A nonlinear elastic behavior to identify the mechanical parameters of human skin in vivo
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Background/purpose: Various analyses have been performed to identify the mechanical properties of the human skin tissue in vivo. They generally use different approaches and hypotheses (behavior laws as well as mechanical tests) and the obtained results are consequently difficult to analyze and compare. In this paper, an inverse method that can be adapted to any kind of mechanical tests and behavior laws is presented. Method: A suction deformation performed on the volar aspect of the forearm of a subject is considered. This test is modeled with the finite element method to compare the experimental and simulated curves using an inverse method that allows the skin mechanical parameters identification. This process is based on two optimization algorithms, Kalman's filter and Gauss–Newton's methods. To account for the nonlinear behavior of the skin, a specific nonlinear elastic law, which is then compared with standard linear elastic and neo‐Hookean's mechanical behaviors, was developed. Results: The obtained results first prove that neither linear elasticity nor neo‐Hookean's laws can be used to model the skin. On the contrary, the nonlinear elastic model presents a relevant fit of the experimental curves. The skin thickness is also proved to be another key point to be taken into consideration. Conclusions: The obtained results are successfully compared with literature and the reliability of the proposed method is underlined with the identification of 300 additional experimental curves. The different works we are currently focusing on are finally introduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Practical methods of optimization
(1988) · Mathematics and Computers in Simulation · doi:10.1016/0378-4754(88)90129-2 · Cited by 5,818
Lemaitre, J., Chaboche, J. L., & Maji, A. K. (1993) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1993)119:3(642.2 · Cited by 3,317
Mittelstedt, C. (2023) · Springer eBooks · doi:10.1007/978-3-662-66805-4 · Cited by 1,492
The Modified Gauss-Newton Method for the Fitting of Non-Linear Regression Functions by Least Squares
Hartley, H. O. (1961) · Technometrics · doi:10.1080/00401706.1961.10489945 · Cited by 845
[Mechanical properties of living tissues].
Sato, M. (1986) · PubMed · Cited by 516
A finite element formulation for nonlinear incompressible elastic and inelastic analysis
Sussman, T., & Bathe, K.-J. (1987) · Computers & Structures · doi:10.1016/0045-7949(87)90265-3 · Cited by 487 · cited 2×
“Nevertheless, Sussman and Bathe (37) propose a compressible potential for hyperelastic laws W ¼ X1ðJ1 3Þ þ ðk=2ÞðJ3 1Þ2, where k is the compressibility constant, J1 and J3 are the first and third reduced invariant of the modified right Cauchy–Green deformation tensor C ¼ I 1”
BackgroundViscoelastic properties of human skin and processed dermis
Silver, F. H., Freeman, J. W., & DeVore, D. (2001) · Skin Research and Technology · doi:10.1034/j.1600-0846.2001.007001018.x · Cited by 476 · cited 2×
“fluid (10, 19), the shear interaction between collagen fibers and the matrix of proteoglycans (4), and the dissipative friction of the fibers (6, 8).”
BackgroundHandbook of non-invasive methods and the skin
Guy, R. H. (1996) · Journal of Controlled Release · doi:10.1016/0168-3659(96)01365-x · Cited by 412
Mechanobiology of force transduction in dermal tissue
Silver, F. H., Siperko, L. M., & Seehra, G. P. (2003) · Skin Research and Technology · doi:10.1034/j.1600-0846.2003.00358.x · Cited by 380 · cited 2×
“(14) propose to identify the collagen stiffness, thanks to the third phase slope Fig.”
BackgroundIn vivo model of the mechanical properties of the human skin under suction
Diridollou, S., Patat, F., Gens, F., Vaillant, L., Black, D., Lagarde, J. M., Gall, Y., & Berson, M. (2000) · Skin Research and Technology · doi:10.1034/j.1600-0846.2000.006004214.x · Cited by 350 · cited 3×
“(21) have respectively found Young’s modulus about 250, 130 and 150 kPa.”
BackgroundMethodSelf-citationA numerical‐experimental method to characterize the non‐linear mechanical behaviour of human skin
Hendriks, F. M., Brokken, D., Van Eemeren, J. T. W. M., Oomens, C. W. J., Baaijens, F. P. T., & Horsten, J. B. A. M. (2003) · Skin Research and Technology · doi:10.1034/j.1600-0846.2003.00019.x · Cited by 347
Björck, Å. (1990) · Handbook of Numerical Analysis · doi:10.1016/s1570-8659(05)80036-5 · Cited by 313
Inverse finite element characterization of soft tissues
Kauer, M., Vuskovic, V., Dual, J., Székely, G. J., & Bajka, M. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00085-3 · Cited by 245
Dunn, M. G., & Silver, F. H. (1983) · Connective Tissue Research · doi:10.3109/03008208309005612 · Cited by 232
Delalleau, A., Josse, G., Lagarde, J.-M., Zahouani, H., & Bergheau, J.-M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.001 · Cited by 230 · cited 1×
“This method is divided into three stages (26).”
MethodSelf-citationBiomechanical 3-D finite element modeling of the human breast using MRI data
Samani, A., Bishop, J., Yaffe, M. J., & Plewes, D. B. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.921476 · Cited by 217
Finite element modeling of human skin using an isotropic, nonlinear elastic constitutive model
Bischoff, J. E., Arruda, E. M., & Grosh, K. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00018-x · Cited by 213 · cited 1×
“Many mechanical laws, which usually require complex backgrounds, have been analyzed to model soft tissues behavior in vivo (3, 4, 12, 19).”
BackgroundA mixture approach to the mechanics of skin
Oomens, C. W. J., van Campen, D. H., & Grootenboer, H. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90147-3 · Cited by 195 · cited 3×
“fluid (10, 19), the shear interaction between collagen fibers and the matrix of proteoglycans (4), and the dissipative friction of the fibers (6, 8).”
BackgroundModel of the viscoelastic behaviour of skin in vivo and study of anisotropy
Khatyr, F., Imberdis, C., Vescovo, P., Varchon, D., & Lagarde, J. (2004) · Skin Research and Technology · doi:10.1111/j.1600-0846.2004.00057.x · Cited by 189 · cited 3×
“The suction test The in vivo suction test (1, 5, 21, 22) consists of applying a negative pressure at the skin surface, S tr es s”
BackgroundMethodSelf-citationBiomechanical Properties of Skin
(2000) · Surgical Techniques for Cutaneous Scar Revision · doi:10.1201/9781420028591-6 · Cited by 174
Biomechanical Properties of Dermis
Daly, C. H. (1982) · Journal of Investigative Dermatology · doi:10.1038/jid.1982.4 · Cited by 165
Biomechanical Properties of Dermis.
Daly, C. H. (1982) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12544620 · Cited by 164
An In Vivo Method for Measuring the Mechanical Properties of the Skin Using Ultrasound
Diridollou, S., Berson, M., Vabre, V., Black, D., Karlsson, G., Conte-Auriol, F., Grégoire, J., Yvon, C., Vaillant, L., Gall, Y., et al. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00237-8 · Cited by 145 · cited 2×
“This hypothesis was also verified with ultrasounds imaging of the skin during a suction test (5), during suction deformation, subcutaneous structures do not affect the global response.”
MethodEEMCO Guidance to the in vivo Assessment of Tensile Functional Properties of the Skin
Rodrigues, L. (2001) · Skin Pharmacology and Physiology · doi:10.1159/000056334 · Cited by 145
Reihsner, R., Balogh, B., & Menzel, E. J. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)90856-7 · Cited by 142
Microanatomy of the Dermis in Relation to Relaxed Skin Tension Lines and Langerʼs Lines
Piérard, G. E., & Lapière, C. M. (1987) · The American Journal of Dermatopathology · doi:10.1097/00000372-198706000-00007 · Cited by 110
EEMCO Guidance to the in vivo Assessment of Tensile Functional Properties of the Skin
Pierard, G. (1999) · Skin Pharmacology and Physiology · doi:10.1159/000029897 · Cited by 108
Silver, F. H., Seehra, G. P., Freeman, J. W., & DeVore, D. (2002) · Journal of Applied Polymer Science · doi:10.1002/app.11119 · Cited by 106
Automatic measurement of dermal thickness from B‐scan ultrasound images using active contours
Lagarde, J., George, J., Soulcié, R., & Black, D. (2005) · Skin Research and Technology · doi:10.1111/j.1600-0846.2005.00108.x · Cited by 29 · cited 1×
“One-hundred and fifty tests were performed on 30 individuals, the thickness of the dermis for each experiment was measured using a high-frequency (20 MHz) ultrasound device (Dermcup, ATYS Medical, Soucieu en Jarrest, France) (32).”
MethodSelf-citationIn-vivo imaging of skin under stress: potential of high-frequency (20 MHz) static 2-D elastography
Mofid, Y., Ossant, F., Imberdis, C., Josse, G., & Patat, F. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1632683 · Cited by 22
Self-citation
Cited by
Skin mechanical properties and modeling: A review
Joodaki, H., & Panzer, M. B. (2018) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411918759801 · Cited by 480
Mechanical properties of whole-body soft human tissues: a review
Singh, G., & Chanda, A. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac2b7a · Cited by 364
Influence of epidermal hydration on the friction of human skin against textiles
Gerhardt, L.-C., Strässle, V, Lenz, A., Spencer, N. D., & Derler, S. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0034 · Cited by 334
Water‐Resistant Conformal Hybrid Electrodes for Aquatic Endurable Electrocardiographic Monitoring
Ji, S., Wan, C., Wang, T., Li, Q., Chen, G., Wang, J., Liu, Z., Yang, H., Liu, X., & Chen, X. (2020) · Advanced Materials · doi:10.1002/adma.202001496 · Cited by 235
Groves, R. B., Coulman, S. A., Birchall, J. C., & Evans, S. L. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.10.021 · Cited by 206
Metadata
- Authors
- Delalleau, A., Josse, G., Lagarde, J. ‐., Zahouani, H., & Bergheau, J. ‐.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2007-07-27
- Volume
- 14
- Issue
- 2
- Pages
- 152-164
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2052613878
- Cited by
- 164
- References
- 31
- FWCI
- 2.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.