Clinical microneedle injection of methyl nicotinate: stratum corneum penetration
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background/purpose:In recent years, microneedles were proposed as a method to painlessly deliver drugs past the stratum corneum. Microneedles have been fabricated in several designs, but limited studies have tested microneedle injections in humans. In this work, we compare microneedle injections with topical application (TA) to investigate if microneedles enhance in vivo drug delivery past the stratum corneum. Method:In vitro tests were used to measure microneedle pressures and injection volumes.In vivo microneedle injections were performed on the volar forearm of 11 healthy volunteers. Two sets of microneedles, pointed and symmetric, were used to develop microneedle/syringe apparatuses that were used to inject approximately 1 μL of 0.1 M methyl nicotinate, and were compared against TA. A Laser Doppler Perfusion Monitor was used to record maximum blood flow and the time to maximum blood flow at the treatment sites. Results:Pointed and symmetric microneedle‐injected sites showed a significantly faster time to maximum blood flow than TA. The pointed microneedle injections also resulted in a higher maximum blood flux. Volunteers reported feeling pressure but no pain from the microneedles during the injections. Conclusion:The microneedles aid in bypassing the stratum corneum and enhance drug delivery through it. The design of the microneedle influences its delivery capabilities, because the pointed microneedles seem to be less susceptible to clogging during the injection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859 · cited 2×
“(11) used a single glass microneedle to inject insulin into diabetic rats and reduce their blood glucose by 70%.”
BackgroundMethodSilicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413 · cited 1×
“(12) infused insulin into diabetic rats through a microneedle array and showed that it was comparable to subcutaneous insulin injection.”
Background
Cited by
Polymers for 3D Printing and Customized Additive Manufacturing
Ligon, S. C., Liska, R., Stampfl, J., Gurr, M., & Mülhaupt, R. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00074 · Cited by 3,741
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Microneedle-based drug delivery systems: Microfabrication, drug delivery, and safety
Donnelly, R. F., Singh, T. R. R., & Woolfson, A. D. (2010) · Drug Delivery · doi:10.3109/10717541003667798 · Cited by 708
Polymer Microneedles for Controlled-Release Drug Delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-0028-9 · Cited by 493
Microneedles for intradermal and transdermal drug delivery
Tuan-Mahmood, T.-M., McCrudden, M. T. C., Torrisi, B. M., McAlister, E., Garland, M. J., Singh, T. R. R., & Donnelly, R. F. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2013.05.005 · Cited by 468
Metadata
- Authors
- Sivamani, R. K., Stoeber, B., Wu, G. C., Zhai, H., Liepmann, D., & Maibach, H.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2005-03-31
- Volume
- 11
- Issue
- 2
- Pages
- 152-156
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2063472013
- Cited by
- 171
- References
- 2
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.