildings. The scenarios include increasing ventilation rates when they are below 10 or 15 l/s per person, adding outdoor air economizers and controls when absent, eliminating winter indoor temperatures >23°C, and reducing dampness and mold problems. The estimated benefits of the scenarios analyzed are substantial in magnitude, including increased work performance, reduced Sick Building Syndrome symptoms, reduced absence, and improved thermal comfort for millions of office workers. The combined potential annual economic benefit of a set of nonoverlapping scenarios is approximately $20 billion. While the quantitative estimates have a high uncertainty, the opportunity for substantial benefits is clear. Some IEQ improvement measures will save energy while improving health or productivity, and implementing these measures should be the highest priority. PRACTICAL IMPLICATIONS: Owners, designers, and operators of office buildings have an opportunity to improve IEQ, health, work performance, and comfort of building occupants and to obtain economic benefits by improving IEQ. These benefits can be achieved with simultaneous energy savings or with only small increases in energy costs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055 · cited 2×
“2004) and there is a body of evidence (Li et al. 2007) indicating that lower VRs increase respiratory infections, which are a major cause of absence.”
BackgroundMeta-analyses of the associations of respiratory health effects with dampness and mold in homes
Fisk, W. J., Lei-Gomez, Q., & Mendell, M. J. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00475.x · Cited by 681 · cited 1×
“Although this analysis of scenario 4 relies on the findings of only this single study, a large body of evidence indicates that workplace and home dampness are associated with increased respiratory symptoms and respiratory infections (Fisk et al. 2007; Mudarri and Fisk 2007; Fisk et al. 2010).”
BackgroundSelf-citationFisk, W. J. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.537 · Cited by 557 · cited 6×
“The combined potential annual economic benefit of the non-overlapping scenarios is either $17 billion or $26 billion, depending on the source of data on existing VRs. Fisk (Fisk 2000) described a prior analysis of the benefits attainable from improving IEQ conditions in U.S. buildings, but only general comparisons of…”
BackgroundMethodResultInfluentialSelf-citationEstimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 549 · cited 3×
“The analyses in this paper build upon many prior related analyses, e.g., (Fisk and Rosenfeld 1997; Mendell et al. 2002; Wargocki and Djukanovic 2005; Wargocki et al. 2006) and upon the work of scientists from around the world who have investigated the associations of IEQ parameters with people’s…”
BackgroundMethodSelf-citationAssociations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462 · cited 2×
“…because of the reliance on the results of a single study; however, supportive findings are available from a study of VRs and absence in classrooms (Shendell et al. 2004) and there is a body of evidence (Li et al. 2007) indicating that lower VRs increase respiratory infections, which are a major…”
BackgroundResultSelf-citationQuantitative measurement of productivity loss due to thermal discomfort
Lan, L., Wargocki, P., & Lian, Z. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2010.09.001 · Cited by 442 · cited 4×
“Two other models described by (Lan et al. 2010) indicate substantially larger decrements in performance as temperature (or thermal comfort) deviates from the optimum value for work performance.”
BackgroundMethodResultInfluentialMILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364 · cited 1×
“The findings of a single study in 40 buildings (Milton et al. 2000) were employed to estimate the quantitative relationship of office VR with short term absence.”
BackgroundPublic health and economic impact of dampness and mold
Mudarri, D., & Fisk, W. J. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00474.x · Cited by 319 · cited 1×
“Although this analysis of scenario 4 relies on the findings of only this single study, a large body of evidence indicates that workplace and home dampness are associated with increased respiratory symptoms and respiratory infections (Fisk et al. 2007; Mudarri and Fisk 2007; Fisk et al. 2010).”
BackgroundSelf-citationVentilation and performance in office work
Seppanen, O., Fisk, W. J., & Lei, Q. H. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00394.x · Cited by 303 · cited 3×
“For the relationship of VRs in offices with office work performance (Seppanen et al. 2006), the following equation was employed Ventilation rates and work performance”
MethodInfluentialSelf-citation
Cited by
Sustainability in the construction industry: A systematic review of the literature
Lima, L., Trindade, E., Alencar, L., Alencar, M., & Silva, L. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.125730 · Cited by 406
A review of indoor air treatment technologies
Luengas, A., Barona, A., Hort, C., Gallastegui, G., Platel, V., & Elias, A. (2015) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-015-9363-9 · Cited by 360
Labeodan, T., Zeiler, W., Boxem, G., & Zhao, Y. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.02.028 · Cited by 322
Capturing the Multiple Benefits of Energy Efficiency: A Guide to Quantifying the Value Added
International Energy Agency (2014) · OECD eBooks · doi:10.1787/9789264220720-en · Cited by 252
A Method to Estimate the Chronic Health Impact of Air Pollutants in U.S. Residences
Logue, J. M., Price, P. N., Sherman, M. H., & Singer, B. C. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104035 · Cited by 251
Liang, H.-H., Chen, C.-P., Hwang, R.-L., Shih, W.-M., Lo, S.-C., & Liao, H.-Y. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.11.007 · Cited by 240
Choi, Y., Kim, M., & Chun, C. (2015) · Building and Environment · doi:10.1016/j.buildenv.2014.10.003 · Cited by 173
Metadata
- Authors
- Fisk, W. J., Black, D., & Brunner, G.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2011-05-04
- Volume
- 21
- Issue
- 5
- Pages
- 357-367
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2168136215
- Cited by
- 162
- References
- 19
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.